In air distribution systems, the three basic categories of fans are |
centrifugal, special design , and axial |
|
What are the width and inlet constructions of centrifugal fans? |
SWSI and DWDI |
|
The purpose of vanes of a vaneaxial fan is to |
straighten out the airs spiraling motion |
|
A fan drive is an assembly made up of |
a motor sheave, fan sheave, and connecting belts |
|
To prevent needless problems to your HVAC equipment, which item should you check during V-belt inspection? |
Proper alignment |
|
The most common size v-belts used in HVAC systems are |
A through D |
|
What is generally the proper tension for the top side of fan belts? |
1/2 to 1 inch deflection |
|
A single-duct system become a low-press reheat system when |
heating coils are inserted into the duct system downstream of the cooling coils |
|
The individual zone or space control is provided in an induction system by |
heating the secondary air |
|
which multiple-path system uses a mixing valve to control zone temp by mixing warm and cold air in proper rotation |
dual-duct |
|
what is one way to reduce energy cost of a dual-duct system with no cooling load? |
operate the system as a single zone |
|
which multiple-path system meets the requirements of the different zones by mixing cold and warm air through zone dampers at the central heat, ventilation, and HVAC unit? |
multizone |
|
The supply pressure loss data for equipment used in piping systems normally come from |
manufacturers |
|
what is static head? |
pressure due to the weight of the fluid above the point of measurement |
|
how many intakes does the single-suction pump impeller have |
one |
|
which type pump casing collects water from the impeller and discharges it parallel to the pump shaft? |
Diffuser |
|
some leakage at the packing gland of a pump is needed to |
lubricate and cool the area between the material and shaft |
|
pumps with mechanical seals |
must be run dry |
|
Destructive pitting and wearing of a pump impeller and casing as well as noise and vibration can be caused by |
cavitation |
|
What is normally the cause of vortex in a piping system |
configuration of the piping system |
|
what do manufacturers use to show how pumps respond under different operating conditions |
A performance curves graph |
|
After each major repair to a pump or when there is an indication that the system flow is not correct, what do you check? |
pump performance |
|
what is the maximum allowable working pressure for low-pressure heating boilers with a maximum temperature limitation of 250 degreesF |
160 PSI |
|
what is the usual pressure for medium-pressure heating boilers when the usual design supply temperature is approximately 250 to 350 degF |
150 PSI |
|
what is the maximum allowable working pressure for high-pressure heating boilers with a max temp limit of 450 degF |
300PSI |
|
What would be the acceptable temp and pressure of a chilled-water supply system |
48 degF and less than 125PSI |
|
which piping system is a continuous run of pipe or tbe from the boiler or chilled water supply connection back to the boiler or chiller? |
series-loop |
|
which hydronic distribution system uses a special diverting tee that creates a pressure drop in the main flow to divert a proportion of the main flow to the terminal unit. |
one-pipe |
|
since water flow distance from and to the boiler is virtually the same through any unit, balancing valves require less adjusting on the |
two-pipe reverse return |
|
which hydronic distribution system uses a special three-way valve at the inlet to the coil to admit water from either the hot-or cold water supply in sequence as required. |
three-pipe |
|
when a terminal unit of hydronic distibution system is provided with two independent water coild, one served by hot water, the other by cold water, this is an example of a |
four-pipe system. |
|
If air and other gases are not removed from the hydronic piping flow circuit, they may cause |
air binding |
|
all low points on hyrdronic systems should be equipped with |
drains |
|
when the condensate of a steam system has cooled below the condensing temp this is referred to as |
subcooling
|
|
Because it is necessary to keep a steam system in service at all times, what is installed around the auto temp control valve? |
A bypass |
|
Which steam trap reacts to a difference in the temperature between the steam and condensate? |
thermostatic |
|
which thermostatic trap is not adversely affected by super heated steam? |
Bimetallic |
|
when pressure-reducing valves are used in a steam system, what must also be used? |
Relief devices |
|
In hydronic heating and cooling units, radiators are rated in terms of the square feet of |
equivalent direct radiation |
|
The square feet of equivalent direct radiation of a radiator depends upon radiator |
capacity and configuration |
|
The primary types of baseboard units are |
radiant, radiant-convector, and finned-tube |
|
Hot-water panel heaters include the |
ceiling, wall, and floor panel types |
|
when lubricating unit ventilator fan and motor bearings, you should |
follow the manufacturers recommendations |
|
which duct system terminal unit is supplied with both hot and cold air? |
dual-duct |
|
Because the pressure in the hot and cold ducts of a dual-duct terminal may vary over a wide pressure range due to the demand for the hot and cold air varying throughout the building, it is important to have |
an auto airflow control device |
|
which duct system terminal unit has a manually operated damper that is adjusted when the system is initially balanced and then left in that position to maintain constant airflow? |
single-duct |
|
how does the induction unit circulate air from the room through the coil? |
it induces air through the coil |
|
normally, the basic central station heating, ventilation, and air conditioning equipment in the air/hydroponic unit is located |
outside the conditioned are |
|
In a central station unit, heat recovery equipment may be placed between the outdoor intake and coils, and in mild climates, may replace the |
