1 in 2 lots/units
|
Min parking slot for units with gfa of 50 sqm (R4) 1 in 2 units or more than two but not less than 4
|
|
1 loading slot
|
Min parking slot for articualted vehicle or truck 4.00 x 12.00 m 1 loading slot for standard truck for every 5000 sqm gfa, provide truck maneuvering area outside of RROW (within property lot lines)
|
|
1 per 10 classrooms
|
Min parking slot for Public schools plus 1 off RROW passenger loading space that can accommodate 2 queued PUJ slots
|
|
1 per 100 sqm
|
Min parking slot for every 100 sqm for shopping center and supermarkets
|
|
1 per 100 sqm gfa
|
Min car slot for clubhouses and beach houses and the like
|
|
1 per 100 workers
|
Min bus slot Argriculture related uses + 1 off RROW loading space for 2 queued PUJ's 200 workers or more + 1 loading slot for truck 12.00 x 6 m, 1 loading slot for standard truck evey 5000 sqm
|
|
1 per 100 workers
|
Min Bus slot for Aircraft hangars, open parking carports and garages etc, + 1 off RROW loading space for 2 queued PUJ slots if more than 200 workers
|
|
1 per 100 workers
|
Min Bus slot for Industrial, mills breweries etc, + 1 off RROW loading space for 2 queued PUJ slots if more than 200 workers + 1 loading slot for truck 12.00 x 6.00 m + 1 loading slot for standard truck per 5000 sqm o GFA
|
|
1 per 1000 sqm
|
Min car slot for Aircraft hangars, open parking carports and garages etc,
|
|
1 per 1000 sqm
|
Min car slot for Industrial, mills, breweries etc
|
|
1 per 1000 sqm
|
Min terminal to accommodate at 2 PUJ's/6 trycyles wet and dry public markets
|
|
1 per 1000 sqm gfa
|
Min car slot Agriculture related uses
|
|
1 per 12 beds
|
Min parking slot for nusing homes and orphanages + 1 off-RROW passenger loading space for 2 queued PUJ's.
|
|
1 per 12 beds
|
Min parking slot for Private Hospital + 1 off-RROW passenger loading space for 2 queued PUJ's. + 1 loading slot for trucks 12.00 x 6.00 m +1 loading slot for standard truck for a standard truck per 5000 sqm
|
|
1 per 150 sqm
|
Min parking slot for customer PUJ wet and dry public markets
|
|
1 per 2 units
|
Min parking slot for 18.00 to 40.00 sqm gfa. Office commercial or mixed use condominium
|
|
1 per 20 beds
|
Min car slot for pension/boarding/lodging houses
|
|
1 per 20 sqm
|
Min parking slot for customer per customer area night clubs + 2 tourist parking slot for toursit bus for theater restaurant,
|
|
1 per 25 beds
|
Min parking slot for Mental institutions + 1 off-RROW passenger loading space for 2 queued PUJ's.
