Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
22 Cards in this Set
- Front
- Back
(208) Which analog multimeter control do you use for ac/dc voltages, current, and resistance measurements?
|
The function switch
|
|
(217) What digital storage oscope circuit compensates for high sampling rates of high frequency signals?
|
charged coupled device
|
|
(217) What type of sampling does a digital storage oscope normally use on a single shot or seldom-occuring signals?
|
Real-time
|
|
(217) What type of interpolation does a digital storage oscope use to measure pulse waves?
|
Linear
|
|
(217) What digital storage oscope button controls all waveforms displayed in the store mode?
|
Cursors control
|
|
(217) In acquiring a 4k record length on a digital storage oscope how many samples can you view at one time?
|
1000
|
|
(218) What is the purpose of the bit error rate test set?
|
To provide a bit error detection system that can determine the received data quality.
|
|
(218) What test equipment item provides a patterned digital test signal for loop testingand compares an identical pattern to determine the loop data quality?
|
BERTS
|
|
(218) Which of these is a major section of the typical bit error rate test set?
a. Analog signal generator. b. External clock generator. c. Internal clock generator. d. Bit synchronizer and error counter. |
b. Internal clock generator
|
|
(228) which spectrum analyzer control selects the maximum input level of the analyzer and reduces input signals to an optimum level?
|
min rf atten db
|
|
(230) when the display section of a frequency counterreceives the first ten pulses passed from the sigan l gate, what is sent from the first decimal counting unit to the second decimal counting?
|
a carry pulse
|
|
(230) which of the following is not an application of a frequency counter?
a. Monitoring transmitter frequencies. b. Monitoring bit clock frequency. c. Monitoring transducer outputs. d. Monitoring FM drift. |
c. Monitoring transducer outputs.
|
|
(200) Where are the explicit operating instructions for test equipment, and which TO tells you where to find further information?
|
Applicable technical orders; 0-1-33-1
|
|
(200) Repair and calibration of test equipment is the responsibility of the...
|
Test measurement and diagnostic support center.
|
|
(200) Repair and calibration of test equipment is the responsibility of the...
|
Test measurement and diagnostic support center.
|
|
(200) Repair and calibration of test equipment is the responsibility of the...
|
Test measurement and diagnostic support center.
|
|
(200) When can a shop standard be used for routine maintenance functions?
|
If an emergency condition exists and like test equipment is inoperative.
|
|
[200]What is the best way to verify an indication given by a piece of test equipment?
|
make a comparison with a similar piece of equipment
|
|
[200] what internal device does some test equipment use to eliminate moisture?
|
built in heaters
|
|
[200] what should be done to test equipment when it is not in use
|
should be put in a cool dry place
|
|
[200]why must you unsolder one side of a resistor before making a measurement
|
to prevent erroneous readings
|
|
[200] list two precautions you should take before making a resistance measurement
|
remove power to circuit under test and disconnect any meters tubes and transistors that could be dmamged by the meter
|