16 Cards in this Set
- Front
- Back
How do you achieve 100% oxygen flow on the oxygen mask |
Red toggle switch pressed to 100% position |
|
What position must the emergency control selector be in for normal oxygen use? |
Fully counter clockwise |
|
How do you test the oxygen mask? |
Press the emergency knob |
|
How do you activate the emergency position of the oxygen mask? |
Rotate emergency knob clockwise approx 90 degrees |
|
How do you use the inbuilt oxygen mask mic? |
Select MASK on BOOM/MASK selector on side console |
|
Where is the oxygen flow indicator located? |
In the mask supply line |
|
What pressure are crew oxygen bottles charged to? |
1800psi |
|
What is the minimum charge required for a crew oxygen bottle to be dispatched? |
1350psi |
|
What is the capacity of crew oxygen bottles? |
310 litres |
|
What is the charge and capacity of passenger therapeutic oxygen bottles? |
1800psi, 120 litres |
|
How many outlets are there on oxygen Bottles? |
Two |
|
What is the fixed pax oxygen system charged to and at what capacity? |
1800psi, 1400 litres |
|
What is the fixed passenger oxygen output pressure regulated to? |
72.5psi |
|
Where is the fixed oxygen bottle charging panel located? |
Rear fuselage equipment bay, behind the rear bulkhead |
|
At what cabin alt will the ADBs deploy? |
11,500ft |
|
Will ADBs deploy when first aid is selected when cabin alt exceeds 11,500ft? |
Yes, first aid just manually activates the 4 therapeutic oxygen points |