Particularly in the HRM and LRM May be susceptible to EMI from ships and land based RF transmitters and crew. Interference can cause what?

False positives and/or erratic behavior

LRM May break at about?

110 lbs of tension

The last detector must have

An end cap to prevent mech and water damage

Where does the serial number end go?

Towards the top end of the string ( towards the module)

Don’t use with external power supply without power pack + why

This will cause incorrect dose rate values and ID results

The AN/PDX-2 kit is for what

Locate radiological sources and provide field expedient collection and ID of spectra for REACHBACK AND ANALYSIS

In gamma fields higher then 12mR/hr hrm will?

Display “9” in the g window and maximize the duty cycle of the alarm. Update will do nothing

The HRM can be carried under water how deep?

66ft (20.12m)

HRM weight with battery

13 oz

Integration time of HRM aka response time

Less than 1 second

HRM battery time?

1 month continuous

HRM operation temp

5 to 122 degrees Fahrenheit

HRM storage temp

-10 to 122 degrees Fahrenheit

HRM alarm type

Two 7 segment led displays


Duty cycle based audio tone


Duty cycle based vibrator


Real time led blue for neutrons

What type of detector is the HRM gamma ray

Cesium iodide scintilltor

HRM gamma detector size

.5 inches x 1.5 inches

HRM detector sensitivity

Typically 2.2 counts per second per micro Rem per hr

HRM Neutron detector type?

Helium-3.


8.3 atmospheres absolute

HRM neutron detector size

.75 inches x 4.8 inches

HRM neutron detector sensitivity

10.5 cps/nv

After low temp storage (-10 degrees) devices should be warmed at room temp for? And why?

15 minutes prior to turning on because May have unreadable displays and may false alarm

HRM has what switch

3 position rotary switch

For gamma detection When you hit update on the HRM it gathers the last?

6 seconds of data


Neutron detection doesn’t require a background

For gamma detection When you hit update on the HRM it gathers the last?

6 seconds of data


Neutron detection doesn’t require a background

When do you need to update the HRM

When a U is displayed- alarm levels are too low


When HRM alarms moving from high background to low background


When HRM is maxed at 9

When is a U displayed on the HRM

Current radiation level is less than 25% of stored background

What when an H on the HRM?

Help failure during detection

HRM display is rotating counterclockwise? (Hula hoop)

HRM is measuring radiation background during startup

How often does the HRM flash for ok operation

Every 20 seconds

HRM flashing L every 20 seconds

Low battery voltage

HRM neutron displays a 1 is?

6-12 cps

HRM neutron detector displays a 9

>138 cps

Blue led on HRM will flash on average?

Once every minute or 2 can happen several times per minute

When the HRM is powered up what segment lights up?

Middle segment on the gamma detector it indicates a self test

If HRM fails self test?

Middle line will stay solid check battery and replace if necessary

How fast should you sweep with the HRM?

Two feet per second or slower

For most accurate results get within - with HRM

Two feet of every object in the search area

Keep HRM within _ of the surface of item

2-3 inches

HRM has been optimized for

Interdiction and search

Shitty batteries can cause HRM issues why?

Higher internal resistance in some batteries

PDX-2 kits need recalibration every?

24 months

What is the LRM

Self contained gamma ray and thermal neutron radiation detector

LRM has how many detectors

18 gamma and 9 neutron

Rearranging the detectors will degrade the LRM capes in what mode

Linear

LRM weight?

11.70 lbs

LRM cable length?

80ft

LRM batt life?

24 hours without backlight


12 with backlight

LRM op temp?

5-122 degrees Fahrenheit

LRM storage temp

-10-122 degrees Fahrenheit

How’s the LRM with water?

Water resistant

LRM carry bag dimensions?

7 in x 19 inches

LRM gamma integration time?

.5 seconds

LRM neutron response time?

.5 seconds

Left side of LRM has what?

Shows each gamma module

Right side of LRM shows what?

Each neutron module

What does the LRM control module show on linear mode

The status display is 1 second every 20 seconds

What does the LRM display in totalize mode?

Waterfall log of summed gamma (leftside) neutron (rightside)

The LRM has what switch?

5 position switch and can be moved quickly without rebooting

How does the LRM update button work?

Averages the last 16 seconds of data?

