What factors influence the layout of a commercial kitchen?


A) The number of seats in the dining area


B) The quantity of food to be prepared by chef Ramsay


C) The hours of operation, different types of menu, number of meals prepared per day


D) The hours of operation, menu types, number of meals prepared per day and food storage needs based on expected deliveries

D)

What the purpose of an equipment plan?


A) Allows for any tolerances needed when trying to set the pieces of equipment


B) Give the plumber an exact detailed layout of the equipment selected


C) Show all the mechanical services required for the safe operation of equipment


D) Used only to locate large equipment within the kitchen

B)

Where would you find a detailed specification for a specific piece of equipment in a commercial kitchen?


A) This information is only available to the GC and is not for reference on site


B) A detailed specification for each piece of equipment can be found in the mechanical plan on the prints


C) A detailed specification for each piece of equipment, indicating description, standard specification and optional accessories will be submitted by the equipment vendor or manufacturer


D) It can be found in the prints under architectural

C)

How important are the rough in dimensions?


A) There are very broad tolerances for all rough in dimensions


B) The walls are always laid out after the plumbing is roughed in and the rough in dimensions are met at that time


C) Allowances are made from the conversion of metric to imperial, so rough in dimensions allow for this


D) Requirements for rough in dimensions are very specific and must be followed exactly

D)

How many barrier free toilets are required in a public washroom that has 5 stalls ?


A) 1


B) 2


C) 3


D) None

A) 1

How many accessible toilets are required in a public washroom with more than 5 stalls?


A) 1


B) 2


C) 3


D) all of the above

B) 2

What’s the internal clear turning space of a barrier free toilet stall?


A) 1500mm x 1500mm


B) 1600mm x 1600mm


C) 1700mm x 1700mm


D) 2000mm x 2000mm

C)

What’s the maximum height of a control valve in a barrier free accessible shower stall?


A) 900 mm


B) 1000mm


C) 1100mm


D) 1200mm

B)

What does the NBC require for clear turning space in a barrier free toilet stall?


A) 1200mm x 1200mm


B) 1300mm x 1300mm


C) 1400mm x 1400mm


D) 1500mm x 1500mm

D)