These are good safety precautions to follow when charging a battery (3 of them).

1. never charge a frozen battery or one with damaged plates.




2. Always wear safety glasses.




3. Make sure area is well ventilated.

True or False about the conclusion of a battery load test - the battery should be charged and recharged because it dropped below 9.6 volts and rose about 12.4 volts when the load was removed.

FALSE

While conducting a battery drain test, if the ammeter reads ____ or more amperes, there is excessive drain.

.250 or more

How many volts are present in a fully charged 12-volt battery?

12.6 VOLTS

What is the first step in removing an old battery?

Inspect and Clean the area

Corrosion on or near the battery must be minimized because _____ (3 answers)

1. Corrosion can destroy the hold-down straps and battery tray.




2. Corrosion can create a path that will allow the battery to slowly discharge.




3. Corrosive on the battery terminals increases resistance in the battery circuits.

A Cold-Cranking amperes (CCA) rating specifies the minimum amperes available at _____ degrees Fahrenheit.

0 degrees

the best way to test battery cables and terminal for excessive resistance is by ___ testing?

VOLTAGE DROP

A conductance tester measures the battery condition by _________

Sending a small AC signal through the battery and measuring the current response.

Which one is NOT part of the Battery Cell?


Electrolyte, Solenoid, Positive Electrode


Negative electrode

Solenoid

When load testing a battery, the load applied to the battery should be ___________.

1/2 the CCA rating

When Charging a battery that has been completely discharged, the most important item is to monitor the ____.

Battery Temperature

Which method of testing for battery state of charge (SOC) can be used on maintenance-free batteries?

BOTH Built-In Hydrometer and Open Circuit Voltage test

What can cause battery over charging?

BOTH a faulty vehicle charging system and Improper use of a battery charger

This is NOT a common cause of premature battery failure?

Increased Cycling

Technician A uses a solution of baking soda and water to clean a battery - Technician B uses soap and water. Who is correct?

Technician A is CORRECT

Technician A says the specific gravity of pure water is 10.00 at 80 degrees F. - Technician B says the specific gravity of electrolyte in a fully charged battery is between 1.260 and 1.280 at 80 degrees F. Who is correct?

Technician A is CORRECT

Technician A says the reserve capacity rating of a battery is the amount of steady current that a fully charged battery can supply for 20 hours without voltage dropping below 10.5 volts - Technician B says an ampere-hour rating states how many hours the battery is capable of supplying 25 amperes.

Technician A is CORRECT

NONE

none