term1 Definition1term2 Definition2term3 Definition3
Please sign in to your Google account to access your documents:
General craft fire
-Bring craft to hullborne condition
- Announce fire call away fire party muster troops on cargo deck as appropriate
- Pull fire door and fuel shutoff valve manual pull handles
-turn off main engines auxiliary fan
-Man nozzle fixed halon 1211 system and proceed to scene
-man fixed halon 1211 system and stand by to charge hose
-fire party approach fire area avoiding exposure to toxic smoke and fumes from affected compartment
- to maintain halon concentration inject halon 1211 via fire inject or view ports into engine of APU compartment within 3 minutes of halon 1301 discharge using 5 second burst every 3 minutes for 15 minutes
-Isolate fire area electrically
-Navigator relieve loadmaster
Rig utility pump
-Inform operational commander control unit and other craft in company on a regular basis concerning the status of the emergency
Over temp M/E
-Turn on engine compartment auxiliary cooling fan
-if display goes out in ten(10) seconds, proceed on assignment
- if Compt overtemp frame remains on after (10) seconds reduce N1 on affected engine; increase N2 an prop pitch on unaffected side
- if display goes out in ten(10)seconds proceed on assignment
-If display remains on after ten (10) seconds reduce N2 and prop pitch on affected side, secure affected
- If compt overtemp frame remains on after ten (10) seconds, stop craft, go hullborne, and investigate conditions
-Proceed to compartment fire if fire in present
- discharge primary (A) Halon bottle
-Acknowledge Alarm
-if fire light goes out and mission requirements allow, man firefighting team in accordance with general craft fire procedures (paragraph 3-2.5)
-if fire light remains on for 18 seconds discharge (b) bottle
-if fire light goes out man firefighting team in accordance with general craft fire procedures(paragraph3-2.5)
If fire light still remains on shut down adjacent engine and/or APU
-Shut down fuel supply to affected components by use of manual firewall shutoff valve
- man firefighting team in accordance with general craft fire procedures (paragraph 3-2.5)
Fire fuel bays
-Discharge primary (a) halon bottle
-acknowledge alarm
- shut down fuel transfer system
-shutdown affected main engines and APU
-Shut down fuel pumps for affected fuel bay
- If fire light goes out and mission requirements allow, man firefighting team in accordance with general craft fire procedures(paragraph 3-2.5)
-If firelight remains on for 15 seconds discharge (b) bottle, stop craft, go hullborne
- shut down remaining main engines and APU
-shut down remaining fuel system
-man firefighting team in accordance with general craft fire procedures (paragraph 3-2.5)