Misalignment of the tube-part-IR relationship results in

Shape distortion

In digital imaging, brightness is controlled by:


-IR exposure


-monitor functions


-post processing functions

Monitor functions and post processing functions

An electronic Imaging, as Digital Image Matrix size increases:


-Pixel size decreases


-resolution decreases


-pixel depth decreases

Pixel size decreases

An algorithm, as used in x-ray Imaging is a

Series of variable instructions

The chest radiograph shown in figure 4-1 demonstrates

Aliasing artifact

The intensity of ionizing radiation decreases as

Distance from the source of radiation increases

Grid interspace material can be made of


-carbon fiber


-aluminum


-plastic fiber

-Aluminum


-plastic fiber

The reduction in x-ray Photon intensity as the photon passes through material is termed

Attenuation

Which of the lines indicated represents the dynamic range offered by computed radiography / digital radiography?

Line A is representative of CR /DR

An increase in kilovoltage will have which of the following effects and digital imaging?


-More scattered radiation will be produced


-the exposure rate will increase


-radiographic contrast will increase

-More scattered radiation will be produced


-the exposure rate will increase

The X-ray tube used in CT must be capable of


-high-speed rotation


-short pulsed exposures


-withstanding millions of heat units

All

What is the correct critique of the CR image shown

Double exposure

If a lateral projection of the chest is being performed on an aesthetic patients and outer photocells are selected, what is likely to be the outcome?

Decreased IR exposure

Which of the following groups of exposure factors will produce the greatest receptor exposure?

400 mA, 70 ms

The component of a CR image plate (IP) that records the radiologic image is the

Photostimulable phosphor

An x-ray image of the ankle was made at 40 SID, 200 mA, 50 ms, 70 kV, 0.6 mm focal spot, and minimal OID. Which of the following modifications would result in greatest increase in magnification?

4-in OID

The radiation dose received by the digital detector for each image is indicated by the

Exposure indicator

HVL is affected by the amount of


-kVp


-Beam filtration


-tissue density

Kvp


beam filtration

The luminescent light emitted by the PSP is transformed into the image seen on the CRT by the

ADC

The lateral coccyx image shown was made using AEC but is over exposed. This is most likely a result of

Incorrect centering of the part

Which of the following units is used to express resolution?


-Line spread function


-line pairs per millimeter


-line Focus principle

Line spread function


line pairs per millimeter

The term windowing describes the practice of

Changing the image brightness and/or contrast scale

Foreshortening can be caused by

The radiographic object being placed at an angle to the IR

Acceptable method(s) of minimizing motion unsharpness is (are)


-suspended respiration


-short exposure time


-patient instruction

All

Using fixed milliampere seconds and variable kilovoltage technical factors, each centimeter increase and patient thickness requires what adjustment in kilovoltage?

Increase 2 kV

Unopened boxes of radiographic film should be stored away from radiation and

In the vertical position

Potential Digital Image post-processing tasks include


-PACS


-annotation


-inversion/reversal

Annotation


inversion/reversal

Factors that contribute to film fog include


-the age of the film


-excessive exposure to safelite


-processor chemistry

All

X-ray Photon energy is inversely related to


-photo wavelength


-applied milliamperes


-applied kilovoltage

Photon wavelength

Which of the radiographs is shown most likely required the greater exposure?

Image b

Characteristics of DR imaging include:


-solid-state detector receptor plates


-a direct-capture imaging system


-immediate image display


All

Compared with a low-ratio grid, a high-ratio grid will


-allow more centering latitude


-absorb more scattered radiation


-absorb more primary radiation


-absorb more scattered radiation


-absorb more primary radiation


A decrease in kilovoltage will result in:


-a decrease in image resolution


-a decrease in photon energy


-a decrease in receptor exposure


-a decrease in photon energy


-a decrease in receptor exposure


What is the correct critique of the CR image shown

inverted IP

To be suitable for use in an image intensifiers input screen, a phosphor should have which of the following characteristics?


-high conversion efficiency


-high x-ray absorption


-high atomic number


all

Resolution in CR increases as:


-laser beam size decreases


-monitor matrix size decreases


-PSP crystal size decreases


-laser beam size decreases


-PSP crystal size decreases

What pixel size has a 512 x 512 matrix with a 20-cm field of view (FOV)?

0.40 mm/pixel

In radiography of a large abdomen, which of the following is (are) effective way(s) to minimize the amount of scattered radiation reaching the image receptor (IR)?


-use of close collimation


-use of low mAs


-use of a low-ratio grid


use of a close collimation