preheat coil
|
|
The use of a return-air fan in a central station unit is optional but generally is essential for proper operation of |
larger systems |
|
when the ventilation by exhaust method provides ventilation for fan-coil units, the entire building |
is placed in a negative pressure |
|
which combination air/ hydronic unit uses air from a central air-conditioning unit that furnishes the ventilation, required dehumidification, and motive power for including the secondary air? |
induction |
|
what is the most important part of a valve |
throttling nut |
|
what is the most common type of two-position valve used in control applications? |
single-seat |
|
which item is a three way valve that has one input and two outputs? |
diverting |
|
what type of valve normally controls steam-to-water or steam-to-air heat exchangers? |
two-way |
|
which multi-blade dampers use a linkeage that causes the adjacent blades to move in opposite directions? |
opposed |
|
which option best describes a damper flow characteristic? |
relationship between the position of the damper and the percent of air that flows through it |
|
face and bypass control of a heating or coolign coil is done by |
modulating the volume of air through the coil |
|
In what two ways are coils basically constructed? |
Bare tube or pipe and extended surfaces |
|
For a heating steam coil to operate properly, eliminate |
all noncondensables |
|
Before you clean an HVAC coil, what should you do to the ducts in and out of the coil? |
Isolare them |
|
With which residential humidifier does the humidification rate var with the temp, humidity, and velocity of the air? |
pan type |
|
which humidification method is essentially an isothermal process |
steam type |
|
manometers are used with filters to measure the |
pressure drop across the filter |
|
which filter is recommended to remove very fine dust particles from the air? |
Electronic air cleaner |
|
The basic types of supply-air outlets are |
grilles, slot diffusers, ceiling diffusers, and air-distributing ceilings. |
|
For what type of installations are the perpendicular-flow slot diffusers best suited? |
High sidewall and perimeter |
|
which type of heat recovery equipment turns between 2 and 8 revolutions per minute? |
Heat wheel |
|
what type of heat recovery device operates in a manner similar to a heat pipe except for the working fluid? |
coil loops |
|
The output capacity of a heat pump is strongly dependent on the |
available source of heat |
|
What type of heat exchanger is designed for pump flow of water from the boiler through the shell? |
Water |
|
Air in HVAC work is considered and treated as |
an individual gas |
|
What is the formula for calculating the volume of airflow through a duct |
cfm= area x velocity |
|
Which term is a measurment of resistance to the movement of air that is being forced through an HVAC system? |
Static pressure |
|
A velocity-to -static-pressure conversion generally occurs in the |
transition duct at the discharge of a fan |
|
As air flows from the discharge or intake of a fan to the ends of the duct runs, the gauge pressure |
decreases to zero |
|
The system resistance curve is a plot of the |
pressure required to move air through the system |
|
After you level and zero the quarter-inch inclined manometer, connect its hoses to the |
pilot tube |
|
When you attachthe pitot tube to the combination incline and vertical manometer, connect the hose from the left side to the |
total pressure leg of the pitot tube |
|
how is the pitot tube inserted into duct work? |
parallel to and facing the airflow |
|
what is the first step of the general procedure for testing and balancing systems? |
preparing test reports |
|
Under what step of preparing test reports does listing systems in groups, supplies, returns and exhausts come? |
Filling out an air system recap sheet |
|
the last step in fillinf out the fan test report is filling in the |
static pressure drops box |
|
upon taking startup readings during equipment check out, one thing you should listen for is |
bursting or collapsing ducts |
|
Before you balance outlets, what should you check to make sure of the correct amount of airflow? |
total airflow |
|
what is the first step in proportionate balancing? |
spot-check the end outlets closest to the fan |
|
when using the proportionate balancing method, the last step in balancing a low-pressure single zone system is to |
go back to the fan |
|
When you recheck equipment readings what should you do if the total outlet cubit feet per minute is 10 percent or more under or over the design cfm? |
increase or decrease the fan revolutions per minute |
|
In which method of indoor air quality control must you consider the increasing heat load |
ventilation |
|
the orifice-plate flowmeter must be installed with |
a straight length of pipe upstream and downstream of the plate |
|
Which hydronic flowmeter is a variable-orifice flowmeter that combines a flowmeter and balance valve in one unit? |
Circuit tester |
|
"List the valves and terminals in the order the occur" falls under which step of preparing water-balance test reports? |
fill out the flow or pressure-drop water-balance report |
|
"list the coil identification room number in sequence" falls under which step of preparing water-balance test reports |
Fill out the temp water-balance report |
|
What is the first step for taking startup reading s during chilled-and hot water system balancing? |
read the pump static pressure with the pump off |
|
what is one step in balancing water terminals |
read and record initial flows without making adjustments |
|
Exposing an original and a translucent tracing paper to a strong light produces a copy with white lines on a blue background that is called |
a blueprint |
|
the reason an object on a blueprint is scaled to a smaller size is that it can |
be placed on smaller sheets without crowding the views |
|
when a building is divided into subsystems during an energy audit, which subsystems included the plumbing, HVAc and control systems? |
energized subsystem |