What's is the minimum service clearance to the control side of a boiler?

18"

What type of furnace does the air discharge out of the bottom?

Down Flow

A unit heater requires a clearance to combustibles from the back and sides of?

6"

A category 1 appliance.....

Has a positive vent pressure

A condensing (heating) appliance will generally have a vent temperature of no more than?

125°f

The range of efficiency (seasonal) that applies to Category 1 fan-assisted heating appliances is?

78% - 83%

Rating plate efficiency does not take into account;

The Flame Quality

The minimum length of hose permitted for a construction heater is?

15ft

Flame rectification relies on the ____________ of the flame?

Conductivity

Typical spark ignition voltage for an IPI system would be?

10KV dc - 30 KV dc

On a flame safeguard system using flame rectification, the rectified signal is generally in the range of?

1-10 DC uA (Micro Amps)

The minimum spark gap for a IPI pilot assembly is?

1/8" Gap

The VA rating on a transformer indicates?

The capacity rating

Can a ECO on a commercial water heater can be bypassed?

No

If the high limit is installed on the primary voltage what does it control?

Transformer

After removing power, to isolate the 24 volt gas valve, you would use which type of meter?

Ohm meter

The Hugh limit on a forced air furnace is normally set between?

Between 180°f and 250°f

The fan control on a forced air furnace is generally set at?

130°F cut in


90°F cut out

Cut in and cut out

Air Supply includes?

Dilution Air


Excess Air


Combustion Air

A combustion air opening must be located?

No more than 12" above and 24" horizontally from the burner of the largest input appliances



&



No more than 18" and no less then 6" above the floor

Primary Air is defined as being?

The air mixed with the gas before it's ignited.

A ventilation air opening from a structure to an enclosure must be located?

No lower than the lowest draft hood appliance



&



As high as practical

Excess Air volumes are accurately measured by?

In the flue gases of the heat exchanger

Automatic motorized combustion air louvers must be?

Interlocked with the gas valve

The total height for a vent or common vent is measured from?

The highest draft hood outlet to its termination



&



The same as you would measure the total chimney height

The minimum effective vent height of Type B vent is _____ ft?

5'

The minimum gauge material allowed in a vent connector is?

28

GSG

What is the smallest vent allowed in a venting system?

3"

What is the minimum clearance a heater in a storage garage can be installed from combustibles?

18"

A residential gas dryer is never to be vented into?

To the inside & to a vent system serving other appliances

The valve that must be on all propane cylinders is?

Relief valve