Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
164 Cards in this Set
- Front
- Back
WHERE IS FWD MAIN MACHINERY ROOM LOCATED?
|
6-65-0-E
|
|
WHERE IS AFT MAIN MACHINERY ROOM LOCATED?
|
6-81-0-E
|
|
WHERE IS AUX MACHINERY ROOM LOCATED?
|
6-73-0-E
|
|
WHERE IS FWD EMERGENCY DIESEL GENERATOR ROOM LOCATED?
|
4-41-2-E
TWO DECKS UNDER CPO BERTHING PORT SIDE FWD AC MACHINERY ROOM |
|
WHERE IS AFT EMERGENCY DIESEL GENERATOR ROOM LOCATED?
|
2-114-2-E
AFT CHT PUMP ROOM |
|
HOW MANY PHASES ARE IN THE BASIC STEAM CYCLE?
|
4
|
|
WHAT ARE THE 4 PHASES OF THE BASIC STEAM CYCLE?
|
FEED PHASE
GENERATION PHASE EXPANSION PHASE CONDENSATION PHASE |
|
WHAT MAJOR EQUIPMENT ARE IN THE FEED PHASE?
|
DFT, MAIN FEED BOOSTER PUMP, MAIN FEED PUMP, FEED WATER CONTROL VALVE
|
|
WHAT MAJOR EQUIPMENT ARE IN THE GENERATION PHASE?
|
BOILER & ECONOMIZER
|
|
WHAT MAJOR EQUIPMENT ARE IN THE EXPANSION PHASE?
|
MAIN ENGINE, SHIP SERVICE TURBINE GENERATOR (SSTG), REDUCTION GEARS (M/ENG & SSTG'S)
|
|
WHAT MAJOR EQUIPMENT ARE IN THE CONDESATE PHASE?
|
MAIN CONDENSER/HOTWELL, AUX CONDENSER/HOTWELL,MAIN CONDENSATE PUMP, AUX CONDENSATE PUMP, MAIN CIRC PUMP, AUX CIRC PUMP, MAIN AIR EJECTOR CONDENSER, AUX AIR EJECTOR CONDENSER, FIRST STAGE FEED HEATER
|
|
WHAT TYPES OF BOILERS DOES THE BOXER HAVE?
|
V2M D-TYPE BOILER
D-TYPE (TUBE BUNDLE SHAPE) 700 PSI |
|
WHAT IS THE OPERATING PRESSURE AND TEMP FOR MAIN STEAM SYSTEM?
|
700 PSI @ 900 DEGREES F
|
|
NAME THE MAJOR PARTS OF THE BOILER:
|
ECONOMIZER, STEAM DRUM, GENERATION TUBES, SUPER HEATER, DE-SUPER HEATER (WATER DRUM), FURNACE, FORCE DRAFT BLOWERS (FDB), PORT USE FAN (PUF)
|
|
WHERE IS #2 BOILER LOCATED?
|
FWD MMR
|
|
WHERE IS #1 BOILER LOCATED?
|
AFT MMR
|
|
HOW MANY GALLONS OF FEED WATER DOES THE DFT HOLD?
|
3500 GALLONS
|
|
WHAT IS THE FUNCTION OF THE DFT?
|
TURNS CONDENSATE INTO FEED WATER, DE-AERATES CONDENSATE, PRE-HEATS CONDENSATE TO 250*F, FEED WATER RESEVOIR
|
|
HOW MANY MAIN FEED PUMPS DOES THE BOXER HAVE?
|
4
|
|
HOW MANY FUEL OIL SERVICE PUMPS DOES THE BOXER HAVE?
|
4
|
|
WHAT ARE THE BOILERS USED FOR?
|
TO PRODUCE MAIN AND AUX STEAM FOR SHIPS PROPULSION, ELECTRICAL POWER, & WATER PRODUCTION
|
|
WHERE IS 1A FORCED DRAFT BOILER LOCATED?
|
AFT MMR
|
|
WHAT IS THE FUNCTION OF THE MAIN FEED BOOSTER PUMP?
|
MOVES FEED WATER FROM DFT TO MAIN FEED PUMP(MFP)
|
|
HOW MANY LUBE OIL PUMPS (MAIN ENGINE/REDUCTION GEAR) ARE ON THE BOXER?
|
6
|
|
WHAT IS THE FUNCTION OF THE FEED WATER CONTROL VALVE (FWCV)?
