• Shuffle
    Toggle On
    Toggle Off
  • Alphabetize
    Toggle On
    Toggle Off
  • Front First
    Toggle On
    Toggle Off
  • Both Sides
    Toggle On
    Toggle Off
  • Read
    Toggle On
    Toggle Off
Reading...
Front

Card Range To Study

through

image

Play button

image

Play button

image

Progress

1/15

Click to flip

Use LEFT and RIGHT arrow keys to navigate between flashcards;

Use UP and DOWN arrow keys to flip the card;

H to show hint;

A reads text to speech;

15 Cards in this Set

  • Front
  • Back

Riding list is a list of members on duty. This list also shows?

Glossary. Riding positions, tools assigned, masks assigned and group numbers for each member on the list.

If a known life hazard is discovered and immediate action could prevent the loss of life, appropriate action ( rescue activity ) may be taken by an individual member. A known life hazard is define as what?

1.1 A victim can be seen by the rescuer, A victim can be heard by the rescuer, A member has info from a credible source or a person at the scene indicating the location of the life hazard.

In all incidents of such individual action, the IC shall forward a report detailing the full particulars to the?

1.1 Chief of operations

Tenements are__ to ___ wide.

1.2 20' to 25'

Tenements are___ to ___ deep.

1.2.3 50' to 85'

When the LCC is unable to position the aerial ladder for complete coverage who should he notify?

3.2.4.1 The IC and ladder company officer

When should the LCC of a aerial ladder remain on the turnable?

3.2.4.5 When members have entered the building by aerial ladder and are in precarious positions such as a floor over a heavy fire, the roof of a building with a heavy fire condition, etc.

How do you accesss the roof at a tenement?

3.2.6 BAR adjoining building, aerial ladder, rear fire escape

When should the roof FF immediately proceed to the bulkhead and perform vertical ventilation?

3.2.6.1 Unless addressing a known life hazard, upon hearing radio transmissions that the interior team has door control on the fire floor, or a charged hoseline is advancing into the fire apartment.

If the bulkhead door cannot be closed and controlled for any reason who should be notify?

3.2.6.2 Ladder company officer inside the fire area to be searched.

Does the roof FF need permission to vent a dumbwaiter shaft?

4.3.5 no

When the bulkhead door is used to gain access to the roof of a bulkhead drive the hook of the halligan into the roof. Then position the door against the bulkhead at an angle of?

5.3.3 30 to 45 degress

When the building has four windows per floor and no front fire escape it indicates?

5.4.1 Railroad flats with a rear fire escape. This does not necessarily apply to a corner building.

When the building has four windows per floor and a front fire escape it usually indicates?

5.4 Three or four apartments per floor with another fire escape in the rear.

In old law tenements, the infrequently used procedure, of going from front to rear apartments or vice versa through the common partition may also be used as an escape route. What tools shall be used to accomplish this?

6.1.1 Halligan, hook or axe. This is the order of preference.