Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
28 Cards in this Set
- Front
- Back
What does RAST stand for?
|
Recovery
Assist Secure Traverse |
|
What is the purpose of RAST?
|
to help land and secure the helo on the deck.
|
|
TGW?
|
Tail Guide Winch
|
|
How many TGW and where are they located?
|
2. Port and Starboard sides of the flight deck
|
|
Where do TGW secure to
|
to tail end of helo to straighten it before entering the hanger.
|
|
How many AC's do we have on board? Where are they located?
|
4. 1 & 2 in AUX 1 and 3 & 4 in JPe pump room.
|
|
What is the capacity of the ACs?
|
200 ton York Centrifugal
|
|
What is the prime purpose of the AC units?
|
to maintain chill water at 42-48 degrees for cooling equipment.
|
|
What is the secondary purpose of the AC units?
|
Fan coil units for the crew.
|
|
How many reefers do we have onboard? Where are they located?
|
2. AUX 1
|
|
What type of reefers do we have?
|
1.5 ton piston type compressor.
|
|
What is the purpose of the reefers?
|
to remove heat from 2 freeze boxes and one chill box.
|
|
What is the RO unit?
|
Reverse Osmosis.
|
|
How does the RO unit work?
|
Sea water pumped at high pressure through a duplex strainer, 20 micron and 5 micron filters and three membranes.
|
|
Where is the RO unit located?
|
AUX1
|
|
What does the RO unit do?
|
created potable water after it is brominated.
|
|
How many Evaps do we have? Where are they located?
|
2. AUX 1
|
|
What types of evaps do we have?
|
2 stage flash type.
|
|
what do evaps provide?
|
feed water for boilers before bromination. After bromination potable water.
|
|
How mauch water can our evaps produce daily?
|
12,000 gal each
|
|
How many potable water tanks do we have and where are they located?
|
4. 1 & 2 in FWD pump room and 3&4 in shaft alley.
|
|
What is the capacity of the water tanks?
|
1&2 3,000 gal each
3&4 7,0000 gal each |
|
What is potable water brominated to?
|
.2 ppm at sea and 2.0ppm in port if from a non DOD source.
|
|
How many bromination stations do we have?
|
2. 1 in FWD pump room and 1 in shaft alley.
|
|
What are the first 3 stages of distillation?
|
1.) Feed water pump takes suction from sea chest
2.) passes through Helen strainer 3.) picks up heat from 2nd and 1st stage distallate coolers |
|
What are the 2nd 3 steps to distillation?
|
4.) water enters feed heater
5.) water enters 1st and 2nd stage 6.) water is boiled at 165-175 F under a vacuum |
|
What are the 3rd 3 steps to distillation?
|
7.) each stage uses demister pads to separate brine.
8.) brine is pumped over by brine pump 9.) Condensate circulates from boilers to Evaps |
|
What are the last stages of distillation?
|