Can you add or remove modules while the LRM is on?

Yes

What’s the gamma detector in the LRM

Cesium iodide scintillator

LRM gamma detector sensitivity?

2.2 cps per micro R/hr

LRM gamma detector low energy cutoff

45 kev

LRM gamma detector low energy cutoff

45 kev

LRM neutron detector type

Helium 3 -8.3 atmospheres

LRM gamma detector low energy cutoff

45 kev

LRM neutron detector type

Helium 3 -8.3 atmospheres

LRM neutron detector size

.75 inch


4.8 inches

LRM gamma detector low energy cutoff

45 kev

LRM neutron detector type

Helium 3 -8.3 atmospheres

LRM neutron detector size

.75 inch


4.8 inches

LRM neutron detector sensitivity

10.5 cps/nv

LRM how many feet of cable connect the control module to first detector

9 feet for slack on containers

How much batt is left in LRM after low batt warning?

1 hour

After LRM powers up?

Gamma displays will display clockwise circle for 16 seconds

If the update button is not pressed in 5 seconds LRM?

LRM with auto go into linear mode

In totalized mode the LRM measures in?

Counts per second

To conduct a summed or totalized search with LRM?

Sweep at 2-6 feet per second


Get within 10-15 feet of each object

LRM in totalized mode the plot shows 45 but in lines is 16 seconds used for update see pic

Back (Definition)

Doing container search on LRM you can do what with extra?

Leave in bag or double over on self

How big is the tarp on the LRM

5ft x 4 ft

Finder weight

2.76 lbs w batts

Finder weight

2.76 lbs w batts

Finder op temp?

5 to 131 Fahrenheit

Finder weight

2.76 lbs w batts

Finder op temp?

5 to 131 Fahrenheit

Finder drop test?

2.62 ft on concrete

Finder sensitivity

500 cps per 100mrem/h

Finder dose range

10 micro rem to 100 rem

How long must the power pack +be charged?

At least 12hr before turning on

Power pack + uses what batts

4 AA 1.2v to 1.8v

Finder op time?

Up to 8 hours with NiMH in dose rate mode

What typical values are shown in finder for batteries

5V for fully charged or 6v when power pack + is being charged

What volts will finder shut off?

3.9V

What size screwdriver for opening finder batt pack?

Small #1 flat head screwdriver

What firmware finder needs to be returned

3.18.05

Finder suggested default settings are?

Id 4 isotopes using 300 second acquisition time and 0 seconds extended time

What library is the EOD library

Secur

What happens if backup battery is dead in finder

No spectra will be saved once unit is turned off or batt dies

What does a U indicate on the finder

Successful calibration hasn’t happens yet

At what dose rate will finder go from the scintillation detector to GM tube?

500mrem/hr

Finder is not intended as a

Search tool

When finder mode is selected but gather how much background?

8 seconds

What happened if finder displays “ insufficient counts or low activity”

Time to short or levels too low algorithm wasn’t started

Finder nuclide displays range?

1 unlikely to 10 very likely

How many spectra can be saved

100 total 0-99

Udr15 is

Portable radiation detector detecting neutron/gamma radiation dose and gamma dose rate

Udr15 measuring and display range

0-500 r/hr gamma dose rate


Doseimeter can measure and store doses up to 999 R

Udr15 batts?

4 aaa dry cells

Udr15 batt life

100 hr normal op


Sleep mode 1000 hrs

Udr15 op/storage temp

-51 to 120 Fahrenheit


Storage -60 to 160 Fahrenheit

Udr15 op/storage temp

-51 to 120 Fahrenheit


Storage -60 to 160 Fahrenheit

Udr15 altitude op?

15,000 ft above sea level

Udr15 humidity capes

95%

Water resistant udr15

Up to 3 feet deep

Udr accuracy

+\- 20% of true dose

Udr will display what In most background areas?

.020

Udr units will blink every ? To indicate its working?

2 seconds

If udr is flashing a what the dosimeter should be replaced soon

A flashing 4

Most udr things are what seconds?

10 seconds

Udr when pressing the light button it lights up for?

Approx 6 second or 5? Challenge this question

When udr has 600 minutes left?

Blinking BAT will appear at top left corner

When replacing udr batts hold in what hand?

Left