Forced air system heating heat the space from where to where? |
From the ceiling down |
|
Baseboard heating Heats through? |
Convection |
|
Fin baseboard is made of three components? |
Copper tube aluminum fins and enclosure |
|
Radiant Heating Heats what |
Surrounding surfaces |
|
Advantages of radiant floor heating over conventional forced air? |
•Lower temperature stratusfaction, •minimal air movement •and higher surface temperatures of objects in the room. |
|
How is the response time for radiant floor heating? |
Slow |
|
Radiant floor heating systems don't allow for? |
Air filtering, purification or humidification. Systems must be installed to maintain air quality. |
|
Applications for radiant Heating? |
Residential, commercial, industrial, snow melt, Agriculture and sports field applications. |
|
Three categories of tubing for radiant floor heating? |
Metallic, synthetic and composite. |
|
The ability of oxygen molecules to pass through a material? |
Oxygen permeation. |
|
Composite tubing consists of? |
PE/AL/PE A thin layer of aluminum sandwiched between two layers of plastic. |
|
Recommended length for 3/8" copper? |
250' |
|
Recommended length for 1/2 inch copper? |
300' |
|
Recommended length for three quarter inch copper? |
500' |
|
The rule of thumb recommended flow rate for residential? |
2 to 4 feet per second |
|
Recommended floor temperature four areas where people stand? |
77 °f |
|
Recommended floor temperature in dwelling or commercial spaces? |
88°f |
|
Recommended floor temperature in bathrooms, swimming pools, and for foyers? |
91 °f |
|
Balancing valves are not required if there is less than what percent difference between the longest and shortest circuit? |
10% |
|
With heat loss calculations you must round up to the nearest? |
.25 / quarter inch of a foot |
|
DTD is the difference between? |
Your IDT and your ODT |
|
Transmission loss? |
Conduction through a material |
|
For heat loss calculations what percent must be added for bathrooms? |
20% |
|
R value is? |
The resistance to flow. IE- window. Wall. Or combination of products. |
|
What requires you to know the pressure drop through a system, gallons per minute required and temperature drop through the circuit? |
Pump sizing |
|
Where is the lowest pressure point in a pump and in radiant floor heating systems? |
At the inlet of the pump |
|
Where is the best location for a pump? |
At the point of no pressure change. |
|
What is required in order to properly size a boiler for an application? |
Total heat load required for the building |
|
What recommendations should be followed when installing boilers? |
Manufacturer's recommendation |
|
What type of boiler is best suited to Supply heating water directly to an in floor heating system? |
Condensing boiler |
|
How many BTUs in one pound of water |
970 BTUs |
|
Conventional boilers must operate at what temperature? |
Above 140°F |
|
Condensing boilers operate at what temperature? |
Below 140 °F |
|
What is the greatest advantage of hydronic heating over any other system? |
Multiple zoning |
|
Which one of the following floor coverings has the greatest R-value? A) hardwood B) ceramic tile C) vinyl tile D) carpet and underlay |
C) vinyl tile |
|
What three factors must you know in order to size tubing? |
•Gallons per minute flow rate, •length of the circuit and •design temperature drop through the circuit. |
|
A typical velocity in a residential application is between? |
2 and 4 feet per second. |
|
In a piping layout how much temperature drop is there across a circuit? |
15 to 20 degrees across the circuit |
|
Good practice is to install tubing along an exterior wall at what spacing? |
6" |
|
The counter flow pattern is used when heat loss is? |
Evenly distributed |
|
Tubing should be fastened every? |
3 feet and on arches |
|
What three factors must be known in order to properly size tubing for an application? |
GPM, velocity and length of circuit |
|
What is the required minimum measurement when a pressure test is on for a radiant floor heating system? |
The greater of either 60 PSI or 1.5 x working pressure for 1 hour |
|
What two factors are required to calculate header size? |
GPM and velocity |
|
What is required when piping a low mass boiler that is flow sensitive? |
A bypass pump between the supply and return boiler piping |
|
What is required when a conventional boiler is installed in a low temperature radiant floor heating application? |
A mixing valve |
|
What is the first step in servicing a boiler venting and Main burner? |
Turn off the electrical and gas supplies |
|
What is the best way to clean a main burner? |
Vacuum and soft brush |
|
What type of thermostat is used on a hot water heating system? |
A thermostat without a heat anticipator. |
|
A loose wire on an aquastat may? |
Prevent to the main Berner from firing. |
|
What will happen to a non-condensing boiler when the return water temperature is too low? |
There will be unnecessary damage and boiler failure. |
|
What is the code for hydronic heating systems? |
B 214 |