|
CONTROLS AMOUNT OF FEED WATER TO ENTER BOILER
|
|
THE 3 ELEMENTS OF THE AUTO BOILER CONTROL SYS (ABC)?
|
FEED WATER CONTROL, FUEL OIL CONTROL, COMBUSTION AIR CONTROL
|
|
WHAT IS THE PURPOSE OF THE CHELANT SYS?
|
TO TREAT BOILER WATER TO PREVENT SCALE FORMATION INSIDE BOILER TUBES & TO MINIMIZE CORROSION THAT WILL DAMAGE BOILER TUBES.
|
|
WHAT ARE THE 2 MAJOR COMPONENTS OF THE MAIN ENGINE?
|
HIGH PRESSURE TURBINE LOW PRESSURE TURBINE
|
|
WHAT IS THE PURPOSE OFTHE MAIN REDUCTION GEAR?
|
REDUCE SHAFT SPEED TO PROPELLER SPEED
|
|
WHAT IS THE MAX SHAFT HORSE POWER (AHEAD DIRECTION)?
|
35,000 SHP
|
|
WHAT ARE THE 4 MAIN BEARINGS USED FOR PROPULSION?
|
MAIN THRUST
LINE SHAFT STERN TUBE STRUT |
|
HOW MANY LINE SHAFT BEARINGS ARE ON THE STARBOARD SHAFT?
|
5
|
|
HOW MANY LINE SHAFT BEARINGS ARE ON THE PORT SHAFT?
|
8
|
|
WHAT MAIN ENGINE IS THE PORT SHAFT CONNECTED TO?
|
FWD ENGINE
#2 MAIN ENGINE |
|
WHAT ARE THE 4 MAIN BEARINGS USED FOR PROPULSION?
|
MAIN THRUST
LINE SHAFT STERN TUBE STRUT |
|
HOW MANY LINE SHAFT BEARINGS ARE ON THE STARBOARD SHAFT?
|
5
|
|
HOW MANY LINE SHAFT BEARINGS ARE ON THE PORT SHAFT?
|
8
|
|
WHAT MAIN ENGINE IS THE PORT SHAFT CONNECTED TO?
|
FWD ENGINE
#2 MAIN ENGINE |
|
WHAT TYPE OF PROPELLERS IS ON THE BOXER?
|
6 BLADE, BRONZE ALLOY, 16.5 FT DIA, 30,000 LBS
|
|
WHAT IS THE FUNCTION OF THE MAIN CONDENSER?
|
CONDENSES STEAM FROM LP TURBINE INTO WATER (CONDENSATE) USING SEA WATER
|
|
WHAT DOES THE MAIN ENGINE AHEAD THROTTLE VALVE CONTROL?
|
MAIN STEAM FLOW INTO AHEAD TURBINE ELEMENTS OF THE HP & LP TURBINES
|
|
WHAT DOES THE MAIN ENGINE ASTERN THROTTLE VALVE CONTROL?
|
MAIN STEAM FLOW INTO THE ASTERN LP TURBINE ELEMENT
|
|
WHERE IS THE AHEAD & ASTERN THROTTLE VALVES LOCATED?
|
IN FWD & AFT ENCLOSED OPERATING STATIONS (EOS)
|
|
WHERE IS MAIN CONTROL?
|
FWD MMR
6-65-0-E |
|
WHAT IS THE RESPONSIBILITY OF THE ENGINEERING OFFICER OF THE WATCH (EOOW)?
|
RESPONSIBLE FOR THE PROPER OPERATION OF ENG PLANT AND SAFTETY WHILE UNDERWAY, & AUX STEAMING. IN CHARGE OF MAIN PROP PLANT & ASSOCIATED AUX.
|
|
WHO DOES EOOW REPORT TO?
|
OOD
|
|
WHAT IS THE RESPONSIBILITY OF THE ENGINEERING DUTY OFFICER (EDO)?
|
ENG DUTY DEPT HEAD WHILE IN PORT, IN PORT FIRE PARTY, ENG SPACES & WATCHES, ADMIN WHILE AUX STEAMING
|
|
DAMAGE CONTROL WATCH SUPERVISOR (DCWS) IS RESPONSIBLE FOR?
|
MONITOR FIRE AND FLOODING ALARMS, MONITORS FIRE FIGHTING & BALLASTING SYS, MONITORS S/S & AUX ROVER.
|
|
WHERE DOES THE COLD IRON WATCH STAND?
|
FWD & AFT ENGINE ROOMS.
