• Shuffle
    Toggle On
    Toggle Off
  • Alphabetize
    Toggle On
    Toggle Off
  • Front First
    Toggle On
    Toggle Off
  • Both Sides
    Toggle On
    Toggle Off
  • Read
    Toggle On
    Toggle Off
Reading...
Front

Card Range To Study

through

image

Play button

image

Play button

image

Progress

1/18

Click to flip

Use LEFT and RIGHT arrow keys to navigate between flashcards;

Use UP and DOWN arrow keys to flip the card;

H to show hint;

A reads text to speech;

18 Cards in this Set

  • Front
  • Back

What is the expected HYD pressure when powered by the RAT?

2500 PSI

When will the PTU turn on automatically

When differential HYD pressure between green and yellow system is greater than 500 PSI

How can you close the HYD Fire shut off valve?

By pushing the corresponding ENG FIRE pb

Where does the air that pressurize the HYD reservoirs come from?

HP bleed from ENG 1, cross bleed duct if pressure is low. (What if no bleed at all?)

PUMP fault light comes on for

Reservoir low level


Reservoir overheat


Reservoir low air pressure


Pump pressure is low, for all these, once turn off, fault light goes out.



Pump Overheat, fault light stays on for the duration of the overheat even if turned off

The RAT will deploy automatically if

Both AC BUS 1 and AC BUS 2 is lost

The PTU is inhibited during

First engine start and tested after second engine start. PTU is also inhibited for 40s after end of cargo door operation.

On the ECAM HYD page, the low level ranges represents how much volume?

Green / Blue / Yellow


3.5L / 2.4L / 3.5L



Associated with RSVR LO LVL ECAM caution

On the ECAM HYD page, what volume does the range of normal filling represent?

Green / Blue / Yellow


2.6L / 1.6L / 2.6L

On the ECAM HYD page, what is the volume of total fluid represented by the top of the normal fill range?

Green / Blue / Yellow


14.5L / 6.5L / 12.5L

On the ECAM HYD page, amber triangle with the RAT represents

Pressure for stowing the RAT has been applied, or


RAT Pump is not avbl.



Associated with ECAM HYD RAT FAULT

In terms of ECAM caution, at what pressure will SYS LO PR and PUMP LO PR comes on?

ENG pumps: 1750 PSI (reset @ 2250 PSI)


ELEC pumps: 1450 PSI (reset @ 1750 PSI)



SYS LO PRESS: 1450 PSI

When will RAT OUT memo be shown in AMBER?

RAT is not fully stowed and during flight phase 1 and 2 (ELEC PWR to 1st ENG T/O PWR)

What does ECAM HYD PTU FAULT mean?

Differential pressure is above 650 PSI


On ground: PTU not running


Inflight: PTU still at AUTO when G&Y LO LVL or Y LO PR

If HYD G/Y LO LVL, OVHT, LO AIR PR, the PTU will overheat after how long if not switched off according to ECAM?

2 minutes

According to SOP, a PUT fault is triggered if the second engine is started within 40s follow the end of the cargo doors operation, how to you fix it?

Reset the warning by switching the yellow ELEC pump ON, then OFF



PUT is inhibited for 40s after end of cargo door operation, but also tested during 2nd engine start, the 2 actions perhaps creates a conflict hence causing the fault.

What is the threshold for HYD RSVR LO AIR PR caution?

321: Air pressure <= 22 PSI, reset @ 25PSI


320: Air pr <= 22 PSI, reset @ 25PSI


In addition B RSVR <= 30PSI will also also trigger ECAM on ground after landing

At what temperature will HYD RSVR OVHT comes on?

93C, reset @ 88C