- Front
- Back
during thoracotomy, which rib can move more? (cranial or caudal)
|
cranial moves more
|
|
should you place cranial and caudal drapes first or laterals?
|
Cranial and caudal first, then laterals
|
|
what layer is most important in holding incisions closed?
|
submucosa
|
|
2 common organs to use stay sutures in
|
stomach, bladder
|
|
Absorbable sutures lose strength in __ days
|
60
|
|
surgical gut suture
|
natural origin
-multifilament -lowest tensile strength -highest reactivity -absorbable |
|
Polyglactin 910
|
"Vicryl"
-synthetic -multifilament -absorbable |
|
Polydioxanone
|
"PDS"
-synthetic -monofilament -absorbable, but slow |
|
Poliglecaprone 25
|
"Monocril"
-synthetic -monofilament -absorbable (rapid) |
|
silk
|
natural
-multifilament -best handling characteristics -very reactive -non-absorbable |
|
nylon
|
synthetic
-monofilament or multifilament (mono preferred) -non-absorbable |
|
polymerized caprolactum
|
synthetic
-multifilament -protein outer coat -nonabsorbable -no tensile strength loss (for skin only) |
|
polypropylene
|
synthetic
-monofilament -inert, good knot security (good for skin) |
|
sutures with highest reactivity
|
surgical gut (absorbable)
silk (non-abdorbable) |
|
highest and lowest net tensile strength
|
highest absorbable - polyglyconate
lowest absorbable - surgical gut highest nonabsorbable - stainless steel lowest nonabsorbable - silk |