|
|
WHAT IS THE PURPOSE OF THE SOUNDING & SECURITY WATCH?
|
CONDUCTS A CONTINUOUS PATROL OF UNMANNED SPACES TAKING PERIODIC SOUNDINGS OF TANKS,
PHYSICAL SECURITY OF ASSIGNED AREAS, REPORTS FIRES, FLOODING, SABOTAGE & THEFT TO DCWS |
|
THE AUX ROVER MONITORS:
|
AIR COND & REEFER SYS
|
|
WHAT WATCHES ARE IN THE FWD & AFT MMR ENG OPERATING STATIONS (EOS)?
|
EOOW (FWD EOS/MAIN CONTROL), SPACE SUPERVISOR, BOILER CONTROL OPERATOR (BCO), ELEC PLANT SUP (EPCP/EMOW)THROTTLE MAN
|
|
FIRE MARSHAL IS RESPONSIBLE FOR?
|
MONITOR SHIP'S FIRE FIGHTING CAPABILITY, PREVENTS & ELIMINATES FIRE HAZARDS
|
|
WHO IS THE CHENG?
|
CDR DYKEMA
|
|
WHO IS THE MAIN PROPULSION ASSISTANT?
|
LCDR PATTERSON
|
|
WHO IS THE DAMAGE CONTROL OFFICER?
|
CHENG
|
|
HOW MANY SSTG'S ARE ON THE BOXER?
|
5
|
|
HOW MANY GENERATORS ARE ON BOARD BOXER?
|
7
|
|
HOW MANY SHIP SERVICE EMERGENCY DIESEL GENERATORS (SSEDG) ARE ON BOARD BOXER?
|
2
|
|
WHAT IS THE PURPOSE OF THE SSEDG'S?
|
TO PROVIDE EMEG POWER TO ELEC DISTROBUTION SYS IF MAIN STEAM IS LOST, USING A COMBUSTION ENGINE AS A PRIME MOVER.
|
|
SSTG'S RATINGS:
|
2500 KW, 4009 AMPS, 450 VAC, 60 HZ, PHASE
|
|
SSEDG'S RATING:
|
2000 KW, 3210 AMPS, 60 HZ, 3 PHASE
|
|
HOW MANY SWITCH BOARDS DOES BOXER HAVE?
|
7
|
|
WHERE IS #5 SWITCH BOARD LOCATED?
|
AFT MMR
|
|
WHERE IS #3 SWITCH BOARD LOCATED?
|
AUX MACHINERY ROOM (AMR)
|
|
HOW MANY EMERG SWITCH BOARDS DOES THE BOXER HAVE?
|
2
|
|
WHERE ARE THE EMERG SWITCH BOARDS LOCATED?
|
#1 FWD DIESEL & #2 IN AFT DIESEL
|
|
HOW MANY SHORE POWER RECEPTACLES ARE ON THE BOXER?
|
30
|
|
HOW MANY CABLES FOR SHORE POWER DOES THE BOXER USE?
|
20
|
|
WHAT ARE THE SHORE CABLES RATED AT?
|
400 AMPS
|
|
WHERE ARE THE SHORE POWER SWITCH BOARDS LOCATED?
|
FWD SHORE POWER SWITCH BOARD IS IN AMR &
AFT SHORE POWER SWITCH BOARD IS IN AFT DIESEL GEN RM |
|
HOW MANY 400HZ CONVERTERS ARE ON BOARD BOXER?
|
5
|
|
WHAT ARE 400HZ CONVERTER UNITS USED FOR?
|
CONVERT 60HZ TO 400HZ FOR SYS
|
|
WHAT IS ABT USED FOR?
|
TRANSFERS LOAD TO ANOTHER (ALTERNATE) SOURCE WHEN IN NORMAL POWER IS LOST AUTOMATICALLY
|
|
WHERE IS #3 SWITCH BOARD LOCATED?
|
AUX MACHINERY ROOM (AMR)
|
|
HOW MANY EMERG SWITCH BOARDS DOES THE BOXER HAVE?
|
2
|
|
WHERE ARE THE EMERG SWITCH BOARDS LOCATED?
|
#1 FWD DIESEL & #2 IN AFT DIESEL
|
|
HOW MANY SHORE POWER RECEPTACLES ARE ON THE BOXER?
|
30
|
|
HOW MANY CABLES FOR SHORE POWER DOES THE BOXER USE?
|
20
|
|
WHAT ARE THE SHORE CABLES RATED AT?
