What is Supervisability?

Supervisability is the ability for a fire alarm system to monitor itself.

Monitor ________

What sets fire alarm systems apart from other electrical systems?

Supervisability

That it has the ability to monitor itself

Which type of fire alarm system consists of a single control unit that acts as a master alarm system?

Proprietary fire alarm System

Must have the ability to continually monitor itself.

What is the name of the device that is installed inside air ducts, to transport air from the protected area back to the detector element.

Duct Detector

Quack Quack Quack

What is the maximum temperature that a insulation can handle?

90 Degrees Celsius and 194 Degrees Fahrenheit

Ugly's page 73

What are three functions of the fire alarm control unit?

Control the triggering of notification appliances.


Continually monitors a circuit's integrity.


Check the status of initiating device.

What are the three status indications displayed on a fire alarm panel?

Trouble, normal and Alarm

What type of device is disigned to detect abnormally high temperatures?

Heat Detectors

What is Annonciation?

Annonciation is visual and audio alarm (notification)

Spot type heat detector should be located _______?

At least 12 feet from the kitchen to reduce false alarms.

Which type of heat detector concentrates its detecting element in one specific location?

Spot type detector

What is the minimum output level for audible device in a residential dwelling?

85 dB at a distance of 10 feet

What is the maximum output level for audible device?

120 dB

What is the minimum output level for audible devices in a Commercial setting.

75 dB at a distance of 10 feet.

According to NFPA 72 cable assemblies must have a survivability of atleast?

2 hours

Power sources for power-limited fire alarm circuits are limited to a maximum output value of?

30v and 1000VA

SLC is an acronym for _______?

Signaling Line Circuits

What class of fire alarm circuit connects through a two-wire circuit followed by an end-of-line device?

Class B

What is the name of the end of line device on a class B fire alarm system?

Resistor

Chapter 1 in the NEC?

General

Article 100: Definitions

Chapter 2 in the NEC?

Wiring and Protection

Article 200: Use and Identification of Grounded Conductors

Chapter 3 in the NEC?

Wiring Methods and Materials

Article 300: Wiring Methods

Chapter 4 in the NEC?

Equipment for General Use

Article 400: Flexible Cords and Cables

Chapter 5 in the NEC?

Special occupancies.

Article 500: Hazardous (Classified) Location, Class 1, 2, and 3 Divisions 1 and 2

Chapter 6 in the NEC?

Special Equipment

Article 640: Audio Signal Processing, Amplification, and Reproduction Equipment

Chapter 7 in the NEC?

Special Conditions

Article 700: Emergency Systems

Chapter 8 in the NEC?

Communications Systems

Article 800: Communications Circuits

Chapter 9 in the NEC?

Tables

The Ugly's

About how many Articles are there in the NEC?

There are about 140 Articles in the NEC.

What is High cut through resistance?

The ability for a material to withstand mechanical pressure without seperation.

What is CrossTalk?

The unwanted transfer of signals from one conductor to another through the process of electromagnetic induction or capacitive coupling.

What is one solution to crosstalk?

To turn neighboring conductors 90 degrees from each other.

What material should barriers be? (to prevent noise, crosstalk, existing magnetic field, or eddy current)

Steel

What is Skin effect?

Skin effect is the moving of electrons from the inner most part of a conductor to the outer most part, using high frequency.

What is Attenuation?

Signal Loss measured in dB.

NEC Article 760 defines FPLP as ___?

Fire Rated Power-limited Plenum Cable.

What is Abandoned Cable?

It is any class 2, class 3, or communication cable not connected at one end or tagged for future use.

Article 760 defines NPLFP cable as?

Non-Power-limited fire-rated plenum.

What is the formula for the resistance of a conductor?

R=(K*L)/Circular mils

What is Digital Redundacy?

Digital Redundacy is the double copying of information sent to back up first package of information in case of failure of the first.

Digital package checking?

A set of Binary information sent over a communication line, compared to a second set to see if any corruption has occured.