• Shuffle
    Toggle On
    Toggle Off
  • Alphabetize
    Toggle On
    Toggle Off
  • Front First
    Toggle On
    Toggle Off
  • Both Sides
    Toggle On
    Toggle Off
  • Read
    Toggle On
    Toggle Off
Reading...
Front

Card Range To Study

through

image

Play button

image

Play button

image

Progress

1/19

Click to flip

Use LEFT and RIGHT arrow keys to navigate between flashcards;

Use UP and DOWN arrow keys to flip the card;

H to show hint;

A reads text to speech;

19 Cards in this Set

  • Front
  • Back

List the different types of panels that can be found in the Anzac msb and give an brief explanation of each

-generator control panel ability to start, stop, connect and parcel ships gennys


-shore control panel used to connect shore to the main bus


-main feeder panels house c/b that feed equipment or distribution panels


-consumer panels houses that feed load centers and distribution boards


-bus bar linking bar houses the cb for the bus bar

Con the cbb, unit A1 controls the settings for three adjustable protective functions, what are they?


-under voltage relay


-instaneous short circuit trip


-thermally deployed over current trip

List three possible current ratings of a cbv

315a 630a 1000a

What are the main differences between a consumer circuit breaker and other types of MSB breakers

Ccb cannot be racked out and ccb can only be closed manually by the MSB operator, the c and m system only monitors them

What equipment controls the load shedding and reverse power protection operation of equipment in the MSB

Genop

What is the common name of the synchronizing lamps control unit

Sag 21

What equipment is used to prevent nuisance tripping of a cb and state it's tike duration and voltage level

Time delay unit, voltages under 75% or rated voltage. 1 second deplay

What is the SFIG 22

Automatic frequency adjuster and closing pluse transmitter

What is the main difference in the operation between the pig21 and the sfig22

Semi automatic and manual

List the four main components of the UPS system contained in a 24v DC panel

-diode blocking unit


-mains rectifier


-charging rectifier


-batteries

What is the purpose of the main rectifier

Transforms the 400v from the polygon transformer into 24v DC

Give a brief description of the diode blocking unit

Controls the charge of the battery and directs power to the consumers, either the mains or battery's

How many panels may a load centre have and what voltages can be expected to be contained

7 panels


440v 60hz, 440v 400hz, 240v 60hz, 115v 60hz, 115v 400hz, 24 DC

How many main load centre's are located on an Anzac frigate

13

When connecting bonding cables, when should earth straps be connected and disconnected with regards to shore power?

Before shore power is connected and after it has been disconnected

Why is their a need to bond ships to earth alongside

So that the ship and shore has the same potential difference removing the risk of electric shock

What is the nzbr the contains basic shore power reference

Nzbr 2020


Nzbr 2052

What do the sag 21 lamp configuration mean

Bright flashing - frequency different


Bright steady - frequency identical, phases different


Dim glowing - frequency identical, phases identical

Explain an alternator

-prime mover begins to rotate


-residual magnetism induces current jn exciter windings


-3 phase diode rectifier rectifies Ac-Dc for main field winding


-Ac current is induced into main sator winding for 3 phase output


-3 phase is tapped off and fed back to exciter for voltage regulation