|
400 AMPS
|
|
WHERE ARE THE SHORE POWER SWITCH BOARDS LOCATED?
|
FWD SHORE POWER SWITCH BOARD IS IN AMR &
AFT SHORE POWER SWITCH BOARD IS IN AFT DIESEL GEN RM |
|
HOW MANY 400HZ CONVERTERS ARE ON BOARD BOXER?
|
5
|
|
WHAT ARE 400HZ CONVERTER UNITS USED FOR?
|
CONVERT 60HZ TO 400HZ FOR SYS
|
|
WHAT IS ABT USED FOR?
|
TRANSFERS LOAD TO ANOTHER (ALTERNATE) SOURCE WHEN IN NORMAL POWER IS LOST AUTOMATICALLY
|
|
HOW MANY 400 HZ CONVERTERS ARE ON BOARD BOXER?
|
5
|
|
WHAT ARE 400 HZ CONVERTER UNITS USED FOR?
|
CONVERT 60 HZ TO 400 HZ SYS SUCH AS RADAR, GYROCOMPASS, SATELITE
|
|
WHAT IS AN ABT USED FOR?
|
TRANSFERS LOAD TO ANOTHER (ALTERNATE) SOURCE WHEN NORMAL POWER IS LOST AUTOMATICALLY
|
|
WHAT DOES MBT STAND FOR?
|
MANUAL BUSS TRANSFER
|
|
WHAT ARE THE COLS IN THE DEGAUSSING SYSTEM?
|
A COIL, M COIL, FIQI COIL, FPQP COIL
|
|
WHAT IS THE PURPOSE OF THE DEGAUSING SYSTEM?
|
TO MAKE THE SHIP MAGNETICALLY INVISIBLE BY REDUCING THE SHIPS MAG SIG THROUGH THE WATER
|
|
WHERE IS THE DEGAUSING SWITCH BOARD?
|
FWD IC 5-47-0-C
|
|
WHAT TYPES OF DIESELS ARE ON BOARD BOXER?
|
ALCO (AMERICAN LOCOMOTIVE CORP) 251C, V16, 2800 HP
|
|
HOW MANY AC'S ARE ON BOARD BOXER?
|
6
|
|
WHERE IS # 3 & 4 AC UNITS?
|
AMR
|
|
WHAT CLASSIFICATION OF AC UNITS ARE ON BOXER?
|
300 TON, CENTRIFUGAL (TYPE COMPRESSOR)
|
|
WHAT TYPE OF REFRIDGERANT DOES THE 300 TON AC USE?
|
R-114
|
|
WHAT IS THE PRIMARY MISSION OF THE AC UNIT?
|
COMBAT SYS EQUIP COOLING
|
|
WHAT ARE THE MAIN COMPONENTS OF THE 300TON AC UNITS?
|
COMPRESSOR, CONDENSER, RECEIVER, OFRIFICE PLATE
|
|
WHAT DOES THE CHILL WATER PUMP DO?
|
MOES CHILL WATER FROM CHILLER TO SYS (COMBAT SYS HEAT EXCHANGERS)
|
|
HOW MANY "RIFER" (REFRIGERATION UNITS) ARE ON BOARD BOXER?
|
3
|
|
WHAT TYPE OF RIFER UNITS ARE ON BOXER?
|
5.5 TON, RECIPROCATING (TYPE COMRESSOR)
|
|
WHAT REFRIGERANT IS USED FOR THE RIFER UNITS?
|
R-12
|
|
WHAT IS THE PURPOSE OF THE RECEIVER?
|
STORES LIQUID R-12 FOR THE RIFER & R-114 FOR THE AC'S
|
|
WHAT IS THE USE OF TXV VALVE?
|
CONTROLS THE FLOW OF R-12
|
|
NUMBER OF FREEZE BOXES ON BOARD BOXER?
|
1
|
|
WHAT IS THE PURPOSE OF THE FREEZE BOX?
|
TO STORE FROZEN MEAT
|
|
WHAT UNIT IS USED TO STORE FRUIT AND VEGI'S (35 TO 40 DEGREES F)?
|
THE CHILL BOXES
|
|
HOW MANY CHILL BOXES DOES BOXER HAVE?
|
2
|
|
WHAT IS THE PURPOSE OF THE THAW BOX?
|
TO THAW FROZEN FOOD
|
|
WHAT IS THE PURPOSE OF BALLAST CONTROL?
