what are the 3 main types of delivery of bio/chem
|
bursting, spray or sabatoge
|
|
what are examples of bursting type munition
|
missiles and rockets
|
|
what is an example of aerosal type munition
|
spray tanks mounted on aircraft
|
|
how does sabatoge delivery work
|
they contaminate food and water sources
|
|
what are pathogens
|
germs that cause diseases in humans.
|
|
what are the 4 types of pathogens
|
bacteria rickettsiae virus fungi
|
|
what is the incubation period
|
the pathogens reproduction period
|
|
give example of bacteria
|
anthrax plague tularemia
|
|
what is rickettsiae
|
parasite, requires a vector
|
|
what is a virus example
|
flu small pox
|
|
what are toxins
|
like nerve agents but more incapacitating act neurologically and very rapid
anything with a toxin in the name is a toxin |
|
do chemical nerve agent antidotes have any effect on the symptoms of neurotoxins
|
no
|
|
what are the 2 categories of chemical agents?
|
chemical agents and chem compounds
|
|
why is physical state important
|
it determines how its dispersed. solids, liquids or gases, also aerosals.
|
|
what is physical action:
|
the actual effect it has on individual
|
|
what are the 7 different types of agents
|
nerve, blister, blood, choking incapacitating vomiting, and tearing
|
|
what is the most dangerous chemical casualty
|
nerve agents
|
|
what do nerve agents do
|
cause over stimulation of the body and rigid paralysis
|
|
what are the treatments of nerve agents
|
2 PAMCL, CANA
|
|
what do blister agents cause
|
inflammation blistering and destruction of skin
|
|
what are the causes of death due to blister agents
|
include infection of wounds and respitory complications.
|
|
what is the antidote for blister agents
|
none
|
|
what are choking agents
|
vapors or gases irritate and burn respitory . colorless with an odor like newly mown hay
|
|
vomiting agents are
|
cause vomit
|
|
tearing agents
|
cause tears and burn mucus membranes
|
|
what does MOPP stand for
|
mission oriented protective posture
|
|
what is mission oriented protective posture
|
prepatory measures before an attack
|
|
mopp 1
|
CBR is suspected, protective masks are fitted and issued and maintained at the battle stations
|
|
mopp 2
|
MASK is maintained in its carrier on the person
|
|
mopp 3
|
install a new filter canister, don overgarments and GQ. CMWD SYSTEMS INTERMITENTLY
|
|
MOPP 4
|
immediately don mask and secure hood over head and around mask. CMWD continuously
|
|
DFU
|
DRY FILTER UNIT
|
|
WHAT IS a dry filter unit
|
self contained portable air sampler that collects and concentrates matter in the atmosphere.
|
|
what is an HHA
|
hand held assembly, tests the dfu filters or suspect surface contaminates and gives the user an identification of the bio agent within 15 minutes
|
|
what does CAPDS stand for
|
chemical agent point detector system mk 21 mod 1
|
|
what is capds
|
installed automatic vapor sensor that detects nerve agents
|
|
how does capds work
|
it samples the air outside goes to the TBU, then to the IDU, then to the RCU IN DCC.
|
|
HOW many capds are there
|
2 one port one starboard
|
|
what is IDU
|
ionization detector unit
|
|
what is rcu
|
remote control unit located in dcc 2 of them port and starboard.
|
|
what is TBU
|
through bulkhead unit located port and starboard outside
|
|
what temperature are cells heated to in the CAPDS
|
140 F 60 C
|
|
M256A-1 KIT detects what
|
nerve blister blood
|
|
what does the m256a1 kits conatin
|
12 indiv wrapped sampler detectors, a book of 25 M8 papers, instructions
|
|
what are m256a1 kits used for
|
post attack surveys to determine when to unmask
|
|
you cannot use M8 M9 OR M256A1 KIT IF you are what
|
colorblind, under red lights
|
|
inside the indiv wrapped detectors are what
|
2 ampules filled with reagant, 3 tests spot for blister blood nerve, chemical heater for testing the blister agents, protective strips, lewisite detecting tablet, and instructions
|
|
what is the heater in m256a1 used for
|
detecting blister agents
|
|
what makes the m256a1 sailor proof
|
it has what colors each thing is supposed to turn to
|
|
what 3 blister agents are detectable by the m256a1
|
mustard h, phosgene oxime, and lewisite L
|
|
what 2 blood agents are in m256a1
|
hydrogen cyanide ac cyanide cholride ck
|
|
what 2 nerve agents are in m256a1
|
v and g
|
|
what ppe must be worn when testing with m256a1
|
gloves and cbr mask
|
|
what 2 things do you look for before using m256a1
|
make sure its not expired on the top of the case, tampered with and has m8 paper.
