1.0 REFERENCES
1.1 Sample Preparation and Calculations for Dissolved Gas Analysis in Water Samples Using a GC Headspace Equilibration Technique, EPA National Risk Management Research Laboratory, RSKSOP-175, Rev.2, May 2004.
1.2 Light Hydrocarbons in Aqueous Samples via Headspace and Gas Chromatography with Flame Ionization Detection (GC/FID), Pennsylvania Department of Environmental Protection Bureau of Laboratories, PA-DEP 3686, Rev.0, April 2012.
1.3 Lange’s Handbook of Chemistry, 14th edition (1992), McGraw Hill.
1.4 Gas Encyclopedia, Air Liquide, online edition (2009).
2.0 SCOPE AND APPLICATION
2.1 Samples reported using this procedure reference the sample preparation SOP commonly referred to as “RSK-175” for use in West Virginia. The
…show more content…
Analytes are detected using a Flame Ionization Detector (FID). The amount of gas in the original liquid sample is directly proportional to the amount of gas in the headspace of a closed vessel.
3.2 Standards are prepared by saturating a solution of water with the gases, and making dilutions from that stock.
4.0 INTERFERENCES
4.1 Since these compounds are highly volatile, care must be taken during sampling to prevent agitation, creation of bubbles or headspace during storage. Transfer all samples quickly to the sampler vials while still cold, if possible.
4.2 Results are dependant on the headspace sampler conditions remaining constant.
4.3 Studies have not been done to determine the effect of differing matrices (chlorination, salinity) on solubility of the gases in this procedure. It should have little effect as the gases have a low partition coefficient.
4.4 Methane is a common contaminate and occurs naturally in the atmosphere. Analysis of a blank proves that the system is not
…show more content…
Each gas is prepared and calibrated separately.
8.3 The chromatography software performs all calculations for determining the calibration model (or fit). Average calibration factor represents the slope of the line between the response for each standard and the origin.
8.3.1 The variation over the range of the calibration must be less than or equal to 20% Relative Standard Deviation (RSD) to be considered linear.
8.3.2 Linear calibration using a least squares regression can also be used. The “goodness of fit” of the linear regression, given as r2 by the software, must be greater than or equal to 0.995.
8.4 Verify the calibration curve with an independent standard for each gas. The second source ICV must be within 20% of its expected value for each analyte.
8.5 Also examine the calculated value of the lowest calibration standard (MRL). This step is used to ensure analytes can be accurately reported at the quantitation limit or to demonstrate bias in the calibration model. If the value exceeds 50% of the expected value, inspect the curve for proper values, proper integration and identification, or ensure proper standards were

Related Documents

  • Improved Essays

    Kwong Equations

    • 1022 Words
    • 5 Pages

    The cubic Z-factor equation can readily be solved with an analytical or a trial-and-error approach. One or three real roots may exist, where the smallest root (assuming that it is greater than b) is typically chosen for liquids and the largest root is chosen for vapors. The middle root is always discarded as a nonphysical value. For mixtures, the choice of lower or upper root is not known a priori and the correct root is chosen as the one with the lowest normalized Gibbs energy, g*. where, gy=∑_(i=1)^n▒〖(ln⁡(〗 fi(y))*yi) gx=∑_(i=1)^n▒〖(ln⁡(〗 fi(x))*xi) where yi and xi = mole fractions of vapor and liquid, respectively, and fi = multicomponent fugacity But in RK EOS all components have a critical compressibility factor of Zc=1/3, where, in fact, Zc ranges from 0.29 for methane to 0.2 for heavy C7fractions.…

    • 1022 Words
    • 5 Pages
    Improved Essays
  • Improved Essays

    Alkalinity Lab

    • 846 Words
    • 4 Pages

    Detailed data is collected by adding small volume of acid titrant and recording the corresponding to the two equivalence points. Task 3 Alkalinity of natural water. 10 mL of 0.1M NaCl solution is added in a100 mL volumetric flask using natural water as diluent. Tree replicate of 50 ml of this sample is transferred into a beaker, and the same steps used to standardization are followed for each sample. Task 4: Alkalinity of natural water using Hach…

    • 846 Words
    • 4 Pages
    Improved Essays
  • Great Essays

    Continue recording even after cyclohexane is visually start forming solid ( you will need 5-6 measurements after you see solid in the large test tube.) 7. After you complete this part of the procedure, move large beaker down by releasing the clamps and exposing large test tube with frozen cyclohexane. Do not open the large test tube. Allow the cyclohexane to melt.…