|
|
1 per 25 beds
|
Min parking slot for Public Hospital + 1 off-RROW passenger loading space for 2 queued PUJ's. + 1 loading slot for trucks 12.00 x 6.00 m +1 loading slot for standard truck for a standard truck per 5000 sqm
|
|
1 per 3 classrooms
|
Min parking slots for Private Colleges + 1 off RROW passenger loading space that can accommodate 2 queued PUJ slots + 1 school bus slot for every 100 students
|
|
1 per 3 rooms
|
Min parking slot for highly urbanized areas (Hotels)
|
|
1 per 30 sqm
|
Min parking slot for Restaurants, fast-food centers, bars and beerhouses
|
|
1 per 300 sqm
|
Min parking slot for vendor PUJ wet and dry public markets
|
|
1 per 4 alleys
|
Min car slot for Bowling alleys
|
|
1 per 4 lots/units
|
Min parking slot for lots measuring 50 - 96 sqm or gfa of 30 - 42 sqm for (R1/R2/R3 structures)
|
|
1 per 4 units
|
Min parking slot for units with gfa of above 50 - 100 sqm (R5) another slot for units more than 4 but less than 6
|
|
1 per 5 classrooms
|
Min parking slots for Private schools + 1 off RROW passenger loading space that can accommodate 2 queued PUJ slots + 1 school bus slot for every 100 students
|
|
1 per 5 classrooms
|
Min parking slots for Public Colleges + 1 off RROW passenger loading space that can accommodate 2 queued PUJ slots + 1 school bus slot for every 200 students
|
|
1 per 5 units
|
Min car slot for Residential hotels and apartels
|
|
1 per 50 sqm
|
Min car slot for covered amusement parks
|
|
1 per 50 sqm
|
Min parking slot for public recreational ass. Bldg cinemas + 1 bus parking for every 200 spectators
|
|
1 per 50 sqm
|
Min car and PUJ slot + 1 PUB for every 200 sectators for Public assembly buildings
|
|
1 per 5000 sqm
|
Min parking slot for UTS +2 off-RROW passenger loading space for 2 queued PUJ's or PUB's, space to maneuvering outside RROW
|
|
1 per 6 lot/units
|
Min parking slot for lots measuring 32 - 72 sqm or gfa of 18 - 22 sqm for (R1/R2/R3 structures)
|
|
1 per 6 units
|
Min parking slot for units with gfa of 50 sqm (R5) another slot for units more than 6 but less than 12
|
|
1 per 60 rooms/units
|
Min bus parking slot for Residential hotels and apartels
|
|
1 per 7 room
|
Min parking slot for less urbanized areas (Hotels)
|
|
1 per 8 units
|
Min parking slot for units with gfa of 18 - 22 sqm (R5) another slot for units more than 8 but less than 16
|
|
1 per compartment
|
Min car slot for columbarium
|
|
1 per lot
|
Min parking slot for lots measuring 100 - 120 sqm or gfa of 30 - 42 sqm for (R1/R2/R3 structures)
|
|
1 per lot
|
Min parking slot for lots more than 120 sqm or gfa of more than 42 sqm for (R1/R2/R3 structures)
|
|
1 per unit
|
Min car slot for Motels
|
|
1 per unit
|
Min parking slot for 41.00 to 70.00 sqm gfa. Office commercial or mixed use condominium
|
|
1 per unit
|
Min parking slot for more than 70.00 sqm gfa. Office commercial or mixed use condominium
|
|
1 per unit
|
Min parking slot for units with gfa of 50 - 150 sqm (R4)
|
|
1 per unit
|
Min parking slot for units with gfa of above 100 sqm (R5)
|
|
1 Side Abutment
|
Abutments for R2 lot type. No FW/abutments on front or rear property lines
|
|
1 Side Abutment
|
Abutments on all classes of Cultural uses
|
|
1 sq. m
|
Min area of a vent shaft
|
|
1.00 sqm
|
Min window opening area.
|
|
1.20 Sqm / 900 mm width
|
Bath and Toilet
|
|
1/10 -
|
"Whenever the slope of the street is one in ten ( 1/1 0) the sidewalk shall be maintained level for every 20 to 40 meters of run."
|
|
1/10 -
|
"When the grade of two connecting sidewalks are between one in ten { 1/1 0) and one in eight ( 1/8), the two sidewalks shall be joined by means oi a ramp having any convenient slope not exceeding_ one in ten ( 1/1 0)."
|
|
1/2/3/4 hour Fire resistive Occupancy
|
Types of Occupancy Separation
|
|
1/20 area
|
Min window area ratio for toilet, bath rooms, laundry rooms an similar rooms
|
|
1/3 of the sidewalk
|
Max width of planting strip
|
|
1/50 slope
|
Slope of the sidewalk from the bldg. line and should level to the curb.
|
|
1/6 -
|
Sidewalks shall be of uniform width throughout the entire length of the street. The width of a sidewall< shall not be less than 1/6 of the road right-of-way.
|
|
1/6 -
|
Sidewalks of different levels shall be joined by means of a ramp having a convenient slope not exceeding one in six {1/61
|
|
1/8 slope of a driveway
|
Max slope of a driveway if the curb is more than 200 mm in height, must be constructed across the entire width of the sidewalk.
