A room equipped with a shower or bathtub is a ________________.
Bathroom
Fixture connections that require the removal of an access panel for servicing are considered ________________.
Accessible
That part of the lowest piping of a drainage system that receives the discharge from soil, waste, and other drainage pipes inside the walls of the building and conveys it to a point 2 feet outside the building wall is a _______________________.
Building Drain
A vertical vent that is a continuation of the drain to which its connects is a __________________________.
Continuous Vent
A horizontal drain that is sized to provide free movement of air above the flow line of the drain is called a __________________________.
Combination waste and vent system
The length along the centerline of the pipe and fittings is the ___________________.
Developed Length
A device integrated within an air accumulator vessel that is designed to discharge a predetermined quantity of water to fixtures for flushing purposes is a (an) ___________________.
Flushometer Tank
The combination of fittings that may be used to make an offset and is considered a vertical pipe are ___________________________.
1 - 45 degree and 1- 60 degree
Water that is safe for people to drink is referred to by this code as ______________________________.
Potable Water
By code definition, a stack is always _____________________.
Vertical
A vent that also serves as a drain is a (an) ______________________.
Wet Vent
A pipe that makes an angle of not more than 45 degrees with the vertical is considered _________________________.
Vertical
The vertical depth of a trap seal is measured from ___________________.
The crown weir to the top of the dip of the trap.
A mixing valve that senses outlet temperature and compensates for the fluctuations in the incoming hot or cold water temperature is a ________________________.
Thermostatic (temperature control) valve
The restroom facilities in a private day care center are classified as public use. T/F
True
The discharge from clinical sinks and conveyed to the building drain is defined as a waste pipe. T/F
False
A combination building sewer is (a) _________________.
Building sewer that conveys both sewage and storm water.
PEX is the definition for ______________________
Cross-linked Polyethylene
The lowest portion of the inside of a horizontal pipe is called the ________________________.
Invert
The part of the horizontal piping of a drainage system that begins _____ feet downstream from the last mobile home site and conveys it to a public sewer is called a mobile home park sewer.
2
A device and system of piping that maintains a water seal in a remote trap is called a trap primer. T/F
True
Static pressure is a pressure existing without any flow. T/F
True
An unconfined space is a room or space having a volume equal to at least ____ of the aggregate input rating of all the fuel-burning appliances in that space.
50 cubic feet per 1,000 Btu/hr
A permanently installed mechanical device, other than an ejector, for removing sewage or liquid wastes from a sump is called a sewage pump. T/F
True
A standard that is an extensive compilation of provisions covering broad subject matter is the definition for ____________________.
Code
The principle artery of the venting system to which branches may be connected is called the _____________________.
Main Vent
A joint obtained by the joining of metal parts with metallic mixtures or alloys that melt at a temperature up to and including 840° F is a __________________________.
Soldered Joint
The organization, office, or individual responsible for enforcing the requirements of a code or standard is the _________________________.
Authority Having Jurisdiction
That portion of a drainage system that does mot drain by gravity into the building sewer is known as a _______________________.
Building Subdrain
A pipe inside a building that conveys storm water from the roof to a storm drain is called a (an) ___________________________.
Conductor
An outlet on a boiler to a permit emptying or discharging of sediment is called a (an) ___________________________.
Boiler Blowoff
A pressure surge-absorbing device operating through the compressibility of air is called a (an) _____________________.
Air Chamber
A device installed in a drainage system to prevent reverse flow is a __________________.
Backwater Valve
Any pressure less than that exerted by atmosphere is a (an) _______________________.
Vacuum
A document, the main text of which contains only the mandatory provisions using the word "shall" to indicate requirements, is best described as a ___________________.
Standard
Unsanitary and insanitary share the same meaning. T/F
True
When a backflow prevention device does not bear a critical level marking, the part of the device that shall constitute the critical level is the ______________________.
Bottom