What are the dimensions of the CFA Heavy Pumper?


(Height, Width, Length, Weight and Turning Circle)

Height: 3.35m


Length: 8.15m


Width: 2.5m (3m with Mirrors)


Weight: 13.2T Operational/ 18.6T Gross


Turning: 15.5m Curb to Curb

What are the tank capacities of Fuel, Water and Foam tank?

Diesel 200L


Water 2000L


Foam 200L

What pump is on the appliance and what is the rated capacities? (Low Pressure, High Pressure & Max Flow)

Godiva WTB-4010 Rear amounted Multi stage pump




Low Pressure: 4000L/min @ 1000kPa & 3m Lift


High Pressure: 750L/min @ 5500kPa


Max Flow: 6200L/min

What type of roof monitor is on the appliance? Including Pressure and Flow (min to max)

TFT Hurricane


700kPa Optimal Pressure


600 - 4700 L/min

What ground monitor is on the Mills Tui Heavy Pumper? Including Pressure and Flow (min to max)

Protek


700kPa Optimal Pressure


360 to 950 L/min

What are the 38mm, 64mm and High Pressure Branches? (Type, Optimum PRessure, Flow Rates)

- Protek 366 38mm: 700 kPa; 115, 230, 360, 475L/min


- Protek 368 64mm: 700kPa; 360, 475, 550, 750, 950L/min


- Akron 1702 HP: 60m Reel, 3000kPa, 50-230 L/min

What is the foam branch and its flow rate?

Angus 450 Foam Branch


450 L/min


700 kPa

What type of primer is on the vehicle? (Including Activation and run time)

- Positive Displacement Twin Piston Primer


- Automatically activates when pressure drops below 150 kPa


- 30 seconds maximum run time

4 uses of the Mills Tui Heavy Pumper?

Convey crew of up to 5 operational personnel including the necessary equipment to the fire ground in an urban environment.


Pump water from a static supply, street mains, or via the on board first aid tank.


Produce B class foam from the on-board tank supply or external source to all deliveries including hose reels, or via the inline inductor to a single hose line.


To pump from tank supply utilising the main and second stage pumps with high pressure hose reels..

What fitted and auxillary foam system is on the appliance?

Fitted: Feecon Around the Pump Proportioner with a metering range of 0 - 10


Auxiliary: Angus 450 Foam Inline Inductor and Branch with metering range of 3%, 6%, 3%AR and 6%AR

  Transmission Warning Light
What is is and what actions do you take? 

Transmission Warning Light


What is is and what actions do you take?

Activated when the transmission oil temperature is too high.


Actions: 1) Reduce engine speed


2) Stop the vehicle if necessary


3) Select Neutral


4) Raise Engine RPM until light goes off


5) Notify the DMOs

What are the visual and audible low water indicators and when do they activate/deactivate?

Visual: Amber Strobe on Rear Roof & Indicator light in cab. Activated when first aid tank level drops below 1/4 and deactivates when it returns above 3/4.


Audible: When tank falls below 1/4 and sounds for 5 seconds.

What are the built in pump protection systems?

Pressure: Pressure relief valve between the high and low pressure stages of pump.


Thermal: Recirculation valve to allow water to flow through the pump back to the tank


Thermal: Thermal relief valve operates at 42 degrees, releasing water onto the ground.


Caviatation: Pump governor will drop RPM to idle when the increase in RPM causes a decrease in pressure.


Caviatation: Priming pump will automatically prime with the pressure drops below 150kPa.