|
|
1:12 gradient
|
Max Gradient of curb cut out
|
|
10 mm
|
Thickness of glass for 2.25 x 2.25 m ad belo2
|
|
10 percent
|
Min Flr. Area for windows w/o artificial ventilation, shall open directly to a court, yard, public st. or alley, or open water courses.
|
|
100 mm
|
Max Rise of entrance and exit steps (not stairs).
|
|
100 mm
|
Min. Rise of a step
|
|
1000 m on each side / 4000 m
|
Min width of a sidewalk and Roadway if RROW is 6.00 m.
|
|
1000 m on each side / 5000 m
|
Min width of a sidewalk and Roadway if RROW is 7.00 m.
|
|
1000 m on each side / 6000 m
|
Min width of a sidewalk and Roadway if RROW is 8.00 m.
|
|
1000 m on each side / 6700 m
|
Min width of a sidewalk and Roadway if RROW is 8.70 m.
|
|
1000 mm
|
Min width of an Aisle serving both sides
|
|
11/12 -
|
"Whenever the slope of the street does not exceed one in twelve t 111 2) the sidewalk grade shall follow the level or slope of the street."
|
|
1100 mm
|
Min width of Side Aisles
|
|
1100 mm
|
Min. Width of a stairway serving an occupant load of more than 50
|
|
1100 mm
|
Min. Width of every corridor or exit balcony
|
|
12 mm
|
Thickness of glass for 3.00 x 3.00 and below
|
|
12.00 Cum
|
Workshops, Factories and Offices Air Space / person
|
|
1200 mm
|
Max Door Leaf Width
|
|
1200 mm
|
Max height of flush control (Toilet flush)
|
|
1200 mm
|
Max. Landings from the direction of travel. Typically of same width as the stairs. Shall not be reduced in width by more than 100 mm by a door when fully opened.
|
|
1200 mm
|
Min clear width of a walkway between the front ends of parked cars
|
|
1200 mm
|
Min. width of a temporary walkway
|
|
1200 mm on each side
|
Min width of sidewalk if RROW is 9.00 m or more
|
|
1200 mm width
|
Min required clear level space on the corridor side of the door
|
|
14 seats
|
Max distance between Aisles
|
|
14 storeys
|
Min width of a court > 14 storeys shall be computed on the basis of fourteen storeys.
|
|
14.00 Cum
|
Habitable Room Air Space / Person
|
|
15 mm
|
Thickness of glass over 3.00 x 3.00
|
|
15 seats
|
Max number of seats between any seat and an Aisle for open air stands w/o backrest
|
|
150 mm
|
Min. Run for Winding Stairways
|
|
1500 mm
|
Min width of a court in cluster living units.. Ex, quadruplex, rowhouses etc..
|
|
1500 mm x 1500 mm
|
Clear unbostructed space for public telephones
|
|
1800 mm
|
Mezanine Clear Ceiling Height above and below
|
|
1800 x 1500 mm
|
Min area required for entrances with vestibules provided at level area
|
|
2 1/2 Flrs or 7.5
|
Max BHL if 1 RROW services a lot and only 4.00 to 5.00 m wide
|
|
2 Exits Min.
|
Floors above the first storey having an occupant load of more than 10
|
|
2 Exits Min.
|
Floors above the second storey, basements and cellars used for other than service of the building shall have not less than two exits.
|
|
2 Flrs or 6 m
|
Max BHL if 1 RROW services a lot and only 3.00 m wide or less
|
|
2 per unit
|
Min parking slot for units with gfa of 150 sqm (R4)
|
|
2 Sides only
|
Abutments for R4 lot type. No FW/abutments on front or rear property lines
|
|
2 Sides or 1 Side and rear
|
Abutments for C3 lot type. No abutments on front property lines
|
|
2 Sides or 1 Side and rear
|
Abutments for R3 lot type. No FW/abutments on front property lines
|
|
2 Sides or 1 Side and rear
|
Abutments for R5 lot type. No FW/ abutments on front property lines
|
|
2 Sides or 1 Side and rear
|
Abutments on all classes of UTS
|
|
2 slots
|
Min car and jeepney/shuttle slot per 50 sqm for Churches
|
|
2 Stairways
|
Each mezzanine floor used for other than storage purposes, if greater in area than 185 square meters or more than 18.00 meters in .,Y dimension, shalt have at least two stairways to an adjacent floo
|
|
2 steps
|
Min number of steps for entrance and exits
|
|
2 tourist bus
|
Min parking slot for tourist buses in each Hotel
|
|
20 mm
|
Min diameter of buttons at elevator control panels and 1 mm max depression depth
|
|
20 percent
|
Multi Flr. Parking garages w/in 200 m radius of bldg. provide at least 80% of parking are integrated in the building design
|
|
200 mm
|
Max. Rise of a step
|
|
200 mm
|
Min planting strip for shrubs on both sides of RROW
|
|
200 x 600 mm
|
For Exterior Use
|
|
2000 mm
|
Min width of a court for 1 or 2 storey bldg.
