Lead acid batteries provide how many volts/amp hours?
24V
25 or 28 Amp hours
Max continuous generator load
300
How can a generator be manually disconnected from its PS bus?
Select generator switch to TRIP
How can the battery charge rate be monitored?
Press the ammeter BATT button
What does the 0-40 button do on the ammeter?
Changes the scale from 0-400 to 0-40
Where is the GPU receptacle located?
Right rear fuselage
What does initial selection of the BATT switch to on do?
Closes both emergency contactors to to connect both batteries to the PE bus
How can you tell if the batteries are being charged by the GPU?
Charge rate will be displayed by pressing AMP BATT
Should the battery capacities be checked prior to using a GPU?
Yes
After starting both engines using a GPU, you should..
START PWR.....OFF
EXT POWER....OFF
GPU................DISCONNECT
Batteries........Check charging
After a GPU start, the GEN FAIL light will extinguish when..
Generator is online and the EXT POWER switch is selected off
When using a GPU, the bus bar system is energized when...
EXT POWER switch is selected on
Max battery charge rate before takeoff
20
What are the transient generator load limits?
Up to 400 for 2 minutes
Max discrepancy between generator ammeter readings?
40
Purpose of the standby inverter
Power the XE bus if XS1 loses power
Sources for battery charging
Engine generators
APU generator
GPU
Which battery normally closes both emergency conatactors?
Batt 1
What does the BATT EMERG switch do?
BATT 1 and 2 close emergency contactors and both battery contactors are opened
What does the battery isolate switch do?
Isolates either Batt 1 OR 2 from its charging source
GPU requirements?
28V
1500 amps
1100 amps limiter
When charging batteries using a GPU, when should the EXT BATT CHG be turned off?
Current drops below 5 amps
Inverters provide what kind of power?
115V AC
APU generator provides?
28V DC
What does the APU generator initially power?
PS2
PE
PE2
Charges Batt 2
What switch must be turned on after APU generator is online?
BUS TIE CLOSE
What does bus bar protection provide?
Opens both battery contactors if voltage is above 29.5 or below 24.5
#1 Inverter powers
XE and XS1
#2 Inverter powers
XS2
What is the purpose of the bus tie?
Ties PS1 to PS2, or separates PS1 from PS2
How long can the batteries power the capatain's instruments after a dual generator failure?
60 minutes