The fuels training supervisor should review all training records |
Semi annually |
|
What form should be completed for awarding skill levels when all upgrade training requirements have been met |
AF Form 2096 Classification on the job training action |
|
Who is responsible for establishing a fuels mobility support element at locations storing or using mobility support equipment |
Fuels management team |
|
At least how many days before the due date must flight physicals and psychological training for Forward area refuelling point and aerial bulk fuel delivery system trained personnel be scheduled |
45 |
|
Maintaining a current listing of all personnel with special experience identifiers is the responsibility of the |
Fuels mobility supervisor |
|
Providing supply and equipment budget forecast through the fuels management team to the squadron commander is the responsibility of the |
Fuels support |
|
For a trend analysis who defined what constitutes a negative trend and develops policies to isolate and correct them |
Fuels management team |
|
Who should maintain the keys to the quality control holbox |
Laboratory personnel |
|
Who is responsible for administering the caution tag program |
NCOIC fuels laboratory |
|
When performing lock out and tagout procedures what form would you use to temporarily identify a condition that could result in a mishap that would cause death disability or a lossed workday mishap |
AF form 979 Danger Tag |
|
When reviewing test results in the fields Magar defence quality control application how our results not within parameters identified |
Failed status |
|
When entering sample information in fuels manager defense what information is automatically prefilled in the family SAMPLE block |
The next sequence sample number |
|
When recording test results which fuels manager defense Application would you use to track sampling dates and store sample results |
Quality control application |
|
What American society for testing in material methods are used to determine freeze point of aviation fuel |
ASTM D2386 or ASTM D5972 |
|
The temperature of the fuel in the aircraft tank normally decreases during flight depending on all of these factors except |
Aircraft type |
|
Is your base has experience cold weather problems or anticipates cold weather problems you should perform a cloud point test on all DF2 that is received during |
October through March |
|
During a flashpoint task apply heat to the sample so the temperature of the sample increases |
9 to 11 Fahrenheit per minute |
|
What is the normal range of use limits for fuel system icing inhibitor in turbine fuel |
0.04 to 20 percent |
|
How often should the aqua glow water detector be calibrated |
Daily |
|
When performing a fiber test on fixed vessels what action would be necessary if 2 successful Samples exceed 10 fibers per count |
Filter elements must be replaced |
|
A conductivity probe is not required to be cleaned before use when the |
Metre can be zeroed |
|
What type of container must not be used when performing connectivity test |
Plastic |
|
What is the preferable time after obtaining a sample to take a conductivity reading |
Two minutes |
|
What is a maximum out of time that can pass between the time a sample is obtained and the Time a conductivity reading is taken |
24 hours |
|
When should you calibrate a refractive metre that is used for fuel system icing inhibitor test |
Daily or when changing test water |
|
When performing a fuel system icing inhibitor test how long should shake the fuel and water mixture in the separatory funnel |
Five minutes |
|
What size graduate cylinder is used to perform the American petroleum institute gravity test |
1000 ml |
|
Where is the correct place to take the reading for the American petroleum instant to gravity test |
Horizontal plane surface of the liquid |
|
What do you use to rinse new sample containers prior to use |
Filter turbines fuel |
|
When performing the bottom at the test the flow reduce or ring is not used for testing what type of fuel |
JP5 |
|
To obtain meaningful results with the bottle method test the vacuum must read in excess of how many inches of Mercury |
20 |
|
What step must you take if a sample fails either colour or particulate assessment |
Take an immediate recheck sample using a matched weight monitor |
|
What type of Dye used for the aeronautical engine laboratory detector pad (AEL) |
Sodium fluorescein |
|
How often are the printed standards for the aeronautical engine laboratory test replaced (AEL) |
Annually |
|
How often do you test a liquid oxygen generating plant for odour and purity if a lox production run will exceed 24 hours |
Every 24 hours |
|
How often do you sample cryotaters for purity odour and minor constitutes |
Every 90 days |
|
How often should Fuel correlation samples be submitted to the area laboratory to check the accuracy of test performed at base level |
90 days |
|
When shipping a fuel sample what supply priority should be used for correlation samples |
09 |
|
Which recoverable and waste petroleum product category covers motor crank case oil and reciprocating aircraft engine oils |
Category three |
|
The American petroleum institute gravity test is most accurate when the fuel temperatures near |
60゚F |
|
When performing fuels controller duties in the event of an emergency you must notify each element in the fuels management flight the squadron commander and the |
Wing command post |
|
When determining authorizations for sales to non dod aircraft you know that T department of defence address activity codes are assigned to non dod organisations by |
Defence logistics agency energy DLA-Energy |
|
While attempting to determine authorizations for sales to non deal the aircraft you are unable to verify organisation as a valid authorised customer after reviewing the customer validation listing who should you responsible officer terminal manager contact 1st for assistance |
Business system modernization energy BSME help desk |
|
When in coding vehicle identification link keys how should you maintain copies of a veil key request in the defence fuel support point document control file |
36 months |
|
When encoating a vehicle identification link key for a rental vehicle what information should be entered in the vehicle identification field |