|
|
2000 mm
|
Min. Height of an Exit Door
|
|
2000 mm
|
Min. Overhead clearance of stairways
|
|
2100 mm
|
Minimum Ceiling Height of succeding Storey above the finished floor.
|
|
2150 x 6000 mm
|
Average automobile parking slot for parallel parking
|
|
240 sq. mm
|
Min window are of opening for toilet bath rooms, laundry rooms and the like
|
|
2400 mm
|
Doors, Windows and like above the or groundline shall not project beyond the property line when fully opened or upon opening except for fire exit doors.
|
|
2400 mm
|
Min. Height of Fence
|
|
2400 mm
|
The vertical clearance between the undermost surface of lh! awning and the pavement or ground line
|
|
2400 mm
|
Min.of Canopies above the railway
|
|
2400 mm
|
Minimum Ceiling Height of 2nd Storey
|
|
2400 mm
|
Minimum Ceiling Height with Artificial Ventilation
|
|
250 mm
|
Min. Run for Circualr Stairways
|
|
250 mm
|
Min. Run of a step
|
|
250 sqm
|
Max Area of combustible Attic
|
|
2500 x 5000 mm
|
Average automobile parking slot for perpendicular or diagonal parking
|
|
2700 mm
|
Minimum Ceiling Height of 1st Flr.for multiple storeys
|
|
2700 mm
|
Minimum Ceiling Height with Natural Ventilation
|
|
2700 mm ceiling height
|
Required windows may open into a roofed porch where the porch:
|
|
280 mm
|
Min. Stairway thread
|
|
3 Exits Min.
|
Occuapant load of 500 to 999
|
|
3 Flrs or 9 m
|
Max BHL if 1 RROW services a lot and only 6.00 to 7.00 m wide
|
|
3.00 Cum / 1.00 Sqm
|
Shool Room Air Space / 1 sqm of floor are per person
|
|
3.00 Sqm / 1500 mm width
|
Kitchen
|
|
300 mm
|
Min diemension of an Air duct
|
|
300 mm
|
Min haight of an air duct above the street surface
|
|
300 mm
|
Min threads for entrance and exits.
|
|
300 mm
|
Min. Run from the side of the stairway where the treads are narrower for Winding stairways
|
|
300 mm
|
The horizontal clearance between the awning and the curb line shall not be less than 300 millimeters.
|
|
300 mm
|
The horizontal clearance between the outermost edge of the marquee and the curb line
|
|
300 mm
|
Increase in rear and side court witdh for each add. Storey for bldgs. > 2 storeys in height to 14
|
|
300 mm
|
Min planting strip for trees on both sides of RROW
|
|
300 mm
|
Min space between the back of each seat and the front of the seat immediately behind it
|
|
300 mm
|
Min width of tactile strips shall be installed before hazardous areas for stairs, also on the top and bottom
|
|
300 sq. mm
|
Min area of an Air duct
|
|
3000 mm
|
Min. Arcade height above the established sidewalk grade
|
|
3000 mm
|
Min. Vertical Clearance of an Arcade
|
|
3000 mm
|
Min. Width of access road for Interior or rear lots
|
|
3000 mm
|
Min. Width of access road for Interior or rear lots 6 units
|
|
3000 mm
|
The vertical clearance between the pavement qr ground line and the undersurface of any part the marquee
|
|
3000 x 9000 mm
|
Minimum parking/unloading/loading slot for jeepneys
|
|
3600 mm
|
Max. Vertical distance bet. landings
|
|
3600 x 12000 mm
|
Min truck or bus parking slot
|
|
3600 x 18000 mm
|
Min parking slot for articulated truck (sufficient to accommodate a 12.00 m container van or bulk carrier)
