29 Cards in this Set

  • Front
  • Back

Rainwater leader sizing is based on a rainfall volume in ______ over a period of _________

Millimetres


15 mins

The minimum size of a circular rainwater leader is _____

2”

For conversion of fixture unit loads to litres for sizing purposes , 269 fixture units or less is equal to _________ litres

2360

When the number of fixture units exceeds 260, the load is ______litres for each fixture unit

9.1 litres

A pump rated at 10 imperial gallons per minute would add a load to the drainage system of _____________ litres

681

Basic function of a floor drain

Rapidly removed liquid waste from areas surrounding the drain

List 5 factors for selecting a floor drain

1)max volume of liquid


2)Type of traffic to be expected


3)Types if waste


4)optional accessories


5)Grate appearance

What is the maximum length of a 3” floor drain?

12’

What is the minimum size outlet on a floor drain?

2”

What is the min length of a trap arm for a 3” floor drain?

18” or 450mm

What is the maximum length of a 4” floor drain trap arm at 1/8” per foot?

32’

Can a floor drain be hooked up to a storm drainage system?

Yes

How can a trap seal be maintained in the floor drain?

Trap primer, indirect connection to a drinking fountain, or manually filling

What is the correct term for a rainwater pipe located inside a building ?

Rainwater leader

Briefly explain why rainwater treatment should not be piped to a sewage treatment plant.

Doesn’t require treatment, undo stress in treatment plant

What would happen if rainwater conductor was connected to a septic tank?

Flood the tank rendering it inoperable

Why is a trap necessary between rainwater pipe and sanitary drain?

Keep sewer gases from entering rainwater pipe and exiting at roof level.

State 2 reasons why fixtures should not be connected to rainwater leaders:

-sewage discharged through rainwater into storm is not treated.


-Water is liable to enter through fixtures , flooding the space

Where a rainwater leader connects to a roof hopper, the piping immediately under the hopper should be _______ or provided with an ____________ to prevent __________________.

Offset


Expansion joint


Rupture if the piping joint due to the expansion and contraction caused by temperature changes.

A soil or waste pipe that serves more than one clothes washer and in which pressure zones are created shall not serve for ________________________.

Connecting other soil and waste pipes .

For the purposes of expansion, what is the maximum distance a from the roof may a leader fall before it turns 90• for a horizontal offset.

Must not exceed 5 feet.

What is the minimum length of a horizontal offset of a rainwater leader?

5 feet

If you are installing an expansion joint on a rainwater leader, where must it be located ?

Within 5 feet of the roof.

How do you convert FU’s to Litres?

# FU X 9.1= L

What is the formula if there is less than 260 FU?

No formula. The pipe is sized using a set number of 2360 litres.

Local rainfall intensity in Edmonton per 15 mins?

22mm

Formula for sizing rainwater leaders :


( based on roof measurements )

Length x Width x 22mm rainfall intensity = #Litres

Minimum size for a circular rainwater leader is:

2”