• Shuffle
    Toggle On
    Toggle Off
  • Alphabetize
    Toggle On
    Toggle Off
  • Front First
    Toggle On
    Toggle Off
  • Both Sides
    Toggle On
    Toggle Off
  • Read
    Toggle On
    Toggle Off
Reading...
Front

Card Range To Study

through

image

Play button

image

Play button

image

Progress

1/26

Click to flip

Use LEFT and RIGHT arrow keys to navigate between flashcards;

Use UP and DOWN arrow keys to flip the card;

H to show hint;

A reads text to speech;

26 Cards in this Set

  • Front
  • Back

What does a HIGH LIGHT and an automatic shutdown of the APU during normal operation indicate?

Overspeed Condition

When external power and the APU generator PWR switch is in use, the AC Tied light should go off.

True

In the event of an APU, how many possible locations are available to shutdown the APU?

3

Activation of the APU agent discharge switchlight on the APU panel will provide automatic shutdown of the APU.

True

What is the appropriate amount time for the APU inlet door assembly to open?

9 Seconds

External air leakage from the APU heat shield area is allowable.

True

Although it may be started with slats down, how much time do you have to raise them?

30 Sec

When the APU must be operated with access doors open to accommodate maintenance, you need a person with a fire bottle on standby.

True

Automatic shutdown occurs when APU EGT exceeds _______ @ 95% RPM.

621 •C

The APU cannot be operated with LOOPS A & B INOP.

True

If the APU doors are open the fire suppression is not sufficient to put out a fire.

True

What does the HOT LIGHT and an automatic shutdown of the APU during normal operation indicate?

Overtemp Condition

Personnel will position the START CONTROL switch to the “RUN” position for ___ second(s) prior to starting the APU.

2

Press and hold which switchlight to test all lights and digital indicators on the overhead panel?

ANN/DIGT TEST SWITCHLIGHT

When tank #3 FWD boost pump switchlight is not turned on within 2 minutes, the WAP will display caution.

True

What switch causes the APU to shutdown when placed to the off position?

Start control switch

What action should be taken when the APU fails to spool up during battery start?

Reset the APU START C/Bs in the battery compartment.

An APU fire will be indicated by what? 5 EA

Master warning lights, APU on CUE, LOOPS, CAWS, and fire light on APU panel.

What position will the DC X TIE be when using external or APU generator power?

TIE

The APU PWR switch on the electrical panel shall remain on until after the APU has completely shutdown.

True

Radio communications are required during APU operation.

True

APU fuel consumption is ___ lbs per hour.

500

At what’s percent RPM will the APU auto shutdown?

104%

RPM Increases and stabilizes at _______ % RPM.

97-101

What’s indicated as you press LOOPS?

APU LOOPS A & B ON, Fire Light, and CAWS

Starter duty cycle is __ minutes between attempts, no more than __ attempts in 1 hour.

1, 3