|
|
38 mm
|
Max. Width of the nosing from the run
|
|
4 Exits Min.
|
Occupant load of 1000 or more
|
|
4 kg
|
Max operable pressure or force of doors, 1 kg for interior doors
|
|
4 PUJ's or 3 PUB's
|
Transit stations queued slots UTS
|
|
400 mm
|
Max rise of one row of seats to the next
|
|
4000 mm
|
Min. Width of access road for Interior or rear lots 7 to 15 units
|
|
45.00 m
|
Distance to Exit w/o a Sprinkler System
|
|
45.00 m
|
Max distance of an Aisle from an exit door
|
|
450 mm
|
Clear width of rows of 18 seats or less
|
|
450 mm
|
Min width of seats
|
|
480 mm
|
Max widt of seats
|
|
480 mm
|
Max height of urinals from the floor to the nose
|
|
500 mm
|
"Arcade shall be cantilevered from the building line over the sidewalk, and the horizontal clearance between the curb line and the outermost face of any part of the arcade shall not be less than 500 millimeters."
|
|
500 mm
|
Clear width of rows of 35 seats or less
|
|
5000 mm
|
Min. Width of access road for Interior or rear lots 16 to 25
|
|
525 mm
|
Clear width of rows of 45 seats or less
|
|
550 mm
|
Clear width of rows of 46 seats or more
|
|
6 seats
|
Max number of seats between any seat and an Aisle for open air stands w/ backrest
|
|
6.00 Sqm / 2000 mm width
|
Rooms for Human Habitation
|
|
60 deg
|
Risers should be sloped or the undersides of the nosings should have a 60 degree angle minimum from the horizontal
|
|
60 m
|
Distance to Exit w/ a Sprinkler System
|
|
600 mm
|
Min diemnsion of a vent shaft
|
|
600 mm
|
Min space of rows from back to back w/o backrest
|
|
600 mm on each side / 3.00 m
|
Min width of a sidewalk and Roadway if RROW is 4.20 m.
|
|
6000 mm
|
Max. Vertical Clearance of an Arcade
|
|
6000 mm
|
Min. Width of access road for Interior or rear lots 26 to 35
|
|
650 Kg/Sqm
|
Live load capacity of a temporary walkway
|
|
7 seats
|
Max distance of a wall to an Aisle
|
|
700 mm
|
Min. clear width of an exit way
|
|
750 mm
|
Min space of rows from back to back w/ backrest
|
|
750 mm
|
Min. length of Eaves, canopies, awnings over required windows from side and rear prop. Line
|
|
750 mm
|
Min. Width of a private stairway w/ an occupant load of less than 10
|
|
750 sqm
|
Max Area of non-Combustible material or equipped with approved automatic fire extingguishing systems
|
|
7500 m
|
Min. Width of access road for Interior or rear lots > 35 units
|
|
8 mm
|
Thickness of glass for 1.10 x 1.10 m and below
|
|
800 mm
|
Min clear width of a telephone booth opening
|
|
800 mm
|
Min width of an Aisle
|
|
800 mm
|
Planting Strip for Sidewalks 2.00 m or more on its outer side
|
|
800 mm / 900 mm
|
Above the leading edge of the stair thread or nosing.
|
|
800 mm on each side
|
Min with of a planting strip if the sidewalk is 2.00 and more and should separate the curb line from the sidewalk.
|
|
820 mm
|
Max height of the window opening from the floor
|
|
820 mm x 1000 mm
|
Min clear opening of a window
|
|
840 mm
|
Min spacing of rows of seats back to back.