    • 1578 Words
    • 7 Pages
    Great Essays
  • Improved Essays

    Water content : The American Society for Testing and Materials(ASTM) standard method D95 was used from ensuring the water content of the oily sludge. The oily sludge was heated with benzene(solvent) which co-distilled with the water in the sample in a fume cupboard .Condensed solvent and water were continuously separate and the water settled as the bottom layer. The condensed liquid containing water and hydrocarbon was transferred to a graduated cylinder. A water layer with higher density was at the bottom of the cylinder. The volume of the water was then used in calculating the water content in the sample (using the density of water of 1g/cm3 ).…

    • 935 Words
    • 4 Pages
    Improved Essays
  • Improved Essays

    The answer then is .0298 moles of gas produced. After the reaction, and an incision to release the gas, the mass also had to be identified, which was less than the previous mass, 255.9 grams. The experimental molar mass was 0.0894 grams, found by using the moles of 〖Co〗_2 and the masses. The percent yield came about by dividing the experimental molar mass by the theoretical (44.01grams) to create 20 percent. The percent yield shows how far off the experimental calculations were from the truth.…

    • 425 Words
    • 2 Pages
    Improved Essays
  • Great Essays

    Also the shortest tube was used to reduce systematic errors. Controlled Recording initial rate Amount of enzyme Temperature Volume of hydrogen peroxide solution Size and type of test tubes Hydrogen peroxide Cap the test tube immediately with the gas pressure sensor once the hydrogen peroxide is poured inside to be able to record the most accurate data. Be very carful when adding drops of enzyme because even the slightest drop can affect it completely. To have the most accurate measurements use micropipette and use 10 micro-liters of enzyme. Be sure to keep the room temperature at a constant rate of about 25C due to the fact that the rate of reactions is related directly to the…

    • 1608 Words
    • 7 Pages
    Great Essays
  • Great Essays

    The average of volume of NaOH used in the calculations was calculated as the average of the two best values which increases accuracy. The final pH of the titration can be altered if excess indicator is a added. Experiment 2: To prepare the solution of KIO3, the mass that must be added in 250 mL of distilled water must be calculated as shown; 1 mol of KIO3 is contain in 214.00g 0.005 mol of KIO3 1.07g Since the potassium iodate is only 99% pure 99% 1.07g 100% 1.081g Hence, mass of KIO3 used= 1.081g Apart from KIO3 and KI, sulfuric acid is also present in the conical flask, in excess, to provide H+ ions to increase the rate of reaction. 2.3 Conclusion After having done both experiment in the laboratory, we can conclude that he titration method relying on visual detection of the end point for quite precise determination of the unknown…

    • 1357 Words
    • 6 Pages
    Great Essays
  • Improved Essays

    Experiment 7 Electrophilic Aromatic Substitution Of Salicyamide Name: Lidia Santiana Palha Student number: s3333523 Email-address: lidiapalha@gmail.com Name of demonstrator: H.Helbert Reaction Equation Summary Salicylamide and sodium iodide are dissolved in ethanol, and stirred and cooled to 0. After that household bleach was added while stirring vigorously, solution changed from colorless to pale yellow. Sodium thiosulphate and hydrochloric acid were added aswell. Product collected by vacuum filtration and recrystallized from 96% ethanol. IR- and H- NMR-spectrum were taken to determine the location of the I+.…

    • 960 Words
    • 4 Pages
    Improved Essays
  • Improved Essays

    Isobutylene Research Paper

    • 1817 Words
    • 8 Pages

    The outlet feed stream from V2215 A/ B is routed to the filters (F2203 A/ B) to ensure that the feed stream supplied to the cold box is clean from dust and moisture. Isobutane that leaves the filters enters the cold box to produce a fresh stream of Isobutylene (C4H8) and Hydrogen (H2) rich recycle gas as shown in Equation (4). Finally, C4H8 and H2 pass through Hot Combine Feed Exchanger (E2201 A/ B) to be heated up before entering the three reactors that are connected in parallel (R-2201, R-2202, R-2203); Whereas the isobutane is converted into isobutylene by using the catalyst inside the three reactors.The percentage of the Isobutane that converted to Isobutylene…

    • 1817 Words
    • 8 Pages
    Improved Essays
  • Improved Essays

    Distillation Lab Report

    • 1011 Words
    • 5 Pages

    Once the fractional distillation setup is complete, the stirbar in the Erlenmeyer flask containing the binary solution is turned on to ensure homogeneous boiling. As the solution starts to boil, vapor containing the more volatile component travels upward through the column until the temperature gradient becomes too cool and it condensates on the side of the distillation column. The verticality of the column provides a surface area for the vapors to condense and flow back down the column until the temperature becomes hot enough for it to vaporize again. This process of re-condensation and re-evaporation continues until the vapor becomes purely the more volatile compound. Once at the stillhead, the pure vapor meets a water-cooled condenser that cools the vapor causing it to condensate and flow into a Falcon tube receiver.…

    • 1011 Words
    • 5 Pages
    Improved Essays