Name the major vents in a plumbing system:

Vent header, vent stack, stack vent

What table are dual vents sized from?

2.5.7.1.

Name the vents that must be full size throughout their entire lengths:

Stack vents, vent stacks, continuous vents, relief vents

Name the vents that must be increased as the load increases:

Branch vents and vent headers

Continuous vents are a _________ of a/an ______or ______.

Vertical extension


Branch


Fixture Drain

How are sump vents sized?

One size smaller than largest branch or fixture drain draining into the sump , not less than 2”, no greater than 4”

The developed length of a Branch is measured from the ______________ ________ to its termination in a/an _________ ______ or open air.

Farthest soil pipe connection


Major Vent

All vents must conform to table_______, the mother of Vent tables

2.5.7.1.

When sizing an individual vent use table____

2.5.7.1.

Every roof increaser must be _________than the Vent it serves , but never less than ____”

One size larger


3”

Continuous vents are sized from tables ____and table ______

2.5.7.1.


2.5.8.3.

The diameter of a stack vent is sized by table 2.5.8.4. but May not be less than ___________ of the ________________ at its base.


One half the size


Soil or waste stack

The longest allowable trap arm is found in a _____” __________.

4” floor drain

The minimum size of a roof increaser is __X___”

11/4”X3”

Wet vents are sized using table ________

2.5.8.1.

A fixture or branch , from separately vented fixtures, not exceeding a hydraulic load not greater than 2 fixtures units may connect to a _____ vent downstream of the _______ Vent provided its _____is included when sizing the _____ portion.

Wet vent


Continuous vent


Load


Wet vent

What is the density of water?

.433

Hydraulic load and trap size of a Lavatory?

1 with 11/4” trap

Hydraulic load of a water closet?

4


6 w/ flush valve

Hydraulic load and trap size of a bathtub, shower, or bathtub with shower?

11/2”

Hydraulic load and trap size of a sink?

11/2”

Hydraulic load of a bathroom group

6


8 w/ direct flush valve