Ksp Of Reaction Lab Report

Improved Essays
Introduction Although, in general, salts are known for their solubility, not all types of salts completely dissociate in water. Some of them partially dissociates and creates a dynamic equilibrium due to the instances when their ions recombine to form the original salts. An example of this is potassium hydrogen tartrate (KHC4H4O6 or KHT). When KHT is placed in water, it partially dissolves and forms K+ and HC4H4O6- ions. This reaction is shown below:
KHC_4 H_4 O_6 (s)⇄ K^+ (aq)+HC_4 H_4 O_6^- (aq)
(1)
The equilibrium constant of reaction (1) is written as Ksp or solubility product constant. The Ksp of reaction (1) is shown in the equation:
K_sp=[K^+ ][HC_4 H_4 O_6^-] (1) One of the purposes of the experiment is to determine the Ksp value
…show more content…
In the second part of the experiment, KHT was added to solutions of different potassium ion concentrations. Similar to the first part, the concentration of HC4H4O6- was calculated through titrations of 0.05 M KCl and 0.1 M KCl solutions with known NaOH concentrations. The total concentration of K+ for the solutions with the common ion is equal to the K+ concentrations from the KCl solutions and the K+ concentration from the KHT itself, which is equal to the concentration of HC4H4O6-. A scatter plot graph that compares the concentrations of K+ and HC4H4O6- for this part of the experiment is shown in the data below. Another purpose of the experiment is to determine the Ksp value of calcium hydroxide (Ca(OH)2). When Ca(OH)2 is placed in water, it partially dissociates to form Ca2+ and two OH- ions. This is evident in the reaction:
Ca(OH)_2 (s)⇄Ca^(2+) (aq)+2OH^- (aq)
(3)
The Ksp expression for reaction (3) is shown
…show more content…
One of the possible causes of this inaccuracy is the scale. In the experiment, the scale was used to measure the mass of KHP used in the standardization of NaOH. Since NaOH was used to standardize the HCl solution and to titrate the KHT in water, KHT in 0.05 M KCl, and KHT in 0.1 M KCl solutions, a slight inaccuracy in the measurement of the scale would cause a lot of errors in the whole experiment. In order to improve this, it is important that the scale used in the experiment is accurately calibrated. Aside from this, it is also necessary to perform the experiment in a more controlled environment, where external factors like the wind cannot affect the measurements of the scale. Besides the scale, the buret could have also caused some inaccuracies in the experiment. Most of the procedure in the experiment involves titration. Since the buret was used in the titration, it is important that the valves of the buret are tight enough throughout the experiment. This is because the valves are important in controlling the amount of NaOH or HCl being added to the solution being titrated. Any problems in the buret would cause inaccuracies in the volume recorded during the equivalence point. In order to improve this, it is important to utilize a more accurate buret with tight valves so the release of titrant is more controlled. Another possible source of error in the experiment is the filter

Related Documents

  • Improved Essays

    Equilibrium Reaction Lab

    • 507 Words
    • 3 Pages

    Using the calibration curve and the absorbance values for the reference solutions, the concentrations at equilibrium and as a result, the equilibrium constant can be found. The equilibrium constant for this particular experiment is a value representing the ratio of the concentration of FeSCN2+ ions at equilibrium to the concentration of Fe3+ ions and SCN- ions at…

    • 507 Words
    • 3 Pages
    Improved Essays
  • Improved Essays

    Iodine Reaction Lab

    • 492 Words
    • 2 Pages

    When preforming this experiment, we had our Run I value checked by our professors because we wanted to limit the chances of errors. All of the Run could have been affected is the solutions were not mixed properly because…

    • 492 Words
    • 2 Pages
    Improved Essays
  • Great Essays

    Slime Design Lab Report

    • 2025 Words
    • 9 Pages

    Systematic error: When adding water to dilute the sodium borate solution, the formula produced very precise numbers to two decimal places. These were impossible to measure accurately on a 50 cm3 measuring cylinder. This is an insignificant weakness. In future experiments providing more precise equipment. For example using a 1 cm3-measuring cylinder, which has markings of decimal places.…

    • 2025 Words
    • 9 Pages
    Great Essays
  • Improved Essays

    Vitamin C Lab

    • 1004 Words
    • 5 Pages

    A more accurate concentrated solution of KIO3 from Lab F would result in…

    • 1004 Words
    • 5 Pages
    Improved Essays
  • Improved Essays

    Anion Test Lab

    • 724 Words
    • 3 Pages

    After the reaction was carried out, the precipitate was separated by vacuum filtration, dried in the oven and weighed. The mass in grams of the expected precipitate when we started with five milligrams of potassium chloride should be similar to the mass of the precipitate we weight after it has been dried. If they are the same, this will help us confirm the identity of the reactants (the unknown sample 3) as well as its chemical properties and…

    • 724 Words
    • 3 Pages
    Improved Essays
  • Improved Essays

    Identifying Acid Values

    • 431 Words
    • 2 Pages

    Ka, or the acid dissociation constant, gives a measure to which an acid dissociates in a solution. It also provides a measure of the strength of an acid. If the value of Ka is high, the said acid s largely dissociated, making the acid strong. However, when the value of Ka is small, the little amount of acid is dissociated, making the acid weak. In the experiment, acetic acid (HOAc), is shown to have a computed Ka of 1.1148 x 10-5.…

