ANSI/SCTE 01 2006, SPECIFICATION OF “F” PORT, FEMALE, AND OUTDOOR ARE MINIMUM REQUIREMENTS FOR WHAT?
|
F-81 INDOOR AND DROP SPLICE BARREL CONNECTORS
|
|
WHAT TYPE OF ADAPTERS (BARREL CONNECTORS) MUST ONLY BE USED FOR TEMPORARY CABLE RESTORATION?
|
F 81
|
|
WHAT DOES MECHANICAL AND ELECTRICAL SPECIFICATIONS OF ANSI/ SCTE 153 2008 REFER TO?
|
THE MINIMUM REQUIREMENTS OF ALL PASSIVE DEVICES
|
|
________ MUST HAVE NO FIELD ADJUSTMENTS OF THE CUTTING BLADES.
|
DROP CABLE PREPARATION TOOL
|
|
HOW OFTEN SHOULD THE CUTTING BLADES BE REPLACED IN A DROP CABLE PREPARATION TOOL?
|
MONTHLY
|
|
ONLY PRODUCTS APPROVED BY __________ SHALL BE USED IN THE DROP SYSTEM.
|
COMCAST CORPORATE ENGINEERING
|
|
WHAT IS THE FORWARD BANDWIDTH FOR ALL PASSIVE AND ACTIVE EQUIPMENT?
|
54 MHZ TO 1,002 MHZ (1 GHZ)
|
|
WHAT IS THE RETURN BANDWIDTH FOR ALL PASSIVE AND ACTIVE EQUIPMENT?
|
5 MHZ TO 42 MHZ
|
|
ANSI/SCTE 129 2007, DROP PASSIVE REFERS TO WHAT?
|
ALL GROUND BLOCKS MINIMUM REQUIREMENTS
|
|
WHAT WIRE SIZES DOES THE BONDING WIRE ATTACHMENT ACCOMMODATE?
|
#6 TO #14 AWG SOLID COPPER
|
|
WHAT DOES ANSI/SCTE 74 2003, SPECIFICATION FOR BRAIDED 75 OHMS FLEXIBLE RF COAXIAL DROP CABLE REFER TO?
|
THE MINMUM PHYSICAL AND ELECTRICAL REQUIREMENTS OF ALL DROP CABLE USED FOR RF SIGNAL DISTRIBUTION
|
|
WHAT DOES ANSI/SCTE 161 2009 FOCUS ON?
|
THE MINMUM REQUIREMENTS OF DROP AMPLIFIERS
|
|
DROP CABLE PREPARATION TOOLS MUST HAVE A ____ IN THE DIELECTRIC CUTTING BLADE TO PREVENT NICKING OR SCORING OF THE CENTER CONDUCTOR.
|
NOTCH
|
|
LOCKING OR SECURITY TRMINATORS MUST HAVE A ______ TO TERMINATE THE SIGNAL.
|
INTERNAL 75-OHM RESISTOR
|
|
WHAT ARE THREAD PROTECTORS USED FOR?
|
TO PROTECT THE THREAD FROM MOISTURE CONTAMINATION
|
|
WALL PLAT MUST HAVE A_______ HEX RECESS MOLDED INTO THE F-81 AND PREVENT IT FROM TURNING.
|
7/16 INCH
|
|
WHY SHOULD YOU REMOVE DROP FROM PLANT WHILE CHANGING A CONNECTOR?
|
TO MINIMIZE INADVERTENT INJECTION OF NOISE OR INTERFERENCE INTO A LIVE NETWORK.
|
|
HOW OFTEN SHOULD YOU INSPECT YOUR COMPRESSION TOOLS?
|
MONTHLY
|
|
ALL CONNECTIONS, EXCEPT THOSE ON CUSTOMER PREMISES EQUIPMENT, MUST BE WRENCH-TIGHTENED TO _____ TO ______ INCH-POUNDS.
|
30 TO 35
|
|
WHAT IS THE AIR-SHRINKABLE TUBE USED FOR?
