Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
20 Cards in this Set
- Front
- Back
FORMAT:
First Officer Prompt: "__________" ; Captain Reply: "__________" FO: "First Officer" C: "Captain" NOTE: student may use prompts, cockpit diagrams, posters, and Quick Study Guide as references during check |
EXAMPLE:
FO: "Selector Valves" C:: "Normal" "-" means status that must be verified ":" means action that must be taken or verified, or FO prompt to be followed by statement "::" means action Captain must take |
|
FO: "Flight compartment safety inspection & external walkaround"
|
C:: "Completed"
|
|
FO: "Pedals, seat, & harness"
|
C:: "Adjusted"
|
|
FO: "Selector Valves"
|
C:: Selector valves - up and guarded
C: "Normal" |
|
FO: "Crew O2 & Mask"
|
C: Verify O2 PSI >= defined requirements in table
C: "Checked & ____ PSI," ex. "Checked & 1580 PSI for 2 crew, 1 jumpseat observer, and 4 degrees outside" NOTE: Table need not be memorized |
|
FO: "O2 Test";
NOTE: Both P and FO perform O2 mask test without prompting each step of the test. |
C:: Verify O2 Pressure (1410+) on ED2 (right of EICAS)
C:: Check Mic is operational select "MASK" on radio panel (bottom of center console), then tap mask and listen to speakers C:: Verify regulator flow at 100% (switch under O2 line on mask) C:: Push "TEST/RESET" Lever, listen for airflow and look for yellow cross to verify flow. Then, squeeze mask release paddles. Release paddles then push emergency flow control (red dial at bottom of mask compartment) and verify yellow cross. Release emergency flow control and TEST/RESET Lever. C:: "O2 mask checked at ___ PSI" |
|
FO: "Electrics"
|
C:: DC service switch - OFF
BATTERY MASTER - ON IDG Disconnects - Guarded and dark APU GEN switch - As required GEN 1 & 2 switches - OFF/RESET switchlights (PBAs) - Flush, no lights (dark cockpit) C:: "Electronics Checked" |
|
FO: "Fire Protection" (warning portion)
|
C:: ED1: No FIRE FAIL messages
Loop switches (5) - BOTH TEST switch - hold at WARN, listen for 3chime, fire bell, and "jetpipe overheat" voice Master Warning PBA - illuminated: reset (either one) RH... and LH ENG FIRE PUSH and APU FIRE PUSH PBAs - illuminated BOTTLE 1 (and 2) ARMED PUSH TO DISCH and BOTTLE ARMED PUSH TO DISCH (APU) PBAs - illuminated ED1 Fire warnings (one for each test loop, 5) L ENG FIRE, R ENG FIRE, APU FIRE, L JETPIPE OVHT, R JETPIPE OVHT - displayed After 10 sec delay; Master caution PBAs - illuminated 1chime - sounds Master caution PBAs - reset (either one) ED1: Check for one SOV caution message for each tested loop (5) - L ENG SOV OPEN, R ENG SOV OPEN, APU SOV OPEN, HYD SOV 1 OPEN, HYD SOV 2 OPEN TEST switch: release All fire detection indications - removed [Fire protection test continued on next slide] |
|
FIRE PROTECTION TEST, CONTINUED (fail portion)
|
TEST switch:: select and hold FAIL
Master caution PBA - illuminated 1chime - sounds ED1: check for one caution message for each tested loop (5) - L FIRE FAIL, R FIRE FAIL, APU FIRE Test switch: release All fire detection indications - removed [Fire protection test continued on next slide] |
|
FIRE PROTECTION TEST, CONTINUED (Firex monitor panel)
|
ENGINE BOTTLE 1 & 2 switches: select both and hold to test ED2, 4 advisory messages - L ENG SQUIB 1, L ENG SQUIB 2, R ENG SQUIB 1, R ENG SQUIB 2
ENGINE BOTTLE 1 & 2 switches: release Firex advisory messages - removed C:: "Fire Protection Checked" |
|
FO: "Lights"
|
C:: State position,
"NAV lights ON, LOGO and Wing INSP lights _____ (as required)" |
|
FO: "Fuel"
|
C:: boost pumps off - L BOOST PUMP and R BOOST PUMP PBAs: pressed out (off) - INOP lights - illuminated
GRAVITY XFLOW PBA: Pressed out (off) - dark XFLOW AUTO OVERRIDE panel PBAs: Pressed out (off) - all dark C:: "Fuel Checked" |
|
FO: "Bleeds" (ducts)
|
C:: Bleed air ducts overheat detection system test
DUCT MON rotary switch: TEST, hold - 3chime, "Bleed air duct" voice ED1 - 5 warnings (L 10th DUCT, R 10th DUCT, 14th DUCT, R 14th DUCT, ANTI-ICE DUCT) ED2 - 1 advisory message (DUCT TEST OK) BLEED AIR panel warnings - L and R 14th STAGE PBAs - DUCT FAIL; L and R 10th STAGE PBAs - DUCT FAIL ANTI-ICE Panel - WING TEST switchlight - DUCT FAIL DUCT MON rotary switch: release - messages removed C: "Bleeds set" |
|
FO: 14th stage bleeds, monitor
|
C:: BLEED AIR L and R 14th STAGE PBAs: ON (in)
BLEED AIR 14th STAGE ISOL switchlight: CLOSED (out) BLEED AIR L and R 10th STAGE PBAs: CLOSED (out) |
|
FO: "APU"
|
C:: State position
|
|
FO: "START PANEL"
|
C:: L-ENG-R START PBAs: OFF
IGNITION A and B PBAs: OFF IGNITION CONT PBA: OFF C: "Checked" |
|
FO: "Hydraulics"
|
C:: EICAS: hydraulic synoptic page
AC Motor Pumps (ACMPs): 1B - ON, 3A - OFF, 3B - ON, 2B - ON (all up) HYD synoptic page - 45% to 85% total volume, reservoir lines - green, pressure - 3000 PSI ACMPs: 1B - AUTO, 3A - ON, 3B - AUTO, 2B - AUTO HYD synoptic page - 3A pressure at 3000 PSI C: cancel master caution switchlight |
|
FO: "ELT"
|
C:: PASS OXY PBA - Guarded, no light
C: "ELT Armed" |
|
FO: "Pressurization"
|
C:: MAN ALT - Centered
EMER DEPRESS PBA - Guarded, off, dark PRESS CONT PBA - off, dark MAN RATE knob: full DECR C: "Pressurization Checked" |
|
FO: "Air Conditioning"
|
... ?
|