When shall Breathing Apparatus be worn?

Breathing apparatus shall be worn by all personnel when:


- the atmosphere is hazardous


- the atmosphere is suspected of being hazardous


- the atmosphere may become hazardous


- MFS policies specify


- directed by the IC


- working in a confined space or where access and egress are a concern to the IC



In addition to SCBA, IC shall consider the use of :


- full body harnesses


- rescue lines


- atmospheric monitors / detectors

What is stage one entry control?

- used for initial get to work, IC to initiate stage two ASAP.


- maximum 4 wearers (pump operator is ECO)


- is / may also be used for OVERHAUL or similar situations

What is stage two entry control?

- maximum 10 wearers (5 teams of 2) plus 2 relief workers


- dedicated ECO

Describe the maintenance procedures for SCBA sets

Maintenance A


- when taking over a SCBA set



Maintenance B


- after using SCBA


- to be completed asap after use



Maintenance C


- carried out by BA techs only, and to manufacturers specs