Who is responsible for making sure that there is a supply of water for fighting fires?

Water Authority

What are the 3 British Standards for Hydrants?

-65mm round thread outlet


-2000 LPM at 1.7BAR


-Opens anticlockwise

How should a hydrant be opened?

Slowly and Fully

What are the uses of a Hydrant Plate?

Give direction to the hydrant, and indicate the size of the water main attached.

Hydrant Gear...

-Standpipe


-Hydrant key


-Hydrant bar


Why should a visual inspection of a hydrant be undertaken on a yearly basis?

-To check condition of the hydrant.


-To familiarise with the location of the hydrant.

What are the safety precautions when disconnecting a hose from the standpipe?

-Helmet visor down


-Grip hose on top of male coupling


-Feel hose to make sure pressure is released

3 answers

What should be done when a screw on leak detection device has been removed?

-Should not be refitted


-Water office informed


-Device left at the bottom of the pit

3 answers

What are the 4 diameters of lay-flat hose?

-45mm


-70mm


-90mm


-150mm

How many lengths of 70mm and 45mm hose on pump and pump ladder appliances?

45mm - 4 lengths


70mm - 10 lengths


(50% reserve at station)

45mm hose stats...


Length?


Weight?


Max pressure?

23 metres


9kg


Max pressure 15 bar


70mm hose stats...


Length?


Weight?


Max pressure?

23 metres


15kg


Max pressure 15 bar

90mm hose stats...


What appliance is it on?


How much is on the appliance?


What colour is it?


How long and heavy is it?


Max pressure?

-Carried on hose laying unit


-4km on appliance


-Yellow


-30 metres


-23.5kg


-Maximum pressure 15 bar

What are the different lengths of 150mm hose?

50 metres


10 metres


5 metres

Hose reel facts...

-Stored in coil drums, one on each side of appliance.


-Internal diameter 22mm


-18.3 metres, 4 lengths per drum

-storage


-diameter


-length

Hard suction hose facts...

-Lifts water from an open water supply such as river/lake


-2.44 metres long


-100mm diameter


-2 on each appliance

-Function


-Length


-Diameter


-Quantity

Define "Delivery Hose"...

45 and 70mm hoses are called delivery hose when delivering water from pump to fire

Define "Soft suction" hose...

70, 90 and 150mm hose can be called soft suction, when supplying a pump from a pressure fed supply, such as a hydrant.

Couplings on the 45 and 70mm hose are known as what?

Quick release instantaneous coupling.

-Made up of two sections, male and female.


-Full PPE should be worn, red dots in line, and water supply switched off to disconnect coupling.

When is a storz coupling used?

Between a 90 and a 150mm hose

-Interlocking with spanners

To prevent damage to a hose, the following 5 steps should be taken...

-Ramped when laid across road.


-Not kinked under pressure.


-Not made up when frozen.


-Under run before stowing.


-Rotated between appliances and reserve store every 3 months.

How is a 45 and 70mm hose stored on an appliance?

Dutch rolled

What is the test frequency of a hose? And what does the test consist of?

-On acceptance


-After operational use


-Annually



1 length at 15 bar for 1 minute.


7 bar inspection

Delta Attack 400-S-Pro and Rosenbauer Select Flow Rb101 flow rates?

130lpm


230lpm


300lpm


400lpm

Delta Attack 400-S-Pro stats..

Effective throw at 6 bar 400lpm - 40 metres


Optimum working pressure at 6 bar for all rates.


Operating range is 5-8 bar

What is the flow rate of a Rosenbauer Projet II at 3.5 bar?

Spray - 290


Jet - 440


Both - 640

What is the flow rate of a Rosenbauer Projet II at 7 bar?

Spray - 410


Jet - 630


Both - 930

What are the flow rates of the Delta Attack 100-S-Pro?

50lpm


100lpm


150lpm


230lpm

What are the 4 measures to control jet reaction?

-Adopt a position on even and stable ground.


-Start with a managable pressure and increase.


-Have at least 2 FF on the branch when working with high flow rates & pressures.


-Hose in a straight line behind operator.

When is a ground monitor used

-Water on an area for a long period of time.


-Large amount of water is required


-Throw water further


3 answers

What is the maximum flow rate of the Akron Ground Monitor?

1900lpm

What is the function of a hosereel adaptor?

Enables a length of hosereel or hosereel branch to be connected to a standard 65mm instantaneous outlet.

Deluge Vs Foam Vs Variable nozzle flow rates..

Deluge - 1750lpm


Foam - 950lpm


Variable - 950 - 1400 - 1900lpm

Process of water from source to appliance...

-Resevoir


-Treatment works


-Pumping station


-Trunk main


-Service main


When are Hydrants tested and inspected?

Tested every four years


Visually inspected annually between April and September

Delta Attack 100-S-Pro


Flow rates, handle and grip, coupling

Delta Attack 400-S-Pro


Flo rates, grip and handle, jet reaction, optimum flow rate, coupling

Rosenbauer Projet II

Akron Mercury Ground Monitor

What kind of coupling is on 45mm and 70mm Hose?

Quick release instantaneous coupling

What is a lay flat hose made of?