|
|
850 mm
|
Min space of rows from back to back for chairs
|
|
90 percent
|
Percentage of occupancy for coner lot
|
|
900 mm
|
Min. Width of a stairway serving an occupant load of 50 or less
|
|
900 mm
|
Min. Width of an Exit Door
|
|
A Carport
|
Not part of TOSL if roofed or roofed with overhangs and must by counted as part of AMBF
|
|
A Front Yard
|
May serve as a carport for B R2 or B R3 or R4 for single family dwelling units only
|
|
abuts a court, yard, public st. or aley or pen water course.
|
Required windows may open into a roofed porch where the porch:
|
|
All sides
|
Abutmens on all classes of Institutional uses
|
|
AMBF = TLA - Land Area Required for Courtyards + Additional Buildable Lot area due to firewall construction if permitted
|
Allowable Maximum BLDG Footprint
|
|
AMVB
|
Allowable Maximum Volume of a Building
|
|
Arcades
|
"All arcades shall be of uniform width throughout the entire length of the street within the block. or from one street corner to another."
|
|
Awning
|
is a movable shelter supported entirely from an exterior wall of a building and of a type which can be retracted, folded, or collapsed against the face of a supporting building.
|
|
B R3 abutment on 2 sides and rear
|
May be allowed if opne space, window opening, and firewall with a min of 2 hour fire resist rating and height of 400 mm abve the line roof.
|
|
Basic R2
|
"Single-attached or duplex building/ structure of from one {1} storey up to three (3) storeys in height and with each unit for separate use as single-family dwellings."
|
|
Basic R3
|
"Row house building/structure of from one (1) storey up to three (3) storeys in height and with each unit for separate use as single-family dwellings; and"
|
|
BHL
|
Building Height Limit
|
|
Exterior doors/windows All Types
|
1 hour
|
|
FLAR
|
Floor to Lot Area Ratio
|
|
From 1/4 up to 1/3 of RROW Width / 200 mm each side
|
10.00 - 19.00 meters Range of required Sidewalk and Planting strip widths total at both sides of RROW
|
|
From 1/4 up to 1/3 of RROW Width / Optional
|
Below 10.00 meters Range of required Sidewalk and Planting strip widths total at both sides of RROW
|
|
From 1/6 up to 1/3 of RROW Width / 300 mm each side
|
20.00-24.00 meters Range of required Sidewalk and Planting strip widths total at both sides of RROW
|
|
From 1/6 up to 1/3 of RROW Width / 300 mm each side
|
25.00- 29.00 meters Range of required Sidewalk and Planting strip widths total at both sides of RROW
|
|
From 1/6 up to 1/4 of RROW Width / 600 mm each side
|
30.00 meters & above Range of required Sidewalk and Planting strip widths total at both sides of RROW
|
|
GFA = TLA * Recommended Flr. To Lot Area Ratio (FLAR)
|
Gross Floor Area in SQM
|
|
has 1 longer side at least 65% open and unbostructed
|
Required windows may open into a roofed porch where the porch:
|
|
High Rise
|
16 Storeys or taller in height, 40 meters above grade, mandatory elevators, fire escapes and sprinkler systems, arresters, beacons and other safety systems
|
|
International Symbol
|
A / B / C / D / E / F for disabled
|
|
ISA = TOSL - USA
|
Minimum Unpaved Surface Area
|
|
Low Rise
|
1 to 5 Storeys in height. 3 to 15 meters above grade, mandatory fire escapes and other safety systems
|
|
MACA = PSO + ISA
|
Maximum Allowable Construction Area
|
|
Max R2
|
"Low-rise multi-level building/ structure of from three (3) up to five (5) storeys in height and for use as multiple family dwellings."
