  • Back
WHAT IS THE STRIPPING PUMP RATED AT?
50 GPM AT 50 PSI
WHAT IS THE STRIPPING PUMP RELIEF SET AT?
62 1/2 PSI
WHAT IS THE RATED CAPACITY OF THE DEFUEL PUMP?
100 GPM AT 15 PSI
WHAT IS THE RELIEF PRESSURE SET AT ON THE DEFUEL PMP?
28 PSI
WHAT IS THE AUXILIARY PUMP RATED AT?
50 GPM AT 100 PSI
WHAT IS THE RELIEF SET AT ON THE AUXILIARY PUMP?
112 PSI
WHAT IS THE TRANSFER PUMP RATED AT?
200/300 gpm at 50 psi
WHAT IS THE RELIEF SET AT ON THE TRANSFER PUMP?
62 1/2 PSI
HOW MANY BALL BEARINGS LOCATED AND HOW MANY?
TWO BEARINGS LOCATED IN EACH HEAD ASSEMBLY
WHAT IS THE CLEARANCE SET AT ON THE BALL BEARINGS?
0.0125 MM
WHERE DOES THE PRESSURE RELIEF GO BACK TO WHEN IT RELIEVES TOO MUCH PRESSURE?
SUCTION SIDE OF THE PUMP
HOW ARE THE SLIDING VANES KEPT IN CONTACT WITH THE CYCLINDER BORE?
BY CENTRIFUGAL FORCE AND PUSHRODS
ON THE STRIPPING PUMP IT SHOULD NOT BE RUN DRY FOR LONGER THAN HOW MANY MINTUES?
2 MINUTES
WHAT IS THE HORSEPOWER ON THE STRIPPING PUMP?
5 HORSEPOWER
WHAT ARE THE POWER REQUIREMENTS FOR THE STRIPPING PUMP(VOLATAGES)?
440V/60HZ/3 PHASE
WHAT IS THE GEAR RATIO FOR THE STRIPPING PUMP?
3.32:1
HOW LONG SHOULD YOU OBSERVE LEAKAGE FROM THE TELL-TALE HOLE?
30 MINUTES
RELIEFS SHOULD LIMIT PUMP FROM EXCEEDING WHAT %?
125%
BEARINGS ON THE STRIPPING PUMP SHOULD BE REPLACED WHEN RADIAL PLAY REACHES WHAT AMOUNT?
.005 INCHES
WHEN TIGHTENING LOCK NUTS ON THE STRIPPING PUMP HOW MANY FT LBS OF TORQUE ARE REQUIRED?
20 PLUS OR MINUS 5
WHAT IS THE MAX HORSEPOWER ON THE TRANSFER PUMP?
25 HORSEPOWER
WHAT IS THE SUCTION LIFT ON THE TRANSFER PUMP?
15 HG
ON THE TRANSFER PUMP HOW LONG AND AT WHAT TEMPERATURE SHOULD YOU HEAT UP THE BALL BEARINGS?
1 HOUR AT 250 DEGREES
TRANSFER BEARING LOCKNUT SHOULD BE TORQUED TO WHAT FT LBS?
10-20 FT LBS
YOU SHOULD NOT FILL UP THE GREASE PAST WHAT PERCENT?
50%
ON THE STRIPPING PUMP THE OIL IN THE RREDUCTION GEAR SHOULD NTO HEAT PAST WHAT DEGREES?
180 DEGREES

TELLTALE HOLES SHOULD NOT EXCEED HOW MANY DROPS PER DAY?

3 DROPS PER DAY

THE TRANSFER PUMP SHOULD REACH HOW MANY PSI WITHIN HOW MANY MINUTES BEFORE CONSIDERED RUNNING DRY?

15 PSI WITHIN 2 MINUTES

WHAT IS THE CLEARANCE OF THE ROTOR TO THE CYLINDER BORE?

.002 TO .008 INCHES

What do the flexible couplings serve as?

Allow for slight misalignment between pump,gear reducer and motor shaft.

How is the pressure regulated?

Pressure control valve

The defuel pump has a disc that is how many inches to allow what percent of fuel flow back to the suction header?

The disc in the valve has a 5/32 inchdrilled hole to allow 5 percent flow to thedefuel pump suction header when theservice system is in operation.

During inspection of the rotor and shaftassembly you notice that the shaft is bent, whatrepair action should you take?

Change the shaft

What are the four major components of theRotary Vane Pumps?
Cylinder, Head, Pressure ControlValve, and the Rotor and Shaft Assembly
How is the rotor held to the shaft?

Keys and pins