• Shuffle
    Toggle On
    Toggle Off
  • Alphabetize
    Toggle On
    Toggle Off
  • Front First
    Toggle On
    Toggle Off
  • Both Sides
    Toggle On
    Toggle Off
  • Read
    Toggle On
    Toggle Off
Reading...
Front

Card Range To Study

through

image

Play button

image

Play button

image

Progress

1/33

Click to flip

Use LEFT and RIGHT arrow keys to navigate between flashcards;

Use UP and DOWN arrow keys to flip the card;

H to show hint;

A reads text to speech;

33 Cards in this Set

  • Front
  • Back
SYSTEMS RELY ON THE BLEED AIR SYSTEM
AIR CONDITIONING / PRESSURIZATION
WING AND ENGINE TERMAL ANTI-ICING
ENGINE STARTING
HYDRAULIC RESERVOIR PRESS
WATER TANK PRESS
APU IS CAPABLE OF SUPPLYING BLEED AIR...
TWO PACKS ON THE GROUND
ONE PACK IN FLIGHT
DO NOT OPERATE MORE THAN ONE PACK
FROM ONE ENGINE
WING BODY OVERHEAT TEST
HOLD FOR A MINIMUM 5 SECONDS
BOTH WING BODY OVERHEAT LIGHTS ILLUMINATED
MASTER CAUTION LIGHT ILLUMINATED
AIR COND SYSTEM ANUNCIATOR ILLUMINATED
BLEED TRIP OFF
ILLUMINATED AMBER
EXCESSIVE ENGINE BLEED AIR TEMP OR PRESS
MASTER CAUTION
AIR CONDITION
TRIP RESET SWITCH
RESETS:
BLEED TRIP OFF
PACK
ZONE TEMP LIGHT
TRIP RESET SWITCH OPENS
ENGINE BLEED VALVE
PACK VALVE
MIX VALVE
RECIRCULATION FAN SWITCHES
12
2A
THE PACK TEMPERATURE CONTROL VALVE
CONTROLS THE QUANTITIY OF WARM AIR THAT IS MIXED WITH THE COOL AIR DOWNSTREAM OF THE AIR CYCLE MACHINE
WITH THE PACK TEMPERATURE CONTROL VALVE
THE PACK SUPLIES AIR AT THE TEMPERATURE OF THE ZONE WITH THE LOWEST SET TEMPERATURE
PACK HIGH FLOW AUTOMATIC SWITCHING IS INHIBITED WHEN
THE AIRPLANE IS ON THE GROUND OR
IN FLIGHT WITH THE FLAPS EXTENDED
AUTOMATIC SWITCHING TO HIGH AIR FLOW OCCURS
BOTH ENGINE BLEED AIR SITCHES ARE OFF
APU BLEED SWITCHES ARE ON
REGARDLESS OF FLAP POSITION
AIR / GROUND STATUS
NUMBER OF PACK OPERATING
MAXIMUM AIRFLOW WHEN THE APU IS THE ONLY SOURCE OF BLEED AIR
ON THE GROUND
APU BLEED AIR SWITCH IS ON
EITHER OR BOTH PACK SWITCHES ARE POSITION TO HIGH
IF A PRIMARY PACK CONTROL FAILS
THE AFFECTED PACK IS CONTROLLED BY THE STANDBY PACK CONTROL IN THE OPPOSITE CONTROLLER
A PRIMARY OR STANDBY PACK CONTROL FAILURE CAUSES
PACK
MASTER CAUTION
AIR CONDITION
IF BOTH PRIMARY AND THE STANDBY PACK CONTROLS FAIL FOR THE SAME PACK
THE PACK CONTINUE TO OPERATE WITHOUT CONTROL UNLESS EXCESSIVE TEMPERATURE CAUSE THE PACK TRIP OFF
THE TEMPERATURE SELECTOR RANGE
18 C - 30 C
THE RIGHT PACK CONTROLLER
PRIMARY CONTROLLER FOR THE FLIGHT DECK TRIM AIR VALVE AND THE LEFT PACK CONTROLLER IS THE SECONDARY CONTROLLER
BECAUSE THE PACKS SUPPLY AIR AT THE TEMPERATURE OF THE COLDEST ZONE
THAT ZONE DOES NOT NEED TRIM AIR AND RELATED TRIM AIR VALVE CLOSED
THE OVERBOARD EXHAUST VALVE IS DRIVEN OPEN
IF EITHER PACK SWITCH IS IN HIGH OR THE RIGHT CIRCULATION FAN IS OFF
ZONE TEMP
CONT CABIN
INDICATES A DUCT TEMPERATURE OVERHEAT OR FAILURE OF THE FLIGHT DECK PRIMARY AND STANDBY TEMPERATURE CONTROL
ZONE TEMP
FWD CABIN AFT CABIN
INDICATES DUCT TEMPERATURE OVERHEAT
ZONE TEMP
CONT CABIN
MASTER CAUTION RECALL
INDICATES FAILURE OF THE FLIGHT DECK PRIMARY OR STANDBY TEMPERATURE CONTROL
ZONE TEMP
FWD CABIN AFT CABIN
MASTER CAUTION RECALL
INDICATES FAILURE OF THE ASSOCIATED ZONE TEMPERATURE CONTROL
WHEN THE TRIM AIR SWITCH IS OFF
THE PACKS OPERATES INDEPENDENTLY
LEFT PACK FLIGHT DECK
RIGHT PACK AVERAGE OFF FWD AND AFT CABIN
CABIN PRESSURE CONTROLLER
8000 FEET AT THE AIRPLANE MAXIMUM CERTFIED CEILING OF 41000 FEET
DURING T/O ROLL
THE CABIN PRESSURIZES TO AN ALTITUDE OF 200 FEET BELOW THE AIRPORT ELEVATION
WHEN THE AIRPLANE DESCENDS FROM CRUISE ALTITUDE
CABIN ALTITUDE DESCEND TO 300 FEET BELOW THE PLANNED LANDING ELEVATION
AUTO FAIL LIGHT
LOSS OF DC POWER
CONTROLLER FAULT
OUTFLOW VALVE CONTROL FAULT
EXCESSIVE DIFFERANTIAL PRESSURE
EXCESSIVE RATE OF CABIN PRESSURE CHANGE
HIGH CABIN ALTITUDE
SYSTEM SAFETY RELIEF DIFFERANTIAL PRESSURE
9.10 PSI
MAXIMUM ALOWABLE CABIN PRESSURE DIFFERANTIAL FOR T/O AND LANDING
0.125 PSI
DURING SINGLE PACK OPERATION WITH TRIM AIR SELECTED OFF
THE PACK ATTEMPTS TO PRODUCE AN AIR TEMPERATURE TO SATISFY THE AVERAGE TEMPERATURE OF ALL THREE ZONES
IF ALL TEMPERATURE SELECTORS ARE POSITIONED TO OFF
LEFT PACK MAINTAIN FIXED 24 C
RIGHT PACK MAINTAIN FIXED 18 C