FORMAT:
First Officer Prompt: "__________" ;
Captain Reply: "__________"
FO: "First Officer"
C: "Captain"
NOTE: student may use prompts, cockpit diagrams, posters, and Quick Study Guide as references during check
EXAMPLE:
FO: "Selector Valves"
C:: "Normal"
"-" means status that must be verified
":" means action that must be taken or verified, or FO prompt to be followed by statement
"::" means action Captain must take
FO: "Flight compartment safety inspection & external walkaround"
C:: "Completed"
FO: "Pedals, seat, & harness"
C:: "Adjusted"
FO: "Selector Valves"
C:: Selector valves - up and guarded
C: "Normal"
FO: "O2 Test";

NOTE: Both P and FO perform O2 mask test without prompting each step of the test.
C:: Verify O2 Pressure (1410+) on ED2 (right of EICAS) adequate by table, need not memorize table
C:: Check Mic is operational
select "MASK" on radio panel (bottom of center console), then tap mask and listen to speakers
C:: Verify regulator flow at 100% (switch under O2 line on mask)
C:: Push "TEST/RESET" Lever, listen for airflow and look for yellow cross to verify flow. Then, squeeze mask release paddles. Release paddles then push emergency flow control (red dial at bottom of mask compartment) and verify yellow cross. Release emergency flow control and TEST/RESET Lever.
C:: "O2 mask checked at ___ PSI"
FO: "Electrics"
C:: DC service switch - OFF
BATTERY MASTER - ON
IDG Disconnects - Guarded and dark
APU GEN switch - As required
GEN 1 & 2 switches - OFF/RESET
switchlights (PBAs) - Flush, no lights (dark cockpit)
C:: "Electronics Checked"
FO: "Fire Protection" (warning portion)
C:: ED1: No FIRE FAIL messages
Loop switches (5) - BOTH
TEST switch - hold at WARN
audio - warnings
Master Warning PBA - illuminated: reset (either one)
RH... and LH ENG and APU FIRE PUSH PBAs - illuminated
Firex bottle discharge buttons - armed
ED1 Fire warnings (one for each test loop, 5) - displayed
After 10 sec delay;
Master caution PBAs - illuminated
1chime - sounds
Master caution PBAs - reset (either one)
ED1: Check for SOV caution messages (5) - displayed
TEST switch: release
All fire detection indications - removed
[Fire protection test continued on next slide]
FIRE PROTECTION TEST, CONTINUED (fail portion)
TEST switch:: select and hold FAIL
Master caution PBA - illuminated
audio - warning (1chime)
ED1 - caution messages (5) - displayed
Test switch: release
All fire detection indications - removed
[Fire protection test continued on next slide]
FIRE PROTECTION TEST, CONTINUED (Firex monitor panel)
ENGINE BOTTLE 1 & 2 switches: select and hold both
advisory messages (4) - squib cautions displayed
ENGINE BOTTLE 1 & 2 switches: release
Firex advisory messages - removed
C:: "Fire Protection Checked"
FO: "Lights"
C:: State position,
"NAV lights ON, LOGO and Wing INSP lights _____ (as required)"
FO: "Fuel"
C:: boost pumps off - L BOOST PUMP and R BOOST PUMP PBAs: OFF - INOP lights illuminated
GRAVITY XFLOW PBA: OFF - dark
XFLOW AUTO OVERRIDE panel PBAs: OFF - all dark
C:: "Fuel Checked"
FO: "Bleeds" (ducts)
C:: Bleed air ducts overheat detection system test
DUCT MON rotary switch: TEST, hold
audio - warnings
ED1 - duct warnings appear
ED2 - DUCT TEST OK
BLEED AIR panel warnings - L and R 14th STAGE PBAs - DUCT FAIL; L and R 10th STAGE PBAs - DUCT FAIL
ANTI-ICE Panel - WING TEST switchlight - DUCT FAIL
DUCT MON rotary switch: release - messages removed
BLEED AIR L and R 14th STAGE PBAs: CLOSED
BLEED AIR 14th STAGE ISOL PBA: CLOSED
BLEED AIR L and R 10th STAGE PBAs: CLOSED
C: "Bleeds set"
FO: "APU"
C:: State position
FO: "START PANEL"
C:: L-ENG-R START PBAs: OFF
IGNITION A and B PBAs: OFF
IGNITION CONT PBA: OFF
C: "Checked"
FO: "Hydraulics"
C:: EICAS: hydraulic synoptic page
AC Motor Pumps (ACMPs): 1B - ON, 3A - OFF, 3B - ON, 2B - ON (all up)
HYD synoptic page - 45% to 85% total volume, reservoir lines - green, pressure - 3000 PSI
ACMPs: 1B - AUTO, 3A - ON, 3B - AUTO, 2B - AUTO
HYD synoptic page - 3A pressure at 3000 PSI
C: cancel master caution switchlight
FO: "ELT"
C:: PASS OXY PBA - Guarded, no light
C: "ELT Armed"
FO: "Pressurization"
C:: MAN ALT - Centered
EMER DEPRESS PBA - Guarded, off, dark
PRESS CONT PBA - off, dark
MAN RATE knob: full DECR
C: "Pressurization Checked"
FO: "Air Conditioning"
C:: L PACK, R PACK PBAs - as required
RAM AIR PBA - guarded, off, dark
Temperature control MAN PBAs - off, dark
CARGO FAN switch: ON
ANTI-ICE, WING switch: OFF
ANTI-ICE, COWL LH and RH switches: OFF
C: "Air conditioning checked"
FO: "Ice Detection Test"
C:: ANTI-ICE, DET TEST switch: press in
IFF wing leading edge internal temperature < 18C - ICE caution message and ICE light on
IFF wing leading edge internal temperature > 18C - ICE advisory message on
C: "Ice detection test complete"
FO: "Windshield Heat"
C:: WSHLD LH and RH toggles: LOW
ED1 - L WSHLD HEAD, R WSHLD HEAD caution messages - removed
PROBES, LH and RH toggles: OFF
C: "Windshield and heat checked"
FO: NO ACTION (verify captain moves to MISC LTS and PASS SIGNS panels)
C:: MISC LTS: DOME LIGHT - as required, STBY COMP - as required, OVHD - as required
PASS SIGNS: NO SMOKING: ON, SEAT BLTS: OFF
C: "Miscellaneous and passenger lights checked."
