Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
35 Cards in this Set
- Front
- Back
WHAT IS THE STRIPPING PUMP RATED AT?
|
50 GPM AT 50 PSI
|
|
WHAT IS THE STRIPPING PUMP RELIEF SET AT?
|
62 1/2 PSI
|
|
WHAT IS THE RATED CAPACITY OF THE DEFUEL PUMP?
|
100 GPM AT 15 PSI
|
|
WHAT IS THE RELIEF PRESSURE SET AT ON THE DEFUEL PMP?
|
28 PSI
|
|
WHAT IS THE AUXILIARY PUMP RATED AT?
|
50 GPM AT 100 PSI
|
|
WHAT IS THE RELIEF SET AT ON THE AUXILIARY PUMP?
|
112 PSI
|
|
WHAT IS THE TRANSFER PUMP RATED AT?
|
200/300 gpm at 50 psi
|
|
WHAT IS THE RELIEF SET AT ON THE TRANSFER PUMP?
|
62 1/2 PSI
|
|
HOW MANY BALL BEARINGS LOCATED AND HOW MANY?
|
TWO BEARINGS LOCATED IN EACH HEAD ASSEMBLY
|
|
WHAT IS THE CLEARANCE SET AT ON THE BALL BEARINGS?
|
0.0125 MM
|
|
WHERE DOES THE PRESSURE RELIEF GO BACK TO WHEN IT RELIEVES TOO MUCH PRESSURE?
|
SUCTION SIDE OF THE PUMP
|
|
HOW ARE THE SLIDING VANES KEPT IN CONTACT WITH THE CYCLINDER BORE?
|
BY CENTRIFUGAL FORCE AND PUSHRODS
|
|
ON THE STRIPPING PUMP IT SHOULD NOT BE RUN DRY FOR LONGER THAN HOW MANY MINTUES?
|
2 MINUTES
|
|
WHAT IS THE HORSEPOWER ON THE STRIPPING PUMP?
|
5 HORSEPOWER
|
|
WHAT ARE THE POWER REQUIREMENTS FOR THE STRIPPING PUMP(VOLATAGES)?
|
440V/60HZ/3 PHASE
|
|
WHAT IS THE GEAR RATIO FOR THE STRIPPING PUMP?
|
3.32:1
|
|
HOW LONG SHOULD YOU OBSERVE LEAKAGE FROM THE TELL-TALE HOLE?
|
30 MINUTES
|
|
RELIEFS SHOULD LIMIT PUMP FROM EXCEEDING WHAT %?
|
125%
|
|
BEARINGS ON THE STRIPPING PUMP SHOULD BE REPLACED WHEN RADIAL PLAY REACHES WHAT AMOUNT?
|
.005 INCHES
|
|
WHEN TIGHTENING LOCK NUTS ON THE STRIPPING PUMP HOW MANY FT LBS OF TORQUE ARE REQUIRED?
|
20 PLUS OR MINUS 5
|
|
WHAT IS THE MAX HORSEPOWER ON THE TRANSFER PUMP?
|
25 HORSEPOWER
|
|
WHAT IS THE SUCTION LIFT ON THE TRANSFER PUMP?
|
15 HG
|
|
ON THE TRANSFER PUMP HOW LONG AND AT WHAT TEMPERATURE SHOULD YOU HEAT UP THE BALL BEARINGS?
|
1 HOUR AT 250 DEGREES
|
|
TRANSFER BEARING LOCKNUT SHOULD BE TORQUED TO WHAT FT LBS?
|
10-20 FT LBS
|
|
YOU SHOULD NOT FILL UP THE GREASE PAST WHAT PERCENT?
|
50%
|
|
ON THE STRIPPING PUMP THE OIL IN THE RREDUCTION GEAR SHOULD NTO HEAT PAST WHAT DEGREES?
|
180 DEGREES
|
|
TELLTALE HOLES SHOULD NOT EXCEED HOW MANY DROPS PER DAY? |
3 DROPS PER DAY |
|
THE TRANSFER PUMP SHOULD REACH HOW MANY PSI WITHIN HOW MANY MINUTES BEFORE CONSIDERED RUNNING DRY? |
15 PSI WITHIN 2 MINUTES |
|
WHAT IS THE CLEARANCE OF THE ROTOR TO THE CYLINDER BORE? |
.002 TO .008 INCHES |
|
What do the flexible couplings serve as? |
Allow for slight misalignment between pump,gear reducer and motor shaft. |
|
How is the pressure regulated? |
Pressure control valve |
|
The defuel pump has a disc that is how many inches to allow what percent of fuel flow back to the suction header? |
The disc in the valve has a 5/32 inchdrilled hole to allow 5 percent flow to thedefuel pump suction header when theservice system is in operation.
|
|
During inspection of the rotor and shaftassembly you notice that the shaft is bent, whatrepair action should you take? |
Change the shaft |
|
What are the four major components of theRotary Vane Pumps?
|
Cylinder, Head, Pressure ControlValve, and the Rotor and Shaft Assembly
|
|
How is the rotor held to the shaft?
|
Keys and pins |