General craft fire |
-Bring craft to hullborne condition - Announce fire call away fire party muster troops on cargo deck as appropriate - Pull fire door and fuel shutoff valve manual pull handles -turn off main engines auxiliary fan -Man nozzle fixed halon 1211 system and proceed to scene -man fixed halon 1211 system and stand by to charge hose -fire party approach fire area avoiding exposure to toxic smoke and fumes from affected compartment - to maintain halon concentration inject halon 1211 via fire inject or view ports into engine of APU compartment within 3 minutes of halon 1301 discharge using 5 second burst every 3 minutes for 15 minutes -Isolate fire area electrically -Navigator relieve loadmaster Rig utility pump -Inform operational commander control unit and other craft in company on a regular basis concerning the status of the emergency |
|
Over temp M/E |
-Turn on engine compartment auxiliary cooling fan -if display goes out in ten(10) seconds, proceed on assignment - if Compt overtemp frame remains on after (10) seconds reduce N1 on affected engine; increase N2 an prop pitch on unaffected side - if display goes out in ten(10)seconds proceed on assignment -If display remains on after ten (10) seconds reduce N2 and prop pitch on affected side, secure affected - If compt overtemp frame remains on after ten (10) seconds, stop craft, go hullborne, and investigate conditions -Proceed to compartment fire if fire in present - discharge primary (A) Halon bottle -Acknowledge Alarm -if fire light goes out and mission requirements allow, man firefighting team in accordance with general craft fire procedures (paragraph 3-2.5) -if fire light remains on for 18 seconds discharge (b) bottle -if fire light goes out man firefighting team in accordance with general craft fire procedures(paragraph3-2.5) If fire light still remains on shut down adjacent engine and/or APU -Shut down fuel supply to affected components by use of manual firewall shutoff valve - man firefighting team in accordance with general craft fire procedures (paragraph 3-2.5) |
|
Fire fuel bays |
-Discharge primary (a) halon bottle -acknowledge alarm - shut down fuel transfer system -shutdown affected main engines and APU -Shut down fuel pumps for affected fuel bay - If fire light goes out and mission requirements allow, man firefighting team in accordance with general craft fire procedures(paragraph 3-2.5) -If firelight remains on for 15 seconds discharge (b) bottle, stop craft, go hullborne - shut down remaining main engines and APU -shut down remaining fuel system -man firefighting team in accordance with general craft fire procedures (paragraph 3-2.5) |