Primary Clarifiers remove ____ to ____% Inf BOD

20% to 40%

Primary Clarifiers remove ___% (TSS) Inf solids.

50%-70%

Nitrification is stopped at what temperature?

5-10 degrees Celsius

Strong BOD domestic wastewater concentration is_____mg/l.

350-500 mg/l

Normal domestic BOD concentration is ___mg/l.

200-250 mg/l

Normal running anaerobic digesters reduce___ to__% solids.

50%-60%

Methane Fermenters need a PH of ____ to properly reproduce.

6.6 - 7.6

Primary Clarifiers remove ____% settlable solids.

95%-99%

Nitrification and Denitrification have a PH of ___ to__to run properly.

7.8 - 8.2

Normal anaerobic digesters have a ___ to___% methane content by volume.

65% - 70%

A typical MLSS concentration in the Activated Sludge Process is ____mg/l.

1000 - 4000 mg/l

It's safe to work a 40 hour work week with a chlorine gas exposure of ___ppm.

0.5 ppm

Chlorine gas is_____times heavier than air.

2.5

Typical BOD removal in a Facultative Pond is____ to ___%

70% - 80%

Typical Detention Time in a Primary Clarifier is _____hrs.

1.5 - 2 hrs

Normal anaerobic digestion has a carbon dioxide content of ___% by volume.

30% - 35%

Entering a confined space is oxygen deficient when it is ___%.

<19.5%

Typical bacterial removal in a Primary Clarifier is ____ to___%.

25% - 75%

Domestic raw wastewater has a PH of___ to ___.

6.8 - 8.0

Typical suspended solids removal in a Primary Clarifier is ____ to ____%.

40% - 60%

Typical MLSS concentration is usually ______mg/l.

1000 mg/l to 4500 mg/l

Typical BOD concentration in a secondary clarifier is __to__mg/l.

5 - 30 mg/l

Good, thick primary sludge is __ to__% dry solids.

4% - 8%

Grit will properly settle at what speed?

1 ft/sec

Sedimentation Basins have a settleable rate of ____hrs.

2- 3 hrs

WAS rate shouldn't change more than _____% from one day to the next?

10% - 15%

MLVSS and MLSS ratio in an ASP should be between ______.

0.7 and 0.8

There are _____U.S. gallons in a cubic ft.

7.48

7.48 U.S. gallons per cubic foot is equivalent to ______ lbs/gal.

8.34

Generally, specific gravity of municipal sewage lies between _____.

1.2 and 1.4 --- which is slightly greater than 1

1 ppm of dissolved oxygen in water equals ___lb of oxygen in ___lbs of water.

1lb, 1,000,000 lbs

A number used in horsepower math is _____.

3960

An Acidic PH range is ________.

0 to 6.9

A Basic PH range is______.

7.1 to 14.0

Typical dissolved oxygen in an aeration tank is ______mg/l.

2 - 4 mg/l.

MLVSS should be between _______ % and______% of the MLSS.

70% and 80%

Maintain a dissolved oxygen concentration of _____mg/l or higher for optimum nitrification.

2.0 mg/l

PH below _____ or above ____ can inhibit nitrification.

6.5, 8.0

Maintain a dissolved oxygen concentration below _____mg/l in an anoxic zone to achieve denitrification.

0.3 mg/l

1 gallon equals _____lbs.

8.34

1000 mg equals ____ ml.

1

There are ______ mg in a gram.

1000

There are ______ml in a liter.

1000

In process control, don't make incremental changes that exceed _____%.

10%

Sludge pumps are sized to pump _____% of plant flow.

100%

Sludge Bulking leaves a clear supernatant, but the SVI is high; usually greater than ______mg/l.

150 mg/l

When using specific gravity,"dry feed" is what % of the solution?

100%

A good anaerobic digester reduces volatile solids by_____%.

50% - 60%

Chlorine gas isn't detected by smell if concentration is:

<1PPM

Water expands as temperatures _________ above_________.

Increase, 4 degrees Celsius

What is the wastewater velocity range in ft/ sec for grit removal in a grit chamber?

0.7 to 1.4 ft/sec

In domestic wastewater, suspended solids range from ____ to ____mg/l.

100 to 300

In general, the solids content in wastewater is about _____%.

0.1

What is the typical BOD removal in a Primary Clarifier? (%)

20 - 50%

For each ft of height of a water column, the pressure increases______psi.

0.433

Each ____ ft of elevation of a column of water generates 1.0 psi.

2.31

Horsepower equals _____ ft-lbs/sec.

550

1 horsepower equals _____ watts or _______ kilowatts.

746, .746