|
RAISES & LOWERS THE SHIP FOR WELL DECK OPS & CORRECT LIST AND TRIM
|
|
WHEN LOWERING THE SHIP IN THE WATER, THAT IS CONSIDERED?
|
BALLASTING
|
|
WHAT 2 LOCATIONS CAN YOU CONTROL THE BALLAST OF THE SHIP?
|
DCC & WELL DECK CONTROL
|
|
HOW MANY FLOODING & BLOWING TANKS ARE ON BOARD BOXER?
|
27
|
|
HOW MANY RAPID FILL BALLASTING TANKS ARE ON BOARD BOXER?
|
7
|
|
HOW MANY DBAC COMPRESSORS ARE ON BOARD BOXER?
|
10
|
|
WHAT ARE THE TYPES OF FUEL OIL ON BOARD BOXER?
|
F-76, DFM, F-44, JP-5
|
|
WHAT TYPE OF FUEL OIL DOES THE BOILER USE?
|
F-76 & DFM
|
|
WHAT TYPE OF FUEL OIL DOES SSEDG USE?
|
JP-5
|
|
WHAT EQUIP USES JP-5?
|
AIRCRAFTS, EDG, LCAC, SMALL BOATS, & VEHICLES
|
|
NUMBER OF FUEL SERVICE PUMPS IN THE MAIN SPACES?
|
4
|
|
NUMBER OF FUEL OIL SERVICE TANKS FOR EACH MAIN SPACE?
|
2
|
|
NUMBER OF LUBE OIL SERVICE PUMPS?
|
6
|
|
WHERE IS # 2 LUBE OIL PURIFIER?
|
FWD MMR
|
|
TYPE OF LUBE USED FOR MAIN PROPULSION?
|
2190
|
|
HOW MUCH F-76 CAN BOXER HOLD?
|
1,900,000 GALLONS
|
|
HOW MANY JP-5 STORAGE TANKS ARE ON BOARD BOXER & TOTAL CAPACITY?
|
7 & 460,000 GALLONS
|
|
WHAT IS THE CLASSIFICATION OF THE STEERING GEAR SYS?
|
ELECTRO HYDRAULIC, DOUBLE ACTING SINGLE RAM
|
|
WJAT IS THE FUNCTION OF THE STEERING SYS?
|
POSISTION RUDDERS IN RESPONSE TO HELM
|
|
LIST COMPNENTS OF THE STEERING SYS:
|
HELM, STEERING GEAR MOTORS, SG PUMPS, SG UNITS, RAM ASSEMBLY, RACK & PINION FOLLOW UP ASSEM, TRICK WHEELS, EMERG GEAR PUMPS, HAND PUMP
|
|
WHAT ARE THE DIFFERENT METHODS OF STEERING CONTROL?
|
HELM, AUTO PILOT, TRICK WHEEL, TRICK WHEEL STAND BY STEERING UNIT, EMERG STEERING GEAR UNIT, HAND PUMP, ENGINE ORDERS FROM EACH SHAFT WITH RUDDER A "0"
|
|
WHAT IS THE PURPOSE OF CHT?
|
TO PREVENT THE OVERBOARD DISCHARGE OF UNTREATED OR INADEQUATELY TREATING SEWAGE IN NAVIGABLE WATERS OF US OR OTHER COUNTRIES
|
|
WHAT ARE THE 3 MODES OF CHT SYSTEM?
|
IN PORT
TRANSIT AT SEA |
|
WHAT CHOPS THE SOILED WASTE ENTERING CHT TANK?
|
COMMINUTORS
|
|
WHAT IS THE LOCATION OF #1 SEWAGE TANK AND HOW MANY GALLONS CAN IT HOLD?
|
6-37-0-W & 26,000 GALLONS
|
|
WHAT IS THE FUNCTION OF THE ASPIRATOR?
|
REDUCES TOXIC AND EXPLOSIVE GASES FROM BUILDING UP INSIDE TANK
|
|
WHAT IS THE FUNCTION OF SEWAGE PUMPS?
|
SEWAGE PUMPS TRANSFER CHT OVERBOARD UNDERWAY & TO THE RISERS INPORT
|
|
HOW MANY CHT PUMPS ARE ON BOXER?
|
4
|
|
WHERE ARE # 3 & 4 CHT PUMPS?
|
SEWAGE PUMP ROOM #2 (5.5-76-1-E)
|
|
WHAT IS EQUIPMENT IS NEEDED FOR A SEWAGE SPILL?
