1. Which of the following is not one of the three methods used to size duct systems?

Equal freedom of flow

2. Typical duct velocities for low-velocity duct systems are show in table 5.1. What is the air flow of the main duct return for hotel bedrooms in feet per minute

1300

3. What does a duct configurator do?

Is sizes and analyzes supply duct systems

4. What is meant by equal friction in a duct system?

This method of sizing supply duct systems figures constant pressure loss pre unit length

5. What offsets friction losses in ducts?

Static pressure

6. The Trane Ductulator simplifies the Manual process of sizing ductwork based on the equal-__________methodology.

Friction

7. What are the three primary task for the HVAC system of a building?

To deliver air, to return air, to make up air

8. What is the suggested duct velocity for a high-velocity system used in the main duct supply of a commercial institution

2500-3800

9. Some equipment removes air from a conditioned space and has to be made up. Which of the following is not such a price of equipment?

Microwave oven

10. Proper maintenance of the HVAC system of a building is impossible if proper balance of air _______ is not ensured in all occupied building zones or conditioned spaces.

Flow

11. The HVAC system components in a building require regular ______

Cleaning

12. There are three generally accepted methods of duct cleaning. Which of the following is not one of them?

Wiping with clean rag

13.Pneumatically or______ powered rotary brushes are used to dislodge dirt and dust particles that become airborne; they are then drawn downstream through the duct system.

Electrically

14. What is the factor that must be taken into consideration when planning and operating and HVAC system in elevated areas of the country?

Altitude

15. Conventional vacuuming equipment may ______ extremely fine particulate matter into the building air space rather than collect it.

Discharge

The function is a duct system is to provide a means to transmit air from the air-handling equipment.

True

If the manual method is used to size the duct systems, they should be calculated by following one of the accepted procedures found in standard design handbooks.

True

3. The equal friction method is the most widely used method of sizing lower-pressure, lower-velocity duct systems.

True

4. The static-regain design method sizes the supply-duct system to obtain uniform static pressure at all branches and outlets.

True

5. The trane duct configurator can model both constant and variable volume systems.

True

Cleaning ducts is the job of outside contractors.

False

7. The HVAC system components in a building will require regular cleaning.

True

8. Sanitizing treatments to kill mold, mildew, bacteria, and so forth are generally administering by self-contained foggers or vaporizers or by air-driven spray units.

True

There are three generally accepted methods for duct cleaning

True

In the power-brush method of cleaning a vacuum collection device is connected to the upstream end of the section being cleaned

False

Air washing is another method of cleaning air ducts

True

If you are hiring a contractor for duct cleaning you should ask for proof of insurance and a state license

True

A schedule for inspections of ductwork should be maintained.

True

When designing a ductwork system either manually or by computer the effects of high altitude must be accounted for in the design

True