Manufacturer

Sundstrand APS 2300

First and Second start attempts

START/ON then 60 seconds OFF

Third Start Attempt

START/ON then 5 min OFF

Minimum Starting Temperature

-54°C

Maximum Operation Temperature

ISA +39°C

EGT (Start)

1032°C

EGT (Continuous)

717°C

No time limit in amber on ground/in-flight between

662-717°C

Max Rotor Speed

108%

Maximum Altitude: Electrical

33,000'

Maximum Altitude: Starting

30,000'

Maximum Altitude: ENG Start Assist

21,000'

Maximum Altitude: ECS Bleed

15,000'