List the four safety controls found on all hydronic systems |
Pressure relief valve high temperature limit switch low water cut off backflow preventer |
|
What is the normal operating pressure in a boiler |
12 to 15 psi |
|
What is the normal setting on the pressure release valve |
30 PSI |
|
Where is the pressure relief valve located |
Top of the boiler |
|
Where does the pressure relief valve discharge |
18 inches above the floor |
|
What is the common temperature setting for the high temperature limit switch |
210 degrees |
|
What is the purpose of the low water cut out switch on a residential boiler |
it will turn off boiler if water level drops which is dangerous because it can overheat the water crack the heat exchanger to put Steam in the pipes |
|
What is the safety control that prevents us from getting superheated water in a boiler system |
Pressure relief valve |