|
SWABS, BUCKETS, & SPONGES. SCBA OR OBA, WARM WATER WITH WESCODINE (PERSONNEL)
WARM WATER WITH BETADINE (EQUIPMENT) |
|
WHAT PPE IS NEEDED FOR SEWAGE SPILL?
|
DISPOSIBLE CHEM GLOVES, RUBBER GLOVES, RUBBER BOOTS, FACE SHIELD
|
|
HOW MANY HPAC'S ARE ON BOXER?
|
2
|
|
WHAT SERVICES REQUIRE HP AIR?
|
AIR CRAFT ELEVATOR, DIESEL STARTING SYS, HP TO LP VITAL AIR REDUCERS FOR MAIN SHAFT INFLATABLE SEALS
HP TO LP REDUCERS FOR JP-5 PUMP ROOMS |
|
WHAT ARE THE LOCATIONS OF BOTH HPAC'S?
|
#1 HPAC IS IN THE FWD COMPRESSOR ROOM 5-47-0-E #2HPAC IS IN THE AFT COMPRESSOR ROOM 4-97-2-E
|
|
WHAT PSI IS HP AIR?
|
3000 PSI
|
|
HOW MANY LPAC'S DOES BOXER HAVE?
|
8
|
|
IS 1A LPAC IN FWD MMR?
|
NO
|
|
WHAT LPAC IS IN THE AFT MMR?
|
2D
|
|
LP AIR COMPRESSORS MAINTAINS ____ PSI?
|
125 PSI
|
|
WHAT ARE THE 2 SYS THAT USE VITAL AIR?
|
ELECTRONIC EQUIPMENT (COMBAT SYS) & CONTROL AIR IN MAIN SPACES
|
|
Where are upper motor neurons located?
Name the two tracts for these neurons. Example disease in upper? (3) |
-in CNS
–corticospinal, extrapyramidal –CVA, cerebral palsy, multiple sclerosis |
|
WHAT IS THE FUNCTION OF THE PRIORITY VALVE?
|
SEPERATE VITAL AIR FROM NON-VITAL AIR SYS WHEN PRESSURE DROPS
|
|
WHAT PSI IS THE PRIORITY VALVE SET AT?
|
85 PSI
|
|
WHAT CLASSIFICATION ARE THE EVAP'S?
|
6 STAGE, LOW PRESSURE, FLASH TYPE, 100,000 GALLONS OF DISTILLED WATER PER DAY EACH
|
|
WHERE IS #2 EVAP LOCATED?
|
AFT MMR
|
|
WHAT DIFFERENT TYPES OF WATER DO WE PRODUCE?
|
POTABLE WATER, BOILER/FEED WATER, DE-MINERALIZED WATER
|
|
WHAT IS DE MINERALIZED WATER USED FOR?
|
ELECTRONIC COOLING WATER, HARRIER WASH DOWN, RESERVE FEED WATER
|
|
WHAT IS THE FUNCTION OF THE POTABLE WATER AND TRANSFER SYS?
|
PROVIDE QUALITY WATER FORE USE THROUGH SHIP, PROVIDE MEANS TO TRANSFER POTABLE WATER ON & OFF SHIP
|
|
TRUE OR FALSE, WE HAVE 6 POTABLE WATER PUMPS?
|
TRUE, 1 & 2 IN FWD MMR, 3 & 4 IN AFT MMR, 1 &2 POTABLE WATER BOOSTER PUMPS LOCATED ON THE 02 LEVEL
|
|
WHAT IS THE PURPOSE OF POTABLE WATER BOOSTER PUMPS?
|
TO SUPPLY ADEQUATE PRESSURE TO THE ISLAND
|
|
HOW MANY POTABLE WATER RISERS ARE ON BOARD BOXER & WHERE ARE THEY?
|
3, RAS STATION 1 (FLIGHT DECK) RAS STATION 5 (1-90-1-Q) OOD STATION 2 (2-65-2-A)
|
|
WHAT PURPOSE ARE THE POTABLE WATER RISERS?
|
TO CONNECT SHORE TO SHIP & SHIP TO SHIP
|
|
WHAT DOES THE BROMINATOR FOR THE POTABLE WATER SYS?
|
INJECT BROMINE INTO THE POTABLE WATER TO KILL BACTERIA
|
|
HOW MANY POTABLE WATER TANKS ARE ON BOARD BOXER?
|
6
|
|
WHAT IS THE TOTAL POTABLE WATER CAPICITY IN GALLONS?
|
184,000 GALLONS
|