API 653 covers which of the following types of tanks?

Carbon and low alloy steel tanks built to API - 650 and 12c.

API 653 paragraph 1.1.1

API 653 provides the requirements for construction of which of the following?

This standard does not provide construction requirements.

API 653 paragraph 1.1.1

API 653 provides for all but which of the following with regard to aboveground storage tanks?

Operation

API 653 paragraph 1.1.1

The scope of API 653 is limited to all of the following except?

Tank mixing motor

API 653 paragraph 1.1.2

The API 653 standards states that many of the requirements for design, welding, and materials of API 653 and API 12c can be applied with regard to?

Repair, inspection, rating, and alteration.

API 653 paragraph 1.1.2

In the application of the requirements for welding, design, and materials of API 650 or API 12c to in service aboveground storage tanks (AST), which of the following code or standard takes precedence?

API 653

API 653 paragraph 1.1.2

The API 653 standard may only be applied to aboveground storage tanks (AST) that have been constructed to and meet the requirements of API 650.

False

API 653 paragraph 1.1.3

The use of API 653 is intended for organizations that have personnel who are technically trained and experienced in which of the following?

Tank desig, fabrication, repair, construction, and inspection

API 653 paragraph 1.1.4

When design and construction details are not given and not available in the as built standard, details that will provide a level of integrity equal to the current edition of what Code or Standard must be used?

API 650, Welded Steel Tanks for Oil Storage

API 653 paragraph 1.1.5

Ultimate responsibility for compliance with this standard rests with?

The Owner/Operator