Misalignment of the tube-part-IR relationship results in |
Shape distortion |
|
In digital imaging, brightness is controlled by: -IR exposure -monitor functions -post processing functions |
Monitor functions and post processing functions |
|
An electronic Imaging, as Digital Image Matrix size increases: -Pixel size decreases -resolution decreases -pixel depth decreases |
Pixel size decreases |
|
An algorithm, as used in x-ray Imaging is a |
Series of variable instructions |
|
The chest radiograph shown in figure 4-1 demonstrates |
Aliasing artifact |
|
The intensity of ionizing radiation decreases as |
Distance from the source of radiation increases |
|
Grid interspace material can be made of -carbon fiber -aluminum -plastic fiber |
-Aluminum -plastic fiber |
|
The reduction in x-ray Photon intensity as the photon passes through material is termed |
Attenuation |
|
Which of the lines indicated represents the dynamic range offered by computed radiography / digital radiography? |
Line A is representative of CR /DR |
|
An increase in kilovoltage will have which of the following effects and digital imaging? -More scattered radiation will be produced -the exposure rate will increase -radiographic contrast will increase |
-More scattered radiation will be produced -the exposure rate will increase |
|
The X-ray tube used in CT must be capable of -high-speed rotation -short pulsed exposures -withstanding millions of heat units |
All |
|
What is the correct critique of the CR image shown |
Double exposure |
|
If a lateral projection of the chest is being performed on an aesthetic patients and outer photocells are selected, what is likely to be the outcome? |
Decreased IR exposure |
|
Which of the following groups of exposure factors will produce the greatest receptor exposure? |
400 mA, 70 ms |
|
The component of a CR image plate (IP) that records the radiologic image is the |
Photostimulable phosphor |
|
An x-ray image of the ankle was made at 40 SID, 200 mA, 50 ms, 70 kV, 0.6 mm focal spot, and minimal OID. Which of the following modifications would result in greatest increase in magnification? |
4-in OID |
|
The radiation dose received by the digital detector for each image is indicated by the |
Exposure indicator |
|
HVL is affected by the amount of -kVp -Beam filtration -tissue density |
Kvp beam filtration |
|
The luminescent light emitted by the PSP is transformed into the image seen on the CRT by the |
ADC |
|
The lateral coccyx image shown was made using AEC but is over exposed. This is most likely a result of |
Incorrect centering of the part |
|
Which of the following units is used to express resolution? -Line spread function -line pairs per millimeter -line Focus principle |
Line spread function line pairs per millimeter |
|
The term windowing describes the practice of |
Changing the image brightness and/or contrast scale |
|
Foreshortening can be caused by |
The radiographic object being placed at an angle to the IR |
|
Acceptable method(s) of minimizing motion unsharpness is (are) -suspended respiration -short exposure time -patient instruction |
All |
|
Using fixed milliampere seconds and variable kilovoltage technical factors, each centimeter increase and patient thickness requires what adjustment in kilovoltage? |
Increase 2 kV |
|
Unopened boxes of radiographic film should be stored away from radiation and |
In the vertical position |
|
Potential Digital Image post-processing tasks include -PACS -annotation -inversion/reversal |
Annotation inversion/reversal |
|
Factors that contribute to film fog include -the age of the film -excessive exposure to safelite -processor chemistry |
All |
|
X-ray Photon energy is inversely related to -photo wavelength -applied milliamperes -applied kilovoltage |
Photon wavelength |
|
Which of the radiographs is shown most likely required the greater exposure? |
Image b |
|
Characteristics of DR imaging include: -solid-state detector receptor plates -a direct-capture imaging system -immediate image display |
All |
|
Compared with a low-ratio grid, a high-ratio grid will -allow more centering latitude -absorb more scattered radiation -absorb more primary radiation |
-absorb more primary radiation |
|
-a decrease in image resolution -a decrease in photon energy -a decrease in receptor exposure |
-a decrease in receptor exposure |
|
What is the correct critique of the CR image shown |
inverted IP |
|
To be suitable for use in an image intensifiers input screen, a phosphor should have which of the following characteristics? -high conversion efficiency -high x-ray absorption -high atomic number |
all |
|
Resolution in CR increases as: -laser beam size decreases -monitor matrix size decreases -PSP crystal size decreases |
-PSP crystal size decreases |
|
What pixel size has a 512 x 512 matrix with a 20-cm field of view (FOV)?
|
0.40 mm/pixel |
|
In radiography of a large abdomen, which of the following is (are) effective way(s) to minimize the amount of scattered radiation reaching the image receptor (IR)? -use of close collimation -use of low mAs -use of a low-ratio grid |
use of a close collimation |