|
|
how long must you expose the test spots on m256a1
|
10 min
|
|
how long does m256a1 take
|
15-20 min
|
|
what color will m256a1 turn if blister agent is present
|
purple or blue for mustard, red or purple for phosgene, false positive with high temps faint blue. no agent tan or colorless
|
|
what color will m256a1 turn if there is blood agent
|
pink or blue, tan or colorless is neg.
|
|
what color will lewisite turn in m256a1
|
olive green, tan and colorless if neg
|
|
what color will nerve turn in m256a1
|
colorless, if blue no agent is present
|
|
how do you use m8 paper
|
blot it on liquid agents
|
|
what color will ds2 turn m8 paper
|
dark green or black
|
|
what color will caustic soda turn m8 paper
|
red false positive
|
|
what color m8 paper if there is a g nerve
|
yellow
|
|
how long must you expose the test spots on m256a1
|
10 min
|
|
how long does m256a1 take
|
15-20 min
|
|
what color will m256a1 turn if blister agent is present
|
purple or blue for mustard, red or purple for phosgene, false positive with high temps faint blue. no agent tan or colorless
|
|
what color will m256a1 turn if there is blood agent
|
pink or blue, tan or colorless is neg.
|
|
what color will lewisite turn in m256a1
|
olive green, tan and colorless if neg
|
|
what color will nerve turn in m256a1
|
colorless, if blue no agent is present
|
|
how do you use m8 paper
|
blot it on liquid agents
|
|
what color will ds2 turn m8 paper
|
dark green or black
|
|
what color will caustic soda turn m8 paper
|
red false positive
|
|
what color m8 paper if there is a g nerve
|
yellow
|
|
how long must you expose the test spots on m256a1
|
10 min
|
|
how long does m256a1 take
|
15-20 min
|
|
what color will m256a1 turn if blister agent is present
|
purple or blue for mustard, red or purple for phosgene, false positive with high temps faint blue. no agent tan or colorless
|
|
what color will m256a1 turn if there is blood agent
|
pink or blue, tan or colorless is neg.
|
|
what color will lewisite turn in m256a1
|
olive green, tan and colorless if neg
|
|
what color will nerve turn in m256a1
|
colorless, if blue no agent is present
|
|
how do you use m8 paper
|
blot it on liquid agents
|
|
what color will ds2 turn m8 paper
|
dark green or black
|
|
what color will caustic soda turn m8 paper
|
red false positive
|
|
what color m8 paper if there is a g nerve
|
yellow
|
|
what color m8 paper if there is blister
|
red
|
|
what golor if it is v nerve
|
V verde green.
|
|
what three things does m8 paper detect
|
G H V
|
|
What is m9 paper
|
chemically treated dye impregnated paper detects liquid nerve and blister agaents G V H L however identity cannot be assessed because they all turn red. like a tape dispenser, with a sticky side (like tape)
|
|
what is the difference betweet m9 paper and m8
|
m9 is more sensitive, results appear in 10 sec., its sticky tape on outside or you, but cannot differentiate inbetween agents because they all turn red. any other color is not a chem war agent.
|
|
what does CWDD
|
CHEMICAL WARFARE DIRECTIONAL DETECTOR AN/KAS 1
|
|
what is cwdd an/kas 1
|
mounted but portable unit on top of ship . infrared imagine sensor detects and identifies cw agent attack as far as sister ships, night low visibillity
|
|
what does ACADA
|
AUTOMATED CHEMICAL AGENT DETECTOR ALARM
|
|
what is ACADA
|
PORTABLE DEVICE THAT IS USED to detect cw agents during post attack surveys
|
|
what does acada detect
|
blister nerve within seconds no false positives
|
|
what are some advantages of the acada
|
light weight portable constantly tests air and gives you a reading within seconds no false positives vs m256a1.
|