FO: "Emergency Lights"
C:: EMER LTS swtich: ARMED
ED1 - EMER LTS OFF caution message removed
C: "Emergency Lights Armed"
FO: "Standby Compass"
C:: Compare standby compass heading with PFD/MFD - verify acceptable deviation
NOTE: AHRS information may be inaccurate due to ground equipment magnetic disturbance
C: "Standby Compass Checked"
FO: "Stall Test"
C:: Stall Protection System Test
STALL PTCT PUSHER switches: ON
STALL PBA: Press and release
Left shaker - active
ED2 - CONT IGNITION
Start Panel - CONT PBA ON
Right shaker - active
Stick pusher - activated
STALL PBA - flash
stall mechanisms - OFF
CONT IGNITION - off
C: "Stall test complete"
FO: "EGPWS Test" OR "Emergency Ground Proximity/Wind Sheer Test"
C:: PULL UP / GND PROX PBA: Press and release - audio warnings sound
PULL UP and GND PROX PBAs - flash
ED2 - 3 fail messages
PFD - WINDSHEAR warning and caution message
MFD - TERRAIN TEST and TERRAIN DISPLAY FAIL show test pattern
after a few seconds, all warnings removed and lights dark.
FO: "Nosewheel steering"
C:: Nosewheel steering - OFF
C: "Nosewheel steering off"
FO: "Clocks"
C:: Check correct clock time
C: "Clocks set"
FO: "EFIS Control Panels"
C:: Navigation items - as needed
Remove DH, MDA, and RA TEST from PFD
Barometer: SET to current
C: "EFIS checked"
FO: "Instrument Panels"
C:: PFD and MFD - appear normal
C: "Checked"
FO: "EICAS and Standby Instruments"
C:: ED1 and ED2 - appear normal
Standby Attitude Indicator, Compass, and Altimeter - set to current and appear normal
C: "EICAS and Standby Instruments Checked"
FO: "Upper Pedestal"
C:: MLG BAY switch: hold in OVHT position - audio warnings
ED1 - MLG BAY OVHT
MLG BAY OVHT: Release - message disappears
OVHT TEST switch: hold in WARN FAIL position - audio warnings
ED1 - MLG OVHT FAIL
OVHT TEST switch: release - message disappears
C: "Landing gear fire detection test complete"
FO: "Thrust Lever Quadrant"
C:: DISC handles - aligned with their axis
SPOILERS - AUTO
THRUST REVERSERS: LH and RH switches: ARMED
ED2 - L and R REV ARMED
EMER STOW PBAs - out and dark
FLIGHT SPOILERS handle: RETRACT
Thrust Levers: FUEL SHUT OFF
GPWS FLAP OVRD switch - NORM and guarded
FLAPS: 0 degrees
"Thrust quadrant check complete"
FO: "Avionics"
C:: Radio tuning units - no fail messages
C: "Checked"
FO: "APR Switch"
C:: APR switch - ARMED
C: "APR Armed"
FO: "Engine Speed Switches"
C:: ENGINE SPEED switches: ON
C: "Engine Speed Switches on"
FO: "Trims"
C:: AIL and RUD TRIM: check free movement in both directions (white), reset to neutral (green)
C: "Trim checked"
FO: "Yaw damper"
C:: YD1 and YD2: ENGAGE (on and lit)
ED1 and 2 and PFD 1 and 2 caution messages removed
C: "Yaw Dampers Engaged"
FO: "Source Select Panel"
C:: Source selectors (4) - all normal
C: "Source selectors normal"
FO: "Lower Pedestal"
C:: Observer ACP - set as required
Transmit Switch - INT SVC
LANDING GEAR MANUAL RELEASE handle: stowed (in)
ADG Manual Deploy Handle - stowed