Duraline High Grade Synthetic Rubber, Extruded through polyamide woven jacket

Requirements of Hose...?

-Reliable.


-Durable.


-Resistant to burst, chemical and kinking.


-Light and easy to handle, make up wet and dry.


-Smooth internal to reduce frictional loss.


-Withstand pressure change.


-Stretch 5% in length, 10% in diameter.


7 requirements

What is the pump used on an LFB pumping appliance?

Godiva 3010 Prima Series Multi Pressure pump, producing 3000lpm at 10 bar pressure, with a 3 metre lift.

What is the water and foam capacity on a pumping appliance?

1365 litres of water.


80 litres of foam.

Define pump...

A pump is a machine, driven by external power, to give energy to fluid.

What are the types of pumping appliance?

-Pump (crew of 4)


-Pump Ladder (crew of 4)


-Dual purpose pump ladder at 1 app station (crew of 5)

Appliance inventory checks are carried out for what 3 purposes?

-To make sure all equipment is present.


-To check condition and readiness.


-To check that equipment is correctly stowed.

"Stop"

"Danger"

"Move to attendants right"

"Move to attendants left"

"Move towards attendant"

"Horizontal Distance"


Indicates distance between appliance and another object.

"Move away"

What are the two parts making up a single stage Centrifugal pump?

-The impeller


-The volute

Describe an impeller...

The rotational element of the pump, imparting kinetic energy into fluid.

Describe a volute...

Converts kinetically charged fluid from the impeller, to pressurised energy due to the confined space in the volute casing.

Describe P.T.O

Power Take Off.


-Road engine power is diverted from road wheels, to the pump drive shaft.


-Prior to PTO engagement, the handbrake should be on an neutral engaged, and PTO placed into stand by.

What extra feature does a multi stage pump have that a single pump doesn't?

A peripheral impeller, allowing for high and low pressure simultaneously.

The Godiva 3010 prima series multi pressure pump is a 2 stage Centrifugal pump, so can be used to...

-Supply high volumes of water at low pressure.


-Supply low volumes of water at high pressure.


-Supply low and high pressure simultaneously.


What are the main controls in the pump bay?

-Hydrant to tank auto fill valve.


-Tank to pump valve.


-Low pressure delivery valve.


-High/Low pressure lever.


-Hosereel isolation valve.


-Emergency engine stop switch.


-ePump Control screen. (EPC)

7 controls

What is the primary function of the High/Low pressure valve?

Controls flow of water to the peripheral impeller.

What are 5 ways to counteract overrunning the appliance?

1- Find a better water supply


2- Shut down unnecessary jets


3- Reduce flow rates


4- Reduce pressure


5- Withdraw from building

Advantages of using the low pressure valve..?

-Reduce noise


-Reduce emissions


-Reduce fuel consumption


-Reduce overheating

Akron ground monitor stats

What is the ratio between high to low pressure?

5:1

How many male couplings are on a collecting breach?

2 male, one female.

Pressure loss calculations:

70mm - 0.2 bar loss per length


45mm - 1 bar loss per length


Hosereel - 6 bar loss per length



1 upward metre - 0.1 bar loss


Every floor - 3 metres.

What are the factors affecting pressure loss?

MAIN TWO


-Internal diameter of hose


-Height in metres above/below water source



ALSO


-Output flow of water


-Length of hoseline

4 factor

What sort of lip do you find on the male part of the instantaneous coupling?

Annular lip

What is a drain boss, and what is it commonly known as?

A frost valve, drains excess water to prevent freezing and cracking.

What types of hydrant plates are there?

Standard, Double and Directional

What kind of coupling is on a stand pipe?

Pressure release coupling

What type of knot do you put in each length of a damaged hose?

Overhand

How often should a hose length be tested?

-On acceptance


-After operational use


-Annually

On the Delta Attack 400 - S - Pro, when do you require 2 FFs?

When going 300lpm flow rate or above

When does a branch require replacing?

When it's missing 5 teeth overall, or 3 in a row.

What are the different adaptors found on an appliance?

-Dividing breeches


-Collecting breeches


-Hosereel adaptor


-90mm hose adaptor kit

What does number one shout at the end of a drill?

"Drill complete, all gear made up Gov!"

Hydrant set up commands...

-"Hydrant Ready"


Said by hydrant operator when hose attached to hydrant.



-"Water on the hydrant"


Said by pump operator with raised fist, and repeated by hydrant operator.

Hydrant make up commands...

-"Knock off hydrant"


Said by pump operator and repeated by the hydrant operator, with sweeping hand movement away from body. Hydrant supply of water is then switched off.



-"Release hydrant pressure"


Said by the hydrant operator, and repeated by the pump operator.


-"Hydrant pressure released"


Said by pump operator and repeated by hydrant operator. Dismantling the hydrant can then commence.


6 factors that affect lifting from open water...

OFPITA


-Over coming inertia, energy used to get the water moving.


-Frictional Loss, while moving up the hose, frictional loss occurs.


-Pump entry loss, the eye of the pump takes energy from the water.


-Imperfect vacuum, a perfect seal outside laboratory conditions is impossible.


-Temperature of water affects the lift of water.


-Atmospheric pressure decreases with altitude.