Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
3 Cards in this Set
- Front
- Back
Engine starting limitations |
During starting if the engine does not reach 58% N1 in a total time of 45 seconds (60 seconds below 10°C), close the throttle and press the starter button until the TOT is below 200°C. If engine fails to start on third attempt, abort start and make an entry on DA form 2408-13-1.
Engine starter limitations do not apply to engine starting limitations should an abort start become necessary. |
|
Fuel boost pump failure warning |
Operation with both fuel boost pumps inoperative is not authorized. Due to possible fuel sloshing in unusual attitudes and out of trim conditions and one or both fuel boost pumps inoperative, the unusable fuel is ten gallons. |
|
Fuel boost pump failure note |
With one or both fuel boost pumps inoperative: NOTE The engine will operate without boost pump pressure under 6,000 feet pressure altitude and one boost pump will supply sufficient fuel for normal engine operations under all conditions of power and altitude. Both fuel boost pumps shall be operating for all normal operations. a. Descend to below 6,000 feet pressure altitude if possible. b. Land as soon as practicable. |