|
INSTALLED TO COVER THE F-CONNECTOR AND FEMALE F-PORT COMPLETELY
|
|
WHEN INSTALLING A TRAP TOA JUMPER WHAT MUST BE INSTALLED ON BOTH ENDS OF THE F-81 BARRELCONNECTOR TO SEAL THE TRAP AND THE F-CONNECTOR?
|
THREAD PROTECTORS
|
|
WHAT DOES ARTICLE 820 OF THE NATIONAL ELECTRICAL CODE REFER TO?
|
THE MINMUM REQUIREMNETS OF ALL AERIAL DROPS
|
|
THIS IS REFERRED TO AS AN INTEGRAL SELF SUPPORTING STRENGTH MEMBER OF AERIAL DROP CABLE.
|
MESSENGER
|
|
WHAT TYPE OF CABLE SHOULD BE USED FOR ALL AERIAL DROPS UP TO 150 FEET?
|
SERIES 6
|
|
USING SERIES-11 FOR DROPS GREATER THAN 150 FEET WILL HELP IMPROVE WHAT TO RF?
|
FORWARD SIGNAL LEVELS
|
|
CROSSING ------------ AND UTILITY LINES WITH THE AERIAL DROP MUST BE AVOIDED.
|
SWIMMING POOLS
|
|
CABLE DROPS SHOULD NEVER CROSS _______ OUTSIDE OF THE MUNICIPAL RIGHT-OF-WAY, TO AVOID CABLE TRESPASS ________ SHOULD BE INSTALLED
|
PROPERTY LINES: MID-SPAN
|
|
WHAT IS THE CLEARANCE FROM POWER AT THE POLE?
|
40 INCHES
|
|
WHAT IS THE CLEARANCE FROM PHONE PROVIDERS AT THE POLE?
|
12 INCHES
|
|
WHAT IS THE CLEARANCE FOR POWER AT THE MID-SPAN?
|
24 INCHES
|
|
WHAT I THE CLEARANCE FOR TLEPHONE PROVIDERS AT THE MID-SPAN?
|
6 INCHES
|
|
WHAT IS THE CLEARANCE AT THE HOUSE FOR POWER?
|
12 INCHES
|
|
WHAT IS THE CLEARANCE AT THE HOUSE FOR THE TELEPHONE PROVIDER?
|
6 INCHES
|
|
WHAT IS THE CLEARANCE FOR OVER THE ROAD,STREETS, ALLEYS; NONRESIDENTIAL DRIVEWAYS
|
18 feet
|
|
WHAT IS THE CLEARANCE OVER ROADS, STREETS ALLEYS; NONRESIDENTIAL DRIVEWAYS; PARKING LOTS AND OTHER AREAS SUBJECT TO TRUCK TRAFFIC?
|
18 FEET
|
|
WHAT IS THE CLEARANCE OVER RESIDENTIAL DRIVEWAYS SUBJECT TO TRUCK TRAFFIC?
|
15 FEET
|
|
WHAT IS THE CLEARANCE OVER RESIDENTIAL DRIVEWAYS NOT SUBJECT TO TRUCK TRAFFIC ?
|
11 FEET
|
|
WHAT IS THE CLEARANCE ABOVE SIDEWALKS OR OTHER PEDESTRIAN TRAFFIC AREAS?
|
10 FEET
|
|
WHAT IS THE CLEARANCE ABOVE ROOFS NOT ACCESSIBLE TO PEDESTRIANS?
|
3 FEET
|
|
WHAT IS THE CLEARANCE FOR ALL POINTS ABOVE A FLAT ROOF?
|
10.5 FEET
|
|
HOW FAR SHOULD THE SPAN CLAMP BE SPACE FOR ANY EQUIPMENT OR HARDLINE CONNECTOR?
|
6 INCHES
|
|
HOW FAR SHOULD THE SPAN CLAMP ON EITHER SIDE OF A POLE BE SPACED FROM THE CENTER OF THE POLE?
|
30 INCHES
|
|
SPAN CLAMP MUST NEVER BE PLACE ON _____________.
