When will flap load relief activate?

Arms at flaps 20° and will activate when at flaps 25° or 30° and overspeeding the flaps.

When will the TRAILING EDGE light illuminate?

-Disagree between handle position and flap position.


-Flap asymetry


-Fault in load relief system (not relieving)

SPEEDBRAKES light means what?

Speedbrakes are out when:


-Thust levers are not idle


-Below 800' agl


-Landing flaps selected

What do the yaw dampers need to function?

Electrical power


Hydraulic power


A functioning IRU

What system does the PES run on?

Uses Right hyd system pressure and trapped Left hyd system fluid to trim the stab at 1/4 rate. Utilizes normal electric (yoke) trim.

What is aileron lockout?

The outboard ailerons are locked in a neutral location during high speed regimes of flight.

What does the AIL LOCK light mean?

That the lockout system has either failed to lockout the outboard ailerons, or that the outboard ailerons are locked out when they shouldn't be. You will still have control.

What things are dependent on nose wheel extension?

-Stall warning system


-Master warning inhibits


-From 80kts, Master Caution inhibits

If an emergency exit is opened, what will happen?

-Emergency lights will illuminate


-Inboard spoiler will stow, for the slide

What hydraulic system is the Stab Trim on?

Left hydraulic system

What hydraulic systems are the elevator feel units connected to?

Left and Center

If the RUDDER RATIO light is on, what does it mean?

That rudder protection is no longer being provided and the left hydraulic actuator is depowered. Crosswind limit 15kts.

The AUTO PILOT light illuminates under what condition?

When there is a failure or degraded condition with the selected autopilot. If failure is common, the light will not extinguish.

What are the AUTOLAND crosswind limits?

CAT I = 25kts


CATII/III = 15kts

During alternate flap extension, is asymmetry protection provided?

For the Leading edge only.