 AFFF is the primary extinguishing agent for a ____ class fire.

Bravo

 AFFF piping is painted ...

green with red stripes.

 Each AFFF station has a _____ gallon tank made of 90% copper- 10% nickle

2000

 Each AFFF station has a 2000 gallon tank made of ...

90% copper- 10% nickle

Percentage and metal

The tank is filled with AFFF concentrate and will last approximately ____ minutes under continuous use.

30

 AFFF is diluted with sea water at a ratio of ____% sea water to ____% AFFF

94, 6

Very high and very low

In each AFFF station there are TWO balance proportioners and TWO ___ gpm pumps

65

The _______ will only proportion the amount of AFFF concentrate necessary to produce a satisfactory AFFF/water solution over a wide range of flows and pressures.

balance proportioner

 AFFF pumps send the AFFF to the ...

proportioner

There are different ways to activate AFFF. They are ...

-from each push button (for hose reel and sprinkler)


-DCC


-the SOPV


-and from the motor controller in the station.

 Each AFFF station on board has ______. These are used for emergencies where AFFF may not be able to get to a certain space, hoses can be ran from the station to the space.

Emergency Hose Connection fittings

The emergency hose connection fitting is a ______ fitting.

1 1/2in

Size

 WASP’s AFFF system is broken up into groups and zones. There are ___ groups and ___ zones.


30, 12

______ are sectioned areas where sprinklers can be activated with out activating the entire system.

Groups

Groups are activated by their ...

SOPV (Solenoid Operated Pilot Valve) or from DCC.

The _______ is an electrically operated pilot valve that will activate the AFFF station and send AFFF to that specific group.

SOPV (solenoid operated pilot valve)

 Zones are the same as group’s except that zones are ...

outside the skin of the ship, where as groups are inside the skin of the ship

There are AFFF hard rubber hose reel’s placed strategically around the ship. Most of these hoses are located on the ....

-flight deck


-hangar bay


-machinery spaces

There are ____ in the machinery spaces to activate the hose reels,

push button

 The balancing valve is a diaphragm-type hydraulically operated globe regulating valve. It is installed in the re-circulation line of balanced-pressure systems between the ...

concentrate pump discharge and the AFFF service tank.

This valve is used to regulate the amount of AFFF being sent by detecting the water pressure.

Balancing valve

Any fluctuation in the ______ will change the amount of AFFF being sent

water pressure and the balancing valve

The Power-Check is a diaphragm type, hydraulically operated globe control valve. Inside the valve are 2 stem’s. The _____ stem is used as a check valve, closing when any back pressure is detected.

Bottom



(Bottom; back pressure)

The Power-Check is a diaphragm type, hydraulically operated globe control valve. Inside the valve are 2 stems. The _____ stem is an indicator if the valve is open or closed.

Top

The Hy-Check valve is essentially the same as a power-check valve. The difference is that the Hy-Check valve controls ....

the stations firemain, opening and closing is done using the SOPV.

______ keeps pressure on your Hy-Check valve. With out the ______, the system would activate.

M-81 Check valve

The WASP is equipped with a type ____ “Balanced Pressure Proportioning System”.

III

When manning an AFFF station, you must have comm’s with Damage Control Central (DCC) using the ...

X50J

AFFF stations can be started from DCC but can only be secured from ...

the station.

There are ____ AFFF stations aboard WASP

6

All AFFF stations are located on the...

Main deck

Since all the AFFF stations aboard are attached to ______, if one station runs out of AFFF, another station can be activated and continue sending AFFF to the space.

the same loop

WHAT IS AN “ABT” AND WHATS ITS PURPOSE?

automatic bus transfer units




transfer power from SSTG’s (Ship’s Service Turbine Generators)to EDG’s (emergency Diesel Generators) in case of power failure.

(T/F) TO REPLENISH A AFFF TANK ONBOARD WE ALLIGN A 360GPM TRANSFER PUMP?

false

WHAT 2 VALVE ARE CONTROLED BY THE MASTER SOPV?

POWERCHECK/HYCHECK

AFFF #1 is located...

All the way forward, stbd side by the lighting shop.



(1 = l )

AFFF #2 is located...

Just fwd of the the deck office ladderwell


(Deck office = 2 words)

AFFF #3 is located...

Double wide p-way.


(3 words, 3 comes after 2)

AFFF #4 is located...

Just above the oil lab.



(JOAP has 4 letters)

AFFF #5 is located...

Aft, stbd side of the hanger bay by repair locker 3.

AFFF #6 is located...

Mid ships, hanger bay, port side fwd of 1H.

How many groups are there?

30

How many zones are there?

12

The AFFF system provides water and AFFF mixed in a 94:6ratio to _________ located throughout the ship.

hose reels


bilge sprinkling systems


and hanger deck sprinkling systems

AFFF protected spaces include ....

main machinery spaces, vehicle stowage spaces, hanger bays, fuel pump rooms, and other locations prone to “B” fires

DC Deck Re-Entry Hose Reels are _____’ Non Collapsible ____ inch rubber hose with 95 GPM vari-nozzle

125, 1 ½

(DC Deck Re-Entry Hose Reels) Hose reel cut out valve is NORMALLY...

CLOSED

Engineering space hose reels are ____’ non-collapsible ____ inch rubber hosewith 95 GPM vari-nozzle

50, 1 ½

(Engineering space hose reels) Hose reel cut out valve locked ....

open

Concentrate pump: _____ - moves AFFFfrom tank to ratio controller

positive displacement pump

Concentrate pump: vital load, equipped with an ...

ABT and MBT

Fire Main valves are colored...

RED

AFFF Finished foam mixture valves are colored...

RED/GREEN

AFFF Concentrate valves are colored...

RED/BLUE

•______ SOPV (Solenoid Operated Pilot Valve)–activatedremotely by push button; activated locally manually

Master

–controlsoperation of Hycheck and Powercheckvalves

Master SOPV

–activatedremotely by push button; activated locally manually

Service SOPV

–controlsoperation of Powertrolvalve

Service SOPV

–AFFF is EXTREMELY...

corrosive

–Ensure system is properly _____ following each use

aligned

–AFFFCREATES A _____ OVER THE FUEL!

VAPOR SEAL

–Some formation/collection of ______ mayoccur is piping/areas where AFFF stands stagnant for a period of time

H2S

–Avoid inadvertent contact with ______ equipment while using AFFF

electrical

USS Wasp has a Type 3 ...

BPPS Balance Pressure Portioning System

USS Wasp has ___ groups and____ zones. Groups are located inside the skin of the ship, zones are locatedoutside/flight deck

30 , 12

AFFF is the primary agent for Class ____ fires

Bravo

Class B Fires Do Not Leave Any Ashes, ButProduce ______ Smoke

Black

Whatdoes AFFF do?

It creates A Vapor Seal, Separating The Fuel And Associated Free Radicals From The Air Above It. Also Contains Concentrate Mixed With Saltwater, Adding A Cooling Element.

Musthave comms with DC central, the DC sound powered phone circuit for all AFFFstations is the ...

X50J

Theemergency hose connection for AFFF inside the station is ___ inch hoseconnection

1 ½

Alpha and Bravo Pumps are rated at ___ GPM

65

Type of pump is a ...

positive displacement sliding vane