Screws or bolts for securing floor-mounted fixtures shall be __________________.
|
Brass
|
|
Fixtures having concealed slip-joint connections shall be provided with ____________________.
|
A utility space or access panel
|
|
The overflow pipe from a fixture shall be connected on the ____________________.
|
House or inlet side of the fixture
|
|
Continuous wastes and fixtures tailpieces may be seamless drawn brass not less than __________.
|
1-1/2 inches OD
|
|
The diameter of a waste and overflow for a bathtub shall not be less than _________________________.
|
1-1/2 inches OD
|
|
No dry or chemical closet (toilet) shall be installed in any building used for human habitation unless first approved by the _________________________.
|
Health Officer
|
|
Tanks flushing more than one urinal shall be ________________.
|
Automatic in operation
|
|
Every water supply to a urinal shall be protected by an approved _____________________.
|
Vacuum Breaker
|
|
Trough urinals shall be _____________________.
|
Prohibited
|
|
To provide a watertight joint in the floor, shower drains and floor drains are required to be ______________________.
|
Suitably Flanged
|
|
With two noted exceptions, all shower compartments and receptors shall be capable of encompassing a __________________ diameter circle.
|
20-inch
|
|
The curb or threshold of a shower compartment may be eliminated __________________________.
|
To comply with the accessibility standards.
|
|
Shower pan linings may be constructed with ________________.
|
15 pounds asphalt felt
|
|
Joints in copper shower pan liners shall be ___________________.
|
Soldered or brazed
|
|
Drinking fountains shall not be installed in ___________________.
|
Public toilet rooms
|
|
Water closets set side by side shall be no closer than ________________________.
|
30 inches center to center
|
|
The minimum distance from a side wall or partition to the center of a urinal shall be _________ inches.
|
12
|
|
Manually controlled flushometer valves shall be used to flush more than ________________________.
|
One urinal
|
|
Automatically controlled flushometer valves may be substituted for ________________________.
|
Flush tanks
|
|
The joint of a wall-hung lavatory, where it is in contact with the wall, shall be _______________________.
|
Watertight
|
|
Galvanized sheet steel of not less than 16 U.S. gauge may be used to make dish-washing sinks for ___________________________.
|
Restaurants
|
|
Gutters in public shower rooms shall be sloped not less than _______________________.
|
2 percent
|
|
Wall-hung lavatories shall be supported by ______________________.
|
Metal hangers
|
|
The tailpiece diameter for lavatories and drinking fountains shall not be less than ___________________.
|
1-1/4 inches
|
|
A solidly formed sub-base is required so as to pitch shower pan linings to weep holes in the sub-drain with a fall of __________________.
|
1/4 inch per foot
|
|
Approved strainers having an approved waterway area are not required for _________________________.
|
Urinals
|
|
Showers in all buildings shall be provided with individual control valves of the _____________________.
|
Pressure balance type and the thermostatic mixing valve type
|
|
The clear space in front of any water closet or bidet shall not be lass than ___________________.
|