What are the components of the AC system |
Vapor cycle cooling system AIR cycle unit/air cycle machine Pressurization control Electric heat subsystem |
|
Components of the vccs |
Load shed controller Compressor module Condenser/heat exchanger assembly Forward evaporator blower Aft evaporator blower Avionics rack evaporator Avionics backup blower unit |
|
The vccs runs on... when on the ground and on... when airborne |
28vdc gpu Right nonessential bus |
|
The load shed controller limits right load nonessential bus operations under what conditions |
Engine starts Windshield device system operation Horizontal device operation |
|
If the vccs is knocked offline what do you press |
Australia temp control switch to the Off/reset and then back to AUX COOL |
|
At what temp will will the vccs not operate |
20F |
|
If the low pressure refrigerant line falls below... for more than... seconds the vccs will not operate |
10psi, 20 seconds |
|
When will the OVER PRESSURE LOCKOUT switch operate and the vccs will not operate |
High pressure refrigerant line exceeds 320psi |