The vehicle licence plate number |
|
Regarding vehicle clipboards what is the colour of coding requirement for E85 ethanol |
Red clipboard with blue stripes |
|
Who is responsible for enforcing radio transmission discipline over the radio net |
Fuels controller |
|
The amount of petroleum war reserve requirement defence fuel supply point is authorised to store is referred to as |
Petroleum war reserve stock |
|
The war consumable distribution objective is derived from the war and mobilisation plan 4 and 5 |
Quarterly |
|
What agency prepares the war consumable distribution objective |
Major command |
|
When entering in order in the paperless ordering and received tracking screen system you can identify capitalised contracts as those listed in what colour text |
Purple |
|
When entering in order into the papers already received tracking screen system what agencies receive fuel request emails from after you have placed the ground product order |
The vendor and DLA energy |
|
When maintaining defence logistics agency energy files at a minimum the defence fuel supply point inventory transaction document in official records the store locally should consist of the current physical year documents plus documents from how many previous physical years |
2 |
|
When maintaining defence logistics agency energy files upon successful completion of end of year close out actions how long should you retain the 12 month electronic backup disc as the physical year backup |
6 years and 3 months |
|
When viewing the field manager to phan's product movement tracker alarm toolbar you see a flashing green colour in the alarm indicator Box you know this indicates |
In unacknowledged alarm condition has returned to normal |
|
Which method of payment is not authorised for a cash sale purchase |
Credit card |
|
When determining authorizations for cash sales you know that cash sales are only authorised when |
Sell support by equipment and/or personnel do not interfere with military operations |
|
Who must establish procedures for the collection safekeeping and deposit of funds received for cash sales of aviation fuels |
Fuels management team |
|
At no time will money that is collected for cash sales of aviation products be safeguarded by |
Off duty personnel |
|
When investigating fuel gains and losses you know that variances in inventory levels may be caused by any of the following conditions except |
Tank size |
|
When investigating fuel gains and losses you determine excessive variences caused by pipeline rupture ghis varience should fall to what category |
Peace time losses |
|
The inventory management plan is published |
Annually |
|
Who is responsible for maintaining the fuels account as outline according to DLA energy policies |
Fuels service centre |
|
When operators dispatch to complete a fueling operation which information is not provided |
Name of the requester |
|
When you are in putting a transaction in the FMD dispatch module what information should you enter in the request type when entering a defuel request |
Select defuel instead of the defaulted refuel |
|
When you are performing fuels controller duties how often should you reconcile with the fuels enterprise server and clear rejects |
Daily |
|
When you reconcile accounts what is the allowable tolerance for automotive gasoline |
.005 |
|
Who is responsible for reviewing aircraft flying schedules and organising work shifts to be fuel support requirements |
Fuels operations superintendent |
|
witch agency can initiate a joint chiefs of staff 's repo report |
Joint staff |
|
The tank group window in the fuels manager defence product movement tracker allows operators to create tubular list of up to how many tanks |
Twenty |
|
What agency access apartment of defence central procurement agent for bulk petroleum natural gas coal and associated services |
Defence logistics agency energy DLA-Energy |
|
What agency serves as a link between the defence logistics agency energy and its customers |
Defence logistics agency energy regions |
|
Which Air Force petroleum agency division performed contracting support for all AFPA contracted and cost recovery programs |
Resource management division |
|
Which Air Force petroleum agency division develops and evaluates emerging laboratory testing technology |
Laboratory division |
|
What agencies responsible for formulating in disseminating instructions and other directives that cover operations not specified in detail in DE LA energy policy or command policies |
Major command fuels office |
|
Who ensures complete accountability and responsibility for the handling of bulk petroleum And missile fuels at each Air Force base |
Fuels management team |
|
When reporting monthly assessment results what form do quality control evaluators use |
AF form 4421 logistics readiness squadron quality assurance assessment form |
|
What organisation May authorise basis to use computer products in lieu of AF form 2419 and 2420 |
Parent major command |
|
What agency should the field management team consult with on all matters regarding the provision of or changes to personal protective equipment for workers |
Base bio environmental engineer |
|
What outside agency collects and analyses and publishes based fuel mishap reports and develops trend analysis on reports affecting fuels operations |
Air Force petroleum agency |
|
When posting changes to publications when if ever our list of affected pages checks mandatory |
When changes and revisions are posted to paper TO's |
|
When posting changes in supplements to publications within what maximum number of work days I received should you file technical order changes and supplements |
Five |
|
What environmental regulations establishes cradle to grave control of hazardous substances |
Resource conservation and recovery act RCRA |
|
At a minimum under ground storage tanks should be monitored to detect releases every |
30 days |
|
How often should dikes be check for deterioration |
Weekly |
|
When conducting internal inspections at a minimum the logistics brightness squadron quality assurance office inspects each fuel element at least once |
Each 6 months |
|
Call spot checks are rated as |
Pass or failed |
|
Regarding vehicle clipboards what is the colour coding requirement for Jet A fuel |
Yellow clipboard with white stripes |