|
LASHING WIRE; TO PREVENT DAMAGE, A CABLE GUARD MUST BE OVER CABLE
|
|
HOW MUCH CLIMBIMG SPACE FROM THE CENTER OF THE POLE MUST BE MAINTAINED AT ALL TIMES?
|
30 INCHES
|
|
WHEN ATTACHING THE DROP CABLE TO THE OPPOSITE SIDE OF THE POLE FROM THE TAP, A MINIMUM _______ DRIP LOOP HALF CIRCLE MUST BE LEFT FROM THE DROP CABLE GRIP TO THE STRAND.
|
5-INCH-DIAMETER
|
|
WHY SHOULD DROP CABLE NEVER BE TIED TO THE TOP SIDE OF THE STRAND OR POLE HARDWARE?
|
TO PREVENT SQUIRRELS CHEWING THE DROP
|
|
WHAT IS THE METHOD TO TIE OFF THE MESSENGER WIRE?
|
2-4-4
|
|
WHAT IS THE MINIMUM AMOUNT OF INCHES OF SAG FOR EVERY 50 FEET IN LENGTH IF THERE IS NO POWER REFERENCE?
|
6 INCHES
|
|
HOW SHOULD THE MID-SPAN ATTACHMENT BE INSTALLED?
|
FRIOM THE POLE TO THE MID-SPAN POINT AND THEN TO THE HOUSE
|
|
MULTI-SPAN CLAMP MUST ONLY BE ATTACHED TO THE _______.
|
STRAND
|
|
WHAT SHOULD BE PLACED BETWEEN THE DISTRIBUTION CABLE AND THE MULTI-SPAN CLAMP TO PREVENT CABLE DAMAGE?
|
CABLE GUARD
|
|
WHAT SHOULD BE PLACED ON EVERY DROP?
|
DROP ADDRESS AND SERVICE TAG
|
|
WHERE ARE TRAPS PROHIBITED FROM BEING PLACED AND WHY?
|
DIRECTLY ONTO THE TAP, BECAUSE IE MAY CAUSE PORT DAMAGE
|
|
WHEN PLACING A TRAP ON THE LINE YOU MAKE SURE MINIMUM _________ OF THE DROP IS MAINTAINED AT ALL TIMES.
|
BEND RADIUS
|
|
ALL UNDERGROUND DROPS MUST MEET THE MINIMUM REQUIREMENTS OF WHAT ARTICLE?
|
ARTICLE 820 OF THE NATIONAL ELECTRICAL CODE (NEC)
|
|
WHAT TYPE OF MATERIAL IS THE UNDERGROUND CABLE JACKET MADE OF?
|
POLYETHYLENE
|
|
WHAT LAWS SHOULD THE UNDERGROUND BORES BE IN COMPLIANCE WITH?
|
LOCAL, STATE, AND NATIONAL
|
|
WHAT IS THE MINIMUM BURY DEPTH FOR NEW INSTALLAION OF UNDERGROUND DROPS IN CONDUIT?
|
12 INCHES
|
|
FOR AN EXISTING INSTALLATION, AND WHEN NOT COMPLETELY IN CONDUIT, WHAT IS THE MINIMUM BURY DEPTH FOR UNDERGROUND DROP?
|
8 INCHES
|
|
WHERE SHOILD UNDERGROUND CABLE NEVER BE ROUTED?
|
ACROSS PROPERTY LINES, THROUGH THE LIDS OF THE PEDESTAL AND ANY GARDEN SPACE
|
|
HOW SHOULD UNDERGROUND DROPS BE ROUTED?
|
THE SHOREST ROUTE POSSIBLE
|
|
WHEN RUNNING UNDERGROUND DROPS PARALLEL TO LOT LINES, HOW MANY FEET AWAY FROM THE LINES BE ROUTED?
|
4 FEET
|
|
UNDERGROUND DROPS MUST EXTEND A MINIMUM OF _______ INCHES ABOVE TAP AND_________ INCHES PAST THE GROUNDBLOCK AT THE HOUSE.
|
12INCHES; 12INCHES
|