    • 431 Words
    • 2 Pages
    Improved Essays
  • Improved Essays

    -Having a lack of accuracy in the measurement tools allows the results of the experiment to be distorted because once something is measured then one will have to round up or down resulting in estimation of results. This is a problem because ultimately the data will be different and follow the rest of the data trials that were conducted and will not follow certain guidelines. -The consequence of having a lack of accuracy is that once substances and/or materials are measured; there will be a lack in precision when rounding. And, by including microliter measurements on graduated cylinders, then measuring solutions will be more accurate due to having more measurement lines -The temperature of the liver solution and hydrogen peroxide were uncontrolled…

    • 548 Words
    • 3 Pages
    Improved Essays
  • Improved Essays

    Below is shown the equation for the dissociation of acetic acid into acetate. The experimental…

    • 1043 Words
    • 4 Pages
    Improved Essays
  • Improved Essays

    When my partner and I were done titrating we had to add NaOh solution until it turned from yellow to blue. We recorded the volume of the initial volume of the buret at 0 and the final at 2.8ml. My partner and I definitely made some errors. For example during part A we added more than 0.2 grams of the crushed antacid. This error caused the combined mass of the flask and antacid to be higher.…

    • 953 Words
    • 4 Pages
    Improved Essays
  • Superior Essays

    Sources of error  Quality of ingredients / raw materials: there maybe contamination or spoilage problem of the materials leading to an error  Equipment limitations/ calibration limitations: the pipette may not be calibrated properly or the instrument is unable to take measurement because of calibration…

    • 1103 Words
    • 5 Pages
    Superior Essays
  • Improved Essays

    Weak Acid Titration

    • 872 Words
    • 4 Pages

    The titration may have been ended too promptly, although this source of error can be ruled out by graphing the titration curve for each of the three trials. A lack of sufficient number of data points surrounding the equivalence point could have been an additional source of error. Despite sufficient data, the failing to properly standardize the pH meter could have affected the accuracy of the titration curve. Improper calibration of the machine would have only affected the accuracy of the data, and not the precision, demonstrated by the low standard deviation.…

    • 872 Words
    • 4 Pages
    Improved Essays
  • Improved Essays

    The pH meter may also have been a problem throughout the original experiment. In order to fix that, pH strips may have provided a more accurate measurement. Although pH strips are not very precise, they offer an accurate measurement in the area of the exact pH. Thus by using these strips, the pH data could have been more accurate. Another potential error that could have occured in this lab was the amount of stirring that was performed during the trials. There is no way to regulate how much stirring each trial experienced and thus, it could potentially become a source of error.…

    • 1215 Words
    • 5 Pages
    Improved Essays
  • Improved Essays

    Acid Base Titration

    • 738 Words
    • 3 Pages

    The concentrations are very precise, with an extremely small standard deviation. Error could have resulted from accidently going past the equivalence point of the reaction, after the indicator changed colors, or from an incomplete transfer of the acidic salt into the analyte solution. Discussion of Titration of Cola: The objective of part B was to calculate the pH of a sample of cola by titrating it with a known concentration of a strong base measuring the pH with a pH probe.…

    • 738 Words
    • 3 Pages
    Improved Essays
  • Great Essays

    Redox reactions involve the transfer of electrons, i.e. the loss and gain of electrons. KMnO4 is an oxidising agent which means it brings about oxidation and therefore it is being reduced. This means that the Fe (II) is the reducing agent and therefore is being oxidised. Carrying out a redox titration means for this experiment, using the average titre, which is determined by the colour change of the end point, it can determine: The moles of KMNO4 in the average titre, the amount of moles needed of Fe(II) to complete the reaction in 25cm3, using the Balanced equation for the reaction, from this the amount of Fe (II) in volumetric flask. Using these values the weight of Fe (II) can be calculated and then the % weight, respectively.…

    • 2461 Words
    • 10 Pages
    Great Essays
  • Improved Essays

    this value was obtained from the computer reading, where J is being a function of a° and has the following equation 31: J = σ1 Λo + σ2 (3) Where σ1 and σ2 are the functions of J. The derived constants are represented in Table 3. It can be seen from Table 3, that Λo values increase with increasing the temperature. The values of KA increase with increasing the temperature where the dielectric constant of solvents decreases with increasing the temperature as reported in literature (28-30) thus, Ion association occurs. The trend of KA in the present work was explained in the light of the U term as represented in the following equation 32: ln KA = ln (4 π NA ao 3 /3000) + e2 / aoDkT + U (4) Where U = ΔS / k – Es / kT (5) ΔS / k is the entropy Boltzman constant ratio which illustrates the probability of the orientation of the solvent molecules around the free ions and Es / kT is an energy relationship which includes the energy of the solvent molecules with respect to the free ions and ion-pairs.…

    • 935 Words
    • 4 Pages
    Improved Essays