Explain the fueltanks

Two tanks, interconnected by a flange. Bladder type held with velcro and nylon chord.


Fuel is always balanced untill 228 Kg is left in both tanks.

What houses the sump plate

A booster pump


Secondary fuel quantity probe with a low level sensor


A drain valve


An electrical waterdrainvalve

Total fuel capacity?

1588 l


1270 Kg

How is the fuel level measured?

By two mainprobes from full to 400KG


Two secondary probes from 400 to empty

When is the FUEL LOW activated?

At 92 Kg remaining in that tank

Explain the fuel distribution

Two boosterpumps deliver fuel to the fuel manifold.


Before the manifold a pressureswitch for opening the crossfeed.


A oneway checkvalve prevents fuel to be able to return to the tank.



The manifold houses:


Two shut off valves and one Xfeed


Two pressure transducer measure fuelpress after the SOV


From here the fuel is delivered to the engine

How is the fuelflow determined?

The EEC calculates it from Idle (Ng above 62%) in conjuction with ADS TAS data

Explain the FCU

Fuel Computer Unit:


Monitors quantity


Procides exitation current to measure level and converts it in to KG


Sends fuel quantity to MAU 1 and 2


Two independend Low level Detector is connected to two Low Level Sensor (thermister type at 92Kg)

Important fuel figures:

Full 1270 (2x635)


From 800 (2x400) secondary part


228 residual for each tank only (non transferrable)


92 fuel low


8kg unused.

When is the fuel oresented in a grey schale?

When unusable:


228 or less with xfeed open and 1 BP on.

What is xfeed logic in “NORM”

2 BP: Closed


1 BP: open


0 BP: open

What does the ventline and the flame arrestor do?

Ventline is connected to the opposite side to prevent leaks on roll over

What is are the test for the fuelsystem?

Start up BIT


Continuous BIT


On ground full BIT of 6 sec

What happens with an FCU fail?

The onside fuel cannot be measured so the total cannot be calculated. LLD still works.


Untill 228 Kg the fuel can be doubled roughly.

Explain the possible CAS captions