3-99Q1

Compliance with MPE, or Maximum Permissible Exposure to RF levels (as defined in FCC Part 1, OET Bulletin 65) for “controlled” environments, are averaged over _______ minutes, while “uncontrolled” RF environments are averaged over ______ minutes.
6, 30
3-99Q2

Sites having multiple transmitting antennas must include antennas with more than _______% of the maximum permissible power density exposure limit when evaluating RF site exposure.
5
3-99Q3

RF exposure from portable radio transceivers may be harmful to the eyes because:
RF heating may cause cataracts
3-99Q4

At what aggregate power level is an MPE (Maximum Permissible Exposure) study required?
1000 Watts ERP
3-99Q5

Why must you never look directly into a fiber optic cable?
An active fiber signal may burn the retina and infra-red light cannot be seen
3-99Q6

If the MPE (Maximum Permissible Exposure) power is present, how often must the personnel accessing the affected area be trained and certified?
Yearly
3-100Q1

What device can protect a transmitting station from a direct lightning hit?
There is no device to protect a station from a direct hit from lightning
3-100Q2

What is the purpose of not putting sharp corners on the ground leads within a building?
Lightning will jump off of the ground lead because it is not able to make sharp bends
3-100Q3

Should you use a power drill without eye protection?
No
3-100Q4

What class of fire is one that is caused by an electrical short circuit and what is the preferred substance used to extinguish that type of fire?
FE30
3-100Q5

Do shorted-stub lightning protectors work at all frequencies?
No, only at the tuned frequency band
3-100Q6

What is a GFI electrical socket used for?
To prevent electrical shock by sensing ground path current and shutting the circuit down