A floor drain is permitted to be connected to a storm water waste system, provided that it’s located where it can only receive ______________ |
Clear water water waste or storm water |
|
Minimum length of horizontal offset in a soil or waste stack that receives more that 30FU or discharge from 2 or more stories? |
1.5m |
|
Where a vent pipe is connected into the suds pressure zone , no other vent pipe shall be connected to said vent pipe within _____ |
The height of the suds pressure zone. |
|
No other fixture may connect to a lead bend or stub that serves a ______ |
Water closet. |
|
An overflow from a rainwater tank shall not be directly connected to a ______ |
Drainage system |
|
Equipment discharging waste with organic solids shall not be located _________ of a__________. |
Upstream Grease interceptor |
|
What floor drains or fixtures are not permitted to be connected to the drainage system? |
Oil transformer vaults High voltage rooms Where flammable,dangers or toxic chemicals are stored |
|
To what temperature must waste be cooled to before it is discharged into the drainage system? |
170•F, 75•C |
|
Fixtures that discharge fats, oils and grease in a public kitchen must discharge through a ___________ |
Grease interceptor |
|
An interceptor with an effective water seal of not less than ______ is permitted to serve as a trap. |
38mm |
|
When storm water is connected to a combined sewer, a _______ shall be installed between any opening in the system, unless the opening is the upper end of a leader that terminates _____________ and ___________. |
Trap At a roof only used for weather protection Not less than 1m above or 3.5m away from any air inlet, openable window or door. |
|
Where freezing could cause storm drainage to freeze a _______ with a _______ shall be installed in a heated location . |
Trap Clean out |
|
Sewage sump tanks that don’t operate automatically must have the capacity to sufficiently hold for_______ of accumulation of liquid. |
24 hrs |
|
Maximum _______ change in direction on a horizontal drain between _______ |
135• Clean outs |
|
the discharge from a sewage sump pump shall be equipped with a _________, _________ and a ___________ installed in that sequence in the direction of discharge . |
Union Check valve Shut off |
|
Nominally Horizontal piping that is inside a building shall be braced to prevent __________ and _______ and to control the effects of _______ |
Swaying and buckling Thrust |
|
ABS or PVC plastic piping shall be supported every ____m or ___feet and at the end of _______ or _____ and at changes in direction or elevation. |
1.2m 4 feet Branches or fixture drains |
|
Cast Iron Pipe shall be supported every _____ m or _____” and at or adjacent to each ____ or _____. |
3m 10feet hub or Joint |
|
Where a fixture or device is ____________, the connections shall be made by terminating the fixture drain above the ________________ of a directly connected fixture to form an __________ |
Indirectly connected Flood level rim Air Break |
|
Size of an air break? |
1 pipe diameter but not less than 1” or 25mm |
|
Nominally Horizontal piping underground shall be supported in a base that is ______ and ______ u see the whole pipe. |
Firm and continuous |
|
Under ground pipes shall be back filled and tamped to a height of __________over the top of the pipe. |
300mm or 12” |
|
What |
Risk of damage to the building Condensation |
|
Except for acid traps , every trap shall have a seal depth of not less than _____mm or ________. |
38mm 11/2” |
|
What are the two provisions that must be met to allow one trap to serve a group of floor or shower drains , a group of washing machines or a group of laboratory sinks? |
1. Same room 2. Cannot receive food or organic waste. |
|
ABS or PVC plastic piping shall be supported every ____m or ___feet and at the end of _______ or _____ and at changes in direction or elevation. |
1.5m 4 feet Branches or fixture drains |
|
Keep |
Going |
|
Steel pipe 6 inches in diameter or greater shall be supported every ____ |
3.75 m |
|
All steel pipe with a diameter 5” or less shall be supported every ______feet or _____m |
2.5 m 8ft |
|
Nominally Horizontal piping underground shall be supported in a base that is ______ and ______ throughout the whole pipe. |
Firm and continuous |
|
Rods supporting hangers for pipe over 4” in size must be ______ in diameter |
13mm or 1/2” |
|
piping used as an internal leader which may be subject to condensation shall be installed in a manner that limits the _____________ due to ________. |
Risk of damage to the building Condensation |
|
Vertical piping must be supported at its ______ and at the floor level of _______ by rests ( riser clamps ) each which can bear the weight of the ______ that is between bit and the rest above it. |
Base Alternate stories Pipe |
|
The maximum spacing of vertical supports shall be ______ |
7.5 m |