|
|
Max R3
|
"Medium-rise multi-level building/structure of from six (6) up to twelve (12) storeys in height and for use as multiple family dwellings"
|
|
Medium Rise
|
6 to 15 Sotreys in height, 18 to 45 m above greade, mandatory fire escapes and sprinkler systems
|
|
NFA
|
Net Floor Area
|
|
No Abutments
|
Abutments for R1 lot type
|
|
No Openings
|
On/At/Within/through all types of abutments eg. Firewals erected along prop. Line excep for vent wells
|
|
OFB
|
Outermost Faces of Building
|
|
PSO * TLA = TGFA
|
Allowable Maximum Total Gross Floor Area
|
|
PSO = AMBF / TLA
|
Percentage of Site Occupancy
|
|
R1
|
"A low density residential use or occupancy, characterized mainly as a low-rise single--detached building/structure for exclusive use as a single (nuclear) family dwelling. This includes R-1 structures within exclusive subdivisions and relatively exclusive residential communities which are not subdivisions"
|
|
R2
|
"A medium density residential use or occupancy, characterized mainly as a low rise single-attached, duplex or multi-level building/structure for exclusive use as multiple family dwellings. This includes R-2 structures within semi-exclusive subdivisions and semi-exclusive residential communities which are not subdivisions"
|
|
R3
|
"A high density residential use or occupancy, characterized mainly as a tow-rise or medium-rise building/ structure for exclusive use as multiple family dwellings with mixed housing types. R-3 structure may include low-rise or medium-rise residential condominium buildings that are already commercial in nature and scale.
|
|
R4
|
"A medium to high density residential use. or occupancy, characterized mainly as a low-rise townhouse building/ structure for exclusive use as multiple family dwellings. The term R-4 specifically refers to the buildinglstructure on an individual lot (a townhouse unit) and generally refers to the series or rows of R-4 buildings/structures within a subdivided lot or property (an R-4 development)."
|
|
R5
|
"A very high density residential use or occupancy, characterized mainly as a medium-rise or high-rise condominium building/structure for exclusive use as multiple family dwellings."
|
|
TGFA = GFA (in sqm) + Non-GFA area - All requirements for courts at all floors (above grade in sqm.)
|
Total Gross Floor Area in Sqm
|
|
TLA = PSO + TOSL
|
Total Lot Area
|
|
TOL/165
|
Width of exit shall be divided approx. equally among separate exits.
|
|
TOSL = ISA + USA
|
Total Open Space within Lot
|
|
Type I
|
Type I buildings shall be of wood construction. The structural elements may be any of the materials permitted by this Code.
|
|
Type I/II
|
Non Fire Restricted Zones
|
|
Type II
|
Type II buildings shall be of wood construction with protective fire-resistant materials and one-hour fire-resistive throughout': Except, that permanent non-bearing partitions may use fire-retardant treated wood within the framing assembly.
|
|
Type II/III , Exterior Bearing and non Bearing walls
|
1 hour fire resistive rating
|
|
Type II/III , Structural frames
|
1 hour fire resistive rating
|
|
Type II/III/IV , 2 hours resistivity
|
Fire Restrictive Zones
|
|
Type II/III/IV , Interior Bearing walls
|
1 hour fire resistive rating
|
|
Type Ill
|
Type Ill buildings shall be of masonry and wood construction. Structural elements may be any of the materials permitted by this Code: Provided, that the building shall be one-hour fire-resistive throughout. Exterior walls shall be of incombustible fire-resistive construction.
|
|
Type IV
|
Type IV buildings shaH be of steel, iron, concrete, or masonry construction. Walls, ceilings, and permanent partitions shall be of incombustible fire· resistive construction: Except, that permanent non-bearing partitions of one-hour fireresistive construction may use tire-retardant treated wood within the framing assembly.
|
|
Type IV, Structural Frames
|
2 hour fire resistive ratings
|
|
Type IV/V , 3 - 4 hours resistivity
|
Highly Fire Restrictive
|
|
Type IV/V , Exterior Bearing and non Bearing walls
|
4 hour hour fire resistive rating
|
|
Type V
|
Type V buildings shall be fire-resistive. The structural elements shall be of steel, iron, concrete, or masonry construction. Walls, ceilings, and permanent partitions shall be of in'combustibte fire-resistive construction.
|
|
Type V , Interior Bearing walls
|
3 hour fire resistive rating
|
|
Type V, Structural Frames
|
3 hour fire resistive rating
|
|
Uncovered Driveways, Access Rd. & Parking spaces
|
May be considerd part of the open space provded that ar open and unobstructed upward like courts and yards.
|
|
USA = TOSL - ISA
|
Maximum Allowable Impervious Surface Area
|
|
Vertical or Horizontal
|
Forms of Occupancy Separation
|