whats the overall length of the vehicle from front bumper to back of platform

47 feet 1 inch

what is the calculated weight including mfg mounted equipment, personnel, hose and a full tank of water

69,119 lbs

what is the rated vertical reach of the truck


(Height)

100 feet

what is the rated horizontal reach of the truck

88.5 feet

what type of transmission does the truck have?

Allison

what type of engine does the truck have?


HP and Type

500 hp Cummins Diesel Engine

what is the normal engine oil pressure range?

25-65 psi

a steady reading of _____ - ______ amps is normal

0-25 amps

voltmeter indicates battery condition showing _________-_________ being normal

13-14.5

the engine will lose power if voltage drops below ___________ VDC for any period of time

10 VDC

what is the normal operating air pressure range?

110 - 125 psi

the engine coolant should not reach _______. degrees F.




the max allowable temp is ___________ degrees F

200 degrees F




Max - 250 degrees F

what should you do if the temp exceeds the max temp?

bring the truck to an idle until cooled off

where are the chock blocks to be placed on the truck?




what about during aerial operations?

front driver side tire




-Both front tires during aerial operations

what is the overall height of the apparatus?

11 feet 7 inches tall

what is the maximum operating angle of the aerial devise when fully extended?

80 degrees

what is the tip load rating with NO water flowing?

1,000 lbs at any angle, elevation or extension

what is the tip load rating WITH water flowing?

500 lbs at any angle, elevation, or extension

the low air alarm sound if the breathing air lines are bleeding down. where is the indicator light?

on the turn table platform

what should you do if the automatic fast idle activate and the need arise to engage the fire pump?

the fast idle can only be deactivated by MOMENTARILY DISENGAGING THE PARKING BRAKE.

the truck is equipped with what kind of a pump

Hale 2 stage 1750 gpm midship pump

if the hydraulic generator is operated above _________ degrees for an extended period of time, the oil can rapidly oxidize and deteriorate causing generator performance problems

150 degrees

the recommended oil level that is to be maintained is how full?

1/2 - 3/4 full

the engine in the truck uses what kind of oil and how much?



41.2 quarts of 15W 40

fuel capacity of the truck

65 gallons of diesel

Dexron III is used for what?

the generator lubricant,


leveling system,


aerial tower fluid,


cab-tilt fluid


power steering fluid

________________ is used for the generator lubricant, leveling system, aerial tower fluid, cab-tilt fluid and power steering fluid

Dexron III

the Allison transmission gives the operator the ability of checking the transmission fluid from the push button shift selector. several conditions must be satisfied to accurately use this feature including:

-the fluid temperature is between 140 degrees F - 220 degrees F


-transmission is in neutral


-vehicle has been stationary for approximately 2 minutes to allow fluid to settle

Sutphen recommends that for maximum vertical coverage, the apparatus should be spotted about _____________ feet from the building when possible

30 - 35 feet

what is the platform weight capacity

1,000 lbs

what is the weight capacity when the water way is filled with water?

500 lbs

is Rappelling from the ladder truck permitted?

no, it is not permitted at any point

The aerial can be used in winds up to _______mph

50 mph

Any one working from the bucket must wear/use a ______________

ladder belt

spot the outriggers __________- feet from the building if possible

30 - 35 feet

what is the stokes arm max capacity?

250 lbs

when working from the bucket and in close proximity to an object, the ___________ must be used to give the operator more exact control of the bucket movement

low range switch

this apparatus is designed to work in "out of level" conditions up to _________ degrees side to side and ____________ degrees front to rear

5 degrees side to side




20 degrees front to rear

what is designed to be the ground point for the apparatus.

the rear jacks

can you use jack pads on the rear jacks and why or why not?

no




the rear jacks are designed to be the grounding point for the apparatus, therefore, if jack pads are ever used, they should be metal type only

what are the specifics regarding outrigger safety pin placement

when preparing to insert the outriger safety pins, if the safety pin hole is near 1/2" or less to the safety bar, go to the next higher hole.




this will avoid having the pin pinched by cylinder creep that will later not allow you to remove the pin when taking down the truck.

what are the specifics regarding raising the boom during hose loading operations



interlock override buttons...

if raising the boom during hose loading operations, the rear jacks must be set to provide stability and the interlock override buttons on top of the pedastal must be used. when the ladder is lowered back into the bed the interlock override buttons must be pressed again, to completely bed the ladder


-Raise to 30 degrees


-rear jacks needed only.

what should be done prior to retracting the aerial after the waterway has been used?

open the turrets and waterway drains to prevent serious damage to the waterway

true or false?




when the fire pump is engaged, the "high speed" switch is enabled?

false




it is disabled!

when the tank fill / pump recirculator is used, a large amount of water will dump onto the _______________ if not monitored

generator

how do you silence the jack warning alarm once the placement of the jacks is complete?

insert the pins!

if operating near power lines, what precautions can the operator take?

stand on the operator's step at all times during tower operations.

the tower can be elevated from ________- degrees to _________ degrees from horizontal while in any position of extension

minus 5 degrees




plus 80 degrees


if the boom is lowered toward the body or outriggers, what alarm will activate?

smart boom warning system

tell me more about the smart boom warning system

the controls will go into creep mode and visual and audible alarms will sound.

how do you cancel the smart boom warning system alarm, and where is it cancelled?

the silence alarm button will only cancel the alarm at the operators station




once the boom is raised out of the contact zone, the alarms and full operational speed will be reset automatically

smart boom warning system




what point are the alarms and full operational speed reset?

once the boom is raised out of the contact zone, the alarms and full operational speed will be reset automatically

where should there be an operator any time the aerial is in use?

at the lower control station

the platform controls always override the lower controls




true/false

false




the lower controls can always override the platform controls if an emergency arise

the apparatus is equipped with a ________- gallon water tank

300 gallon

leveling system override details

the leveling system override is a one needle valve located on the left side of the platform wall. open the valve 1/4 of a turn and the hydraulic cylinder will operate with the weight in the platform, thus keeping the platform level.

the breathinig air system should be regulated where and set to what pressure

should be regulated at the supply cylinder by presetting the regulator at approximately 120 psi

what is the proper procedure to place the aerial into operation


(1 of 2)

-spot the apparatus


-set brake


-place transmission in neutral


-ensure engine is at low idle


-engage aerial PTO


-verify truck is in level operating range (green)


-verify fluid transfer valve is in the ground jack position


-extend left outrigger to maximum extension


-extend right outrigger to max extension

what is the proper procedure to place the aerial into operation


(2 of 2)

-place ground pads under each outrigger foot


-lower left outrigger until it reaches ground pad


-lower right outrigger until it reaches ground pad


-level truck from side to side


-pull both left and right outrigger down levers simultaneously and raise the front of the truck until the front tires clear the ground


-lower rear jacks until tires on front tandem just clear the ground


-pull front jack handle to engage front stabilizer


-insert safety pins in outriggers


DONE!