Name the major vents in a plumbing system: |
Vent header, vent stack, stack vent |
|
What table are dual vents sized from? |
2.5.7.1. |
|
Name the vents that must be full size throughout their entire lengths: |
Stack vents, vent stacks, continuous vents, relief vents |
|
Name the vents that must be increased as the load increases: |
Branch vents and vent headers |
|
Continuous vents are a _________ of a/an ______or ______. |
Vertical extension Branch Fixture Drain |
|
How are sump vents sized? |
One size smaller than largest branch or fixture drain draining into the sump , not less than 2”, no greater than 4” |
|
The developed length of a Branch is measured from the ______________ ________ to its termination in a/an _________ ______ or open air. |
Farthest soil pipe connection Major Vent |
|
All vents must conform to table_______, the mother of Vent tables |
2.5.7.1. |
|
When sizing an individual vent use table____ |
2.5.7.1. |
|
Every roof increaser must be _________than the Vent it serves , but never less than ____” |
One size larger 3” |
|
Continuous vents are sized from tables ____and table ______ |
2.5.7.1. 2.5.8.3. |
|
The diameter of a stack vent is sized by table 2.5.8.4. but May not be less than ___________ of the ________________ at its base. |
One half the size Soil or waste stack |
|
The longest allowable trap arm is found in a _____” __________. |
4” floor drain |
|
The minimum size of a roof increaser is __X___” |
11/4”X3” |
|
Wet vents are sized using table ________ |
2.5.8.1. |
|
A fixture or branch , from separately vented fixtures, not exceeding a hydraulic load not greater than 2 fixtures units may connect to a _____ vent downstream of the _______ Vent provided its _____is included when sizing the _____ portion. |
Wet vent Continuous vent Load Wet vent |
|
What is the density of water? |
.433 |
|
Hydraulic load and trap size of a Lavatory? |
1 with 11/4” trap |
|
Hydraulic load of a water closet? |
4 6 w/ flush valve |
|
Hydraulic load and trap size of a bathtub, shower, or bathtub with shower? |
11/2” |
|
Hydraulic load and trap size of a sink? |
11/2” |
|
Hydraulic load of a bathroom group |